At what relative humidity is air considered saturated?
50%
100%
75%
90%
What is specific humidity?
Ratio of water vapor mass to total air volume
Ratio of water vapor mass to the mass of dry air plus moisture
Difference between dry bulb and wet bulb temperatures
The same as absolute humidity
What does a psychrometer measure?
Air pressure
CO₂ levels
Humidity using dry and wet bulb thermometers
Wind speed
What is a sling psychrometer?
A device for measuring wind speed
A psychrometer that can be rotated through the air
A digital humidity sensor
A pressure-sensitive moisture meter
What is the dew point?
Temperature at which evaporation stops
Temperature at which air is saturated and condensation begins
Temperature at which relative humidity is 50%
The difference between wet bulb and dry bulb temperatures
What does a thermohygrometer measure?
Only humidity
Humidity, temperature, and pressure
Air velocity
Condensation rate
What material is used in a dew cell?
Silver
Lithium chloride
Copper sulfate
Sodium bicarbonate
What is the function of a recording psychrometer?
Measures temperature
Records humidity over time
Measures wind speed
Determines air pressure
What is a hygrometer?
Device for measuring air pressure
Instrument that measures humidity changes in materials
Tool used for recording wind direction
A type of temperature gauge
What is a hygroscopic material?
A material that repels moisture
A material that absorbs and retains moisture
A material that only absorbs gases
A material that does not change with humidity
What is a solids moisture analyzer used for?
Measuring the pH of water
Detecting gas emissions
Measuring moisture in solids
Determining soil composition
How does a near-infrared (NIR) moisture analyzer work?
By measuring temperature differences
By measuring reflectance of the process material
By detecting sound waves in a material
By weighing the material before and after drying
What does reflectance depend on?
Air pressure
The weight of the material
Chemical composition, moisture content, and surface texture
The shape of the object
What is a microwave moisture analyzer?
A device for measuring sound waves
A device that detects changes in air pressure
A device that measures moisture content using microwaves
A device for determining oxygen concentration
At what wavelength does water absorb microwaves?
500 mm
122 mm
10 mm
250 mm
What is gravimetric moisture analysis?
Measuring moisture with infrared sensors
Measuring moisture by weight loss due to evaporation
Measuring moisture with microwave technology
Using sound waves to determine moisture content
How does an electrical impedance moisture analyzer work?
Measures moisture content based on conductivity
Uses infrared reflectance to determine moisture
Measures weight changes due to evaporation
Detects radio waves in moist materials
What does a nuclear solids moisture analyzer measure?
Air pressure changes in a solid
The temperature of a solid
The speed of neutrons in a moist material
The density of a solid
What type of moisture analyzer works based on neutron speed?
Nuclear solids moisture analyzer
Microwave moisture analyzer
Infrared moisture analyzer
Electrical impedance moisture analyzer
Why is moisture measurement in solids important?
It affects the texture of materials
It impacts the weight of the material
It is crucial for mass production of granular materials
It prevents color changes in materials
What is the key characteristic of a material measured using a microwave moisture analyzer?
Its density
Its ability to absorb microwaves
Its ability to reflect infrared radiation
Its resistance to humidity
What is the primary advantage of using a digital thermohygrometer?
It is more portable than a sling psychrometer
It requires manual calibration
It calculates multiple humidity-related properties automatically
It only measures dry bulb temperature
A(n) sample is a sample from a process in which the composition of the sample is the same as in the process piping.
intermittent
Condensable vapor
Representative
Coalescing
Process
Analyzers that process samples have lag times too long for conventional control methods.
Intermittent
Continuous
Conditioned
Unconditioned
Noncontinuous
The thermal conductivity analysis method can only be used for gases with widely different thermal conductivities.
Binary
Condensable
Heated
Cooled
Conductive
An analyzer is a radiant-energy absorption analyzer consisting of an IR electromagnetic radiation source, an IR detector, and two IR absorption chambers.
Nondispersive infrared
Ultraviolet
Paramagnetic oxygen
Thermal conductivity
Opacity
materials are repelled by a magnetic field.
Diamagnetic
Paramagnetic
Hygroscopic
Hydroscopic
Electromagnetic
A measures an electric current generated when the analyzer is subjected to different oxygen concentrations on opposite sides of an electrode.
pH analyzer
Humidity analyzer
Microwave moisture
Photoacoustic detector
Zirconium oxide oxygen analyzer
is the ratio of the actual amount of water vapor in the air to the maximum amount of water vapor possible at the same temperature.
Relative humidity
Absolute humidity
Humidity ratio
Saturation
Specific humidity
is the ambient air temperature measured by a thermometer that is freely exposed to the air but shielded from other heating or cooling effects.
Specific humidity
Saturated air
Wet bulb temperature
Dry bulb temperature
Absolute humidity
A is a humidity analyzer that measures the physical or electrical changes that occur in various materials as they absorb or release moisture.
hydrometer
hygrometer
Sling psychrometer
Ultraviolet analyzer
Opacity analyzer
A is a combination of a hygrometer, pressure sensor, and temperature-sensing instrument.
Electromagnetic analyzer
diamagnetic analyzer
Thermoparamagnetic analyzer
Paramagnetic analyzer
thermohygrometer
The hygrometer is the device for measuring liquid density.
Simplest
Largest
Hardest
Smallest
Highest
As the density of the fluid in a vibrating U-tube density analyzer changes, the of the U-tube changes.
temperature curve
tube length
Resonant vibration frequency
Float position
tube weight
A inside the float, which is also used as weight, acts as a variable coupling to a set of external electrical coils.
Metal rod
specific gravity
Temperature
Absolute viscosity
specific humidity
viscosity is the ratio of absolute viscosity to fluid density and has units of centistokes (cS).
Newtonian
Saybolt
Kinematic
Rotating spindle
Liquid
A _ analyzer measures the amount of suspended solids in a liquid by the measurement of light scattering from the suspended particles.
Turbidity
Refractive index
Flotation
Viscosity
Opacity
Conductivity measurement is much more complex at higher concentrations because the response may become very _.
Linear
Nonlinear
Erratic
Bufffered
Unpredictable
A (n) _ is a graph that shows the quantities of reagent required to change the pH of a solution.
Buffered solution
Unbuffered solution
Oscillator
Titration curve
Reaction graph
A _ analyzer is an electrochemical analyzer consisting of a cell that generates an electric potential when immersed in a sample.
pH
Newtonian
Horizontal
Slightly sloped
Voltage
A (n) _ is the modern unit of electrical conductivity and is the reciprocal of resistance.
mho
ampere
Siemens
Volt
Ohm
A _ is a liquid analyzer consisting of an instrument where a measured quantity of a process sample is mixed with precise quantities of reagents and then quantitatively measured with a pH meter or by a colorimetric or other type of detector.
Titration curve
Viscosity analyzer
Turbidity analyzer
Titration curve
Conductivity meter
Wet bulb temperature is the highest temperature that can be obtained through the heating effect to water evaporating into the atmosphere.
True
False
A _ psychrometer consists of two glass thermometers attached to an assembly that permits the two thermometers to be rotated through the air.
Sling
Recording
Hygrometer
Double
Fixed
_ is the ratio of the actual amount of water vapor in air to the maximum amount of water vapor possible at the same temperature.
Relative humidity
Specific humidity
Kinematic humidity
Absolute humidity
Partial humidity
A dew cell is a fiberglass cylindrical core impregnated with lithium chloride and wrapped with a winding of gold wire around the core that serves as a _ element.
Recording
Fixing
Cooling
heating
Measuring
A thermohygrometer is a combination of a hygrometer, pressure sensor, and temperature-sensing instrument.
True
False
Absolute humidity is another name for humidity ratio.
True
False
A _ is a humidity analyzer that measures physical or electrical changes that occur in various materials as they absorb or release moisture.
Sling psychrometer
Hygrometer
Recording psychrometer
Dew cell
Wet-bulb hygrometer
_ humidity is a ratio of mass water vapor to the mass of dry air plus moisture.
Absolute
Relative
Specific
None of the above
Calculated
_ is the amount of water vapor in a given volume of air.
density
humidity
Buoyancy
Saturation
Vapor pressure
_ are the band of electromagnetic radiation between infrared and VHF broadcast frequencies, covering the range of approximately 3 mm to 3 m wavelengths.
Microwaves
Radiowaves
Ultraviolet waves
Gamma rays
Infrared waves
Water absorbs microwaves at a wavelength of approximately _.
132 mm
142 mm
112 mm
102 mm
122 mm
A hygroscopic material is a material that readily absorbs and retains moisture with _ in humidity and releases moisture with _ in humidity.
Increase-decrease
Decrease-increase
Constant-change
Rapid-slow
Slow-rapid
_ is a temperature to which air must be cooled for the air to be saturated with water and any further cooling results in water condensing out.
Dew cell
Microwave
Saturated air
Dewpoint
Condensation point
_ is the ability of a material to reflect light or radiant energy.
Reflectance
Admittance
Transmittance
Temperature
Luminescence
_ is a simplest device for measuring liquid density.
Thermohygrometer
Hygrometer
Hydrometer
Thermohydrometer
Density meter
A (n) _ moisture analyzer is an analyzer that measures the amount of moisture in solids by measuring the speed of neutrons that strike the object.
electrical impedance
nuclear solids
Microwave
Radiowave
Infrared
A near infrared moisture analyzer is a solids moisture analyzer that measures the _ of the process material and calculates moisture content.
Transmittance
Temperature
Reflectance
Admittance
Absorbance
_ is a liquid that contains suspended solids that are heavier than the liquid.
Slurry density
Slurry
Newtonian liquid
Non-Newtonian liquid
Suspended solution
_ is a humidity analyzer that uses two thermometers with the bulb of one thermometer kept moist (wet bulb) and the other bulb kept dry (dry bulb).
Recording psychrometer
Sling psychrometer
Psychrometric chart
Psychrometer
Wet-bulb hygrometer
_ is the ambient air temperature measured by a thermometer that is freely exposed to the air but shielded from other heating or cooling effects.
Dry bulb temperature
Wet bulb temperature
Sling temperature
Absolute humidity
Low temperature
A _ is the dependent variable that is to be controlled in a control system.
Controller
Process variable
control variable
primary element
Secondly element
A _ is a change in process conditions that changes the process variable (PV) and must be compensated for by a change in the control variable.
Lag
Gain
Load change
Reaction
Disturbance
A _ process is where the gain changes at different points on a process curve.
Linear
Nonlinear
Feedback
Feedforward
Dynamic
_ is the ability of a process to store material or energy.
Resistance
Potential
Inertia
Gain
Capacitance
_ is the period of time occurs between the time a change is made to a process and the time the first response to the change is detected.
Dead time
Lag
Gain
Feedback
Delay
A (n) _ loop is a control system that provides feedback to the controller on the state of the process variable.
Top control
Bottom-control
Closed
Open
Cascade control
_ control is method of changing the output of controller by an amount proportional to an error.
Proportional
Ratio
ON/OFF
Feedforward
Nonlinear
_ is the range of input values that corresponds to a full range of output from controller, stated as a percentage.
Integral control
Proportional band
Deadband
Offset
Sequential control
_ control is a method of changing the output of a controller by an amount proportional to an error and the duration of that error.
Proportional
Integral
Derivative
Ratio
Nonlinear
_ is a control strategy in which a primary controller that controls the ultimate measurements adjusts the setpoint of a secondary controller.
Fuzzy logic
Proportional band
Ratio control
Cascade control
Split-range
A (n) _ is a response where the amount of overshoot decays to one-fourth of the previous amplitude of the overshoot every whole cycle.
One-quarter decay ratio
Amplitude
Overshoot
Undershoot
Oscillation
Process with a lot of dead time must be tuned to _.
Respond quickly and maximize overshoot
Respond quickly and minimize overshoot
Respond slowly and maximize overshoot
Respond slowly and minimize overshoot
Avoid oscillations
The setpoint step change method consists of making small changes in the _ and observing the response.
Setpoint
Deadtime
Decay ratio
Gain
Process variable
_ is a method of tuning a controller by increasing the gain until the system cycles at the point of instability.
Controller gain tuning
Step response tuning
Dead-time compensation
Feedforward tuning
_ is a method of tuning a controller based on open loop response to a step input.
Setpoint step change input
Ziegler-Nichols open loop tuning
Ziegler-Nichols closed loop tuning
Dynamic response tuning
Feedforward tuning
A _ digital controller is general type of microprocessor-based controller with all required operating components enclosed in one housing.
Ziegler-Nichols
Stand-alone
Self-tuning
Function-block
Integrated
A distributed control system (DCS) has the individual functions distributed among a number of pieces of equipment that are connected by a _.
Control panel
High-speed digital communication network
Digital recorder
Null-balance network
Central server
An analog output controller is an electric controller that has _ as the output.
4 V to 2 V DC
4 V to 2 V AC
4 mA to 20 mA DC
4 mA to 20 mA AC
0 V to 10 V DC
_ is a configuration method that uses library of functions provided by the manufacturer.
Analog output
PC-based display
Structured text
Function block configuration
Block diagram
_ is a configuration method that consists of two vertical rails, the left one being the source and the right one being the end.
Input function block
Sequential function block
Structured text
Ladder logic
Block diagram
How many types of common control strategies do we have?
1
2
3
4
5
How many types of control elements do we have?
3
5
4
6
7
What types of effects do we have?
Seebeck
Peltier
Thomson
All of the above
None of the above
A tube to transport fluid substances is _.
Pipe
Vessel
Heat exchanger
Pump
Conduit
It is efficiently transfer heat.
Pipe
Vessel
Heat exchanger
Pump
Radiator
P&ID differs from PFD because _.
It is more specified
It is more difficult
There is more information
It is more detailed
All of the above
How many types of pressure do we have?
6
4
5
3
2
A (n) _ consists of a flexible metal which expands or contracts in response to a change in pressure.
Diaphragm
Pressure spring
Bellow
Double-ended piston
Pressure gauge
A (n) _ pressure transducer is a diaphragm pressure sensor with a metal diaphragm mounted between two stainless steel blocks.
Capacitance
Inductance
Reluctance
Resistance
Piezoelectric
A (n) _ pressure transducer is a diaphragm or bellow pressure sensor with electrical coils and a moveable ferrite core as the electrical element.
Capacitance
Inductance
Reluctance
Resistance
Strain gauge
Laser beams are intense, narrow light beams that can travel _ distances.
Long
Short
Medium
Limited
Infinite
What are the areas of application of PLC?
Food & beverage
Mining
Power
All of the above
None of the above
What does CPU stands for?
Central processing unit
Central primary unit
Control processing unit
Central programming unit
Core processing unit
Energy saving is _ of PLC.
Advantage
Disadvantage
Neutral aspect
Unnecessary feature
Optional feature
Fixed Circuit Operations is _ of PLC.
Advantage
Disadvantage
Neutral aspect
Unnecessary feature
Optional feature
PLC has _ sizes.
Two
Three
Four
Five
Six
The power supply provides _.
Isolation
Required voltage
Additional power supplies
All of the above
None of the above
The motor is permitted to run for _.
Two minutes
One minute
30 sec
15 sec
10 sec
Are “deodorants” and “soda” the area of applications of PLC?
Yes
No
Leading brands of PLC are _.
American
Japanese
European
All of the above
None of the above
The ___ is a federal agency under the U.S. Department of Labor that develops and enforces workplace safety and health regulations.
Environmental Protection Agency (EPA)
National Institute of Standards and Technology (NIST)
American National Standards Institute (ANSI)
Occupational Safety and Health Administration (OSHA)
International Society of Automation
___ control is the simplest and most common control strategy.
Derivative
Proportional
Integral
Deadband
ON/OFF
Dynamic characteristics are the characteristics of an element that describe the operation of the element at ________ conditions when the process is not changing.
Steady state
Setpoint
Controlled
Unsteady state
Certain
Process ___ is a system that combines measuring materials and controlling instruments into an arrangement capable of automatic action.
Response
Handling
Control
Variation
Change