Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Tutorial (15 MCQs) - Screen Film Radiography Image Quality

Total questions: 15

Worksheet time: 1hrs 15mins

Name
Class
Date
1.

Congestive heart failure causes increased tissue density due to fluid accumulation in the lungs and around the heart.  Which of the following exposure factor modification techniques need to be done?

a)

Increase exposure factor

b)

Decrease exposure factor

c)

No exposure change

2.

Which statement best defines film contrast?

a)

Different densities due to tissue thickness variation

b)

Different densities due to film emulsion response

3.

Which pair correctly matches contrast type with its cause?

a)

Subject contrast — tissue absorption differences

b)

Film contrast — patient thickness differences

c)

Film contrast — X-ray quality alone

d)

Subject contrast — emulsion response variations

4.

Which patient factor can alter tissue thickness in imaging?

a)

Tissue type and pathologic process

b)

Scanner brand and room lighting

c)

Technologist experience level

d)

Appointment time and patient age

5.

Which filters are stated to impact radiographic contrast?

a)

Inherent tube housing filters

b)

Compensating filters added externally

c)

Filtration in collimator light

6.

Which action would most likely lower image contrast when using intensifying screens?

a)

Switching from 400 speed to 200 speed

b)

Increasing screen speed progressively

c)

Maintaining 400 speed across exposures

7.

Which of the following is NOT listed as a synonym for resolution?

a)

Clarity

b)

Contrast

c)

Sharpness

d)

Recorded detail

8.

What patient-related aspect is listed as affecting image resolution?

a)

Exposure time exclusively decides

b)

Detector brand determines it

c)

Only technician skill matters

d)

Patient factor is included

9.

Which factor can degrade resolution due to subject or equipment movement?

a)

Motion during exposure

b)

Smaller focal spot only

c)

Higher SID alone

10.

Which combination best represents operator-controlled geometry affecting resolution?

a)

Modifying detector thickness

b)

Altering pathology severity

c)

Adjusting SID and OID

11.

What does SID stand for in radiographic imaging?

a)

Subject to image definition

b)

Screen to input detector

c)

Source to incident dose

d)

Source to image distance

12.

What does OID refer to in radiography?

a)

Optical input diameter

b)

Output intensity deviation

c)

Operator imaging directive

d)

Object to image distance

13.

What is a common standard SID used during routine patient X-rays?

a)

200 cm frequently

b)

50 cm commonly

c)

100 cm typically

14.

When a structure is not parallel with the image receptor, which resolution effect can occur?

a)

Improved detail due to alignment

b)

No change if exposure factors are correct

c)

Distortion leading to reduced resolution

d)

Magnification without shape change

15.

What is the typical effect of increasing focal spot size?

a)

Decreases sharpness

b)

Increases sharpness

c)

No change in sharpness