If the primary coil voltage ratings of the transformers match the _____________________, then connect _____________.

Transformer Connection Flashcard

Flashcard
•
Other
•
Professional Development
•
Hard
Quizizz Content
FREE Resource
Student preview

16 questions
Show all answers
1.
FLASHCARD QUESTION
Front
Back
phase-to-ground voltage of the system; Wye.
2.
FLASHCARD QUESTION
Front
During a practical session, Elijah was examining a transformer that had only one number for a primary coil voltage rating. He wondered what this indicated about its usage.
Back
it should be used for Delta connections only.
3.
FLASHCARD QUESTION
Front
Ava is working on a project that involves setting up electrical systems. She needs to determine which of these service voltages on the work order require “Alley-Cat/Bad-Dog”? 120/208, 240, 120/240, 240/480
Back
120/208
4.
FLASHCARD QUESTION
Front
What is the reason for connecting the secondary windings in parallel?
Back
To use the full kVA rating of the transformers.
5.
FLASHCARD QUESTION
Front
Which of these combinations best represents the connection for paralleling the windings? Options: Connect “A” and “B” together to a bushing, then “C” and “D” together to another bushing.; Connect “A” and “C” together to a bushing, and then “B” and “D” together to another bushing.; Connect “A” and “D” together to a bushing, then “B” and “C” together to another bushing.; Connect “A” and “C” together to a bushing, and leave “B” and “D” in place.
Back
Connect “A” and “C” together to a bushing, and then “B” and “D” together to another bushing.
6.
FLASHCARD QUESTION
Front
Harper is working on a project to supply three-phase power from an underground system. Which of these statements about using underground transformers for three-phase service is true?
- When supplying three-phase power from underground systems, the transformers used are always single units.
- The “Power” pad-mount used in an open bank configuration must have the grounding strap removed from the X2.
- Only three-phase pad-mounts may be used.
- The banking connections for three-phase units must be done externally.
Back
The “Power” pad-mount used in an open bank configuration must have the grounding strap removed from the X2.
7.
FLASHCARD QUESTION
Front
Which of these statements regarding Non-Standard Connections is true? Options: You can get 120/208 from single-phase Delta. It’s possible to get two 120/208 3-phase services from one Delta-Delta bank. To complete a three-phase connection, you must ground at the X2 only. A Delta or Wye can be grounded one time at any coil terminal and still operate properly.
Back
A Delta or Wye can be grounded one time at any coil terminal and still operate properly.
Create a free account and access millions of resources
Similar Resources on Quizizz
15 questions
Friday 11/21

Flashcard
•
KG
15 questions
Suspension and Steering Components

Flashcard
•
University
6 questions
Understanding Transformer Connections and Three-Phase Units

Flashcard
•
Professional Development
12 questions
Understanding Transformer Concepts

Flashcard
•
Professional Development
10 questions
GenAI

Flashcard
•
Professional Development
9 questions
Solar Installation Master Class

Flashcard
•
Professional Development
15 questions
Block IV Study Guide

Flashcard
•
Professional Development
9 questions
STAGES OF SLEEP

Flashcard
•
University
Popular Resources on Quizizz
10 questions
Chains by Laurie Halse Anderson Chapters 1-3 Quiz

Quiz
•
6th Grade
20 questions
math review

Quiz
•
4th Grade
15 questions
Character Analysis

Quiz
•
4th Grade
12 questions
Multiplying Fractions

Quiz
•
6th Grade
30 questions
Biology Regents Review #1

Quiz
•
9th Grade
20 questions
Reading Comprehension

Quiz
•
5th Grade
20 questions
Types of Credit

Quiz
•
9th - 12th Grade
50 questions
Biology Regents Review: Structure & Function

Quiz
•
9th - 12th Grade