Ventilation Requirements for Gas Appliances
Flashcard
•
Other
•
Professional Development
•
Practice Problem
•
Hard
Eugene Schutte
FREE Resource
Student preview

15 questions
Show all answers
1.
FLASHCARD QUESTION
Front
Minimum free area of permanent ventilation for a gas cooker and open flued boiler in a kitchen above 10 m³ with a door to outside.
Back
32.5 cm²
2.
FLASHCARD QUESTION
Front
Additional vent free area to remedy spillage from an open flued appliance due to a depressurising extract fan.
Back
An extra 50 cm²
3.
FLASHCARD QUESTION
Front
Factors that may reduce allowances for 'adventitious ventilation' for a gas fire.
Back
Curtains, cat flaps, draught proofing, house location
4.
FLASHCARD QUESTION
Front
Minimum ventilation requirement for an open flued, decorative fuel effect appliance with a maximum rated input of 10 kW (net).
Back
50 cm²
5.
FLASHCARD QUESTION
Front
Placement of permanent ventilation for two open flued, decorative fuel effect appliances in a through room.
Back
Have 50% of the ventilation provision sited equally at either end of the room.
6.
FLASHCARD QUESTION
Front
Total rated input for a gas cooker mentioned in the document.
Back
17.5 kW (net)
7.
FLASHCARD QUESTION
Front
Maximum rated input for an open flued boiler mentioned in the document.
Back
13.5 kW (net)