Search Header Logo
Unit 317 Session 4b Underfloor heating underpinning knowledge

Unit 317 Session 4b Underfloor heating underpinning knowledge

Assessment

Presentation

Other

Vocational training

Easy

Created by

Plumbers Cymoedd

Used 3+ times

FREE Resource

2 Slides • 33 Questions

1

​Underfloor heating

media

2

​Open the document by clicking on the the link below and an answer the questions that follow:

Underfloor chapter.pdf

3

Multiple Choice

Which of the following is a benefit of underfloor heating systems?

1

High temperature operation

2

Visible heat sources

3

Eliminates cold spots

4

Requires radiators

4

Multiple Choice

What is the typical temperature range for underfloor heating in screeded floors?

1

30–35°C

2

40–45°C

3

50–55°C

4

60–65°C

5

Multiple Choice

What is the main method of heat emission in underfloor heating systems?

1

Convection only

2

Radiation only

3

Conduction and radiation

4

Convection and conduction

6

Multiple Choice

What is the recommended maximum TOG rating for floor coverings used with underfloor heating?

1

1.0

2

1.5

3

2.0

4

2.5

7

Multiple Choice

Which of the following is NOT a common fuel type used in underfloor heating systems?

1

Gas

2

Oil

3

Coal

4

Biomass

8

Multiple Choice

What is the purpose of using a thermostatic blending valve in an underfloor heating system?

1

To increase the water pressure

2

To blend the flow water with return water

3

To reduce the noise of the system

4

To filter impurities from the water

9

Multiple Choice

Why is zoning with 2-port motorised zone valves beneficial in heating systems?

1

It reduces the cost of installation

2

It allows for independent time control of heat emitters

3

It increases the water temperature

4

It simplifies the plumbing layout

10

Multiple Choice

What is one advantage of underfloor heating systems?

1

They are very noisy compared to other systems.

2

They have a higher possibility of leaks.

3

They allow better positioning of furniture and interior design.

4

They require radiators to drain and remove.

11

Multiple Choice

Which of the following is a disadvantage of underfloor heating systems?

1

They are environmentally friendly.

2

They have a lower possibility of leaks.

3

They can be expensive to install.

4

They provide better heat distribution.

12

Multiple Choice

How is each underfloor heating circuit controlled?

1

By a central thermostat for the entire system.

2

By a room thermostat that activates a motorised head.

3

By manual adjustment of the pipes.

4

By a single thermostat for all rooms.

13

Multiple Choice

What is the primary function of a manifold in an underfloor heating system?

1

To increase the temperature of the water

2

To distribute heat energy evenly

3

To cool down the water

4

To add pressure to the system

14

Multiple Choice

What component is used to mix the flow and return water to the required temperature in underfloor heating circuits?

1

Circulating pump

2

Isolation valve

3

Thermostatic mixing valve

4

Pressure gauge

15

Multiple Choice

Where is the circulating pump located in an underfloor heating system?

1

Between the heat source and the manifold

2

Between the thermostatic mixing valve and the flow manifold

3

At the end of the heating circuit

4

Next to the pressure gauge

16

Multiple Choice

What is the main purpose of the series pattern in underfloor heating systems?

1

To ensure an even temperature across the floor

2

To create a decorative pattern

3

To reduce installation costs

4

To increase water flow speed

17

Multiple Choice

Which pattern is also known as the bifilar pattern?

1

The snail pattern

2

The series pattern

3

The zigzag pattern

4

The spiral pattern

18

Multiple Choice

What is a key consideration when positioning components in underfloor central heating systems?

1

Ensuring the efficiency of the system

2

Reducing the number of components

3

Increasing the size of the components

4

Decreasing the water temperature

19

Multiple Choice

Why is the positioning of the manifold important in underfloor heating systems?

1

To balance the length of each circuit

2

To increase the water temperature

3

To reduce the number of circuits

4

To enhance the aesthetic appeal

20

Multiple Choice

What is a potential problem that may occur where the manifold is located in a plumbing system?

1

Increased water pressure

2

Potential 'hot spot' due to pipework congestion

3

Reduced water flow

4

Pipe corrosion

21

Multiple Choice

What should be considered when setting out the pattern for pipework arrangements?

1

The color of the pipes

2

The orientation and shape of the room

3

The type of water used

4

The height of the ceiling

22

Multiple Choice

What is the recommended design flow temperature for underfloor heating on a solid floor?

1

30°C

2

40°C

3

50°C

4

60°C

23

Multiple Choice

What is the maximum circuit length for a 15 mm pipe in underfloor heating?

1

80 m

2

90 m

3

100 m

4

110 m

24

Multiple Choice

What is the maximum heat output for a suspended timber floor system?

1

50 W/m²

2

70 W/m²

3

90 W/m²

4

100 W/m²

25

Multiple Choice

What is the recommended design flow temperature for a suspended timber floor system?

1

50°C

2

55°C

3

60°C

4

65°C

26

Multiple Choice

What is the maximum circuit length for a suspended timber floor system using a 15 mm pipe?

1

60 m

2

70 m

3

80 m

4

90 m

27

Multiple Choice

How much coverage per circuit is provided using a double spreader plate at 225 mm centres?

1

15 m²

2

17 m²

3

19 m²

4

21 m²

28

Multiple Choice

Diagram of solid floor underfloor heating installation showing components like tiled floor covering, edge insulation, and underfloor heating pipes.

1

Wooden floor covering

2

Carpet insulation

3

Radiator heating system

4

Tiled floor covering

29

Multiple Choice

What is the purpose of double heat spreader plates in underfloor heating installations?

1

To provide structural support

2

To distribute heat evenly

3

To insulate the floor

4

To reduce noise

30

Multiple Choice

In a suspended floor underfloor heating installation, what is placed directly above the underfloor heating pipes?

1

Finished floor surface

2

Floating floor panels

3

Tongued and grooved floor boards

4

Wall

31

Multiple Choice

What component is used in both suspended and floating floor underfloor heating installations to cover the heating pipes?

1

Timber joists

2

Insulation

3

Double heat spreader plates

4

Wall

32

Multiple Choice

What is the recommended design flow temperature for a floating floor heating system?

1

50°C

2

60°C

3

70°C

4

80°C

33

Multiple Choice

What is the maximum heat output for a floating floor heating system?

1

50 W/m²

2

60 W/m²

3

70 W/m²

4

80 W/m²

34

Multiple Choice

What is the maximum circuit length for a 15 mm pipe in a floating floor heating system?

1

60 m

2

70 m

3

80 m

4

90 m

35

Multiple Choice

What should be done before commissioning an underfloor heating system?

1

Install the floor panels

2

Flush the heating circuits with water

3

Connect the hydraulic test pump

4

Set the correct temperature at the manifold

​Underfloor heating

media

Show answer

Auto Play

Slide 1 / 35

SLIDE