Hot Water 1

Hot Water 1

University

15 Qs

quiz-placeholder

Similar activities

QUIZ SECTION 1 DAY 5

QUIZ SECTION 1 DAY 5

7th Grade - University

20 Qs

iNTRODUCTION TO OS

iNTRODUCTION TO OS

University

10 Qs

BCSI AWARENESS

BCSI AWARENESS

KG - Professional Development

15 Qs

Week 8: Feelings and emotions

Week 8: Feelings and emotions

University

17 Qs

QUIZ 1

QUIZ 1

University

10 Qs

AMT 221 Semifinal Long Quiz

AMT 221 Semifinal Long Quiz

University

15 Qs

BAC1054 Process Costing

BAC1054 Process Costing

University

15 Qs

QUIZ - PERALATAN KHUSUS PATISERI

QUIZ - PERALATAN KHUSUS PATISERI

University

10 Qs

Hot Water 1

Hot Water 1

Assessment

Quiz

Other

University

Medium

Created by

Steve Endicott

Used 758+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of fitting must not be used on hot water pipework?

Capillary fitting with a lead/tin solder.
Proprietary push-fit plastic fitting.
Non-manipulative compression fitting.
Proprietary push-fit copper fitting.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which British Standard details the installation requirements for hot water systems?

BS 5449.
BS 6700.
BS EN 12056.
BS EN 12976.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What is the device shown

Measuring water pressures.
Measuring water flow rates
Sizing hot water cylinders
Determining the pH of water

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

What type of tool is shown

Adjustable spanner
Immersion heater spanner
Stillson wrench
Water pump pliers

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image

The additional pipework circuit fitted to a hot water system to overcome dead-legs in the system is known as a

primary circulation system
Trace heating 
secondary circulation system
inverted loop system.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In which one of the following locations is it a requirement to insulate hot water system pipework?

Surface mounted in a lounge.
‘Notched’ into timber first floor joists.
In a loft space.
Surface mounted in a bathroom

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the required soundness test pressure for hot water pipework which will normally be subject to a static head of 6 metres (assuming that 1 metre head of water is about 0.1 bar pressure)?

1.0 bar
0.6 bar
0.09 bar
0.9 bar.

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?