Hot Water 1

Hot Water 1

University

15 Qs

quiz-placeholder

Similar activities

Outboard Engines

Outboard Engines

University

10 Qs

AK B4 PENGANGKUTAN (SET 6@ LITAR PNEUMATIK)

AK B4 PENGANGKUTAN (SET 6@ LITAR PNEUMATIK)

University

20 Qs

Sharing session desember

Sharing session desember

University

10 Qs

Hot Water 2

Hot Water 2

University

15 Qs

Hot Water 3

Hot Water 3

University

15 Qs

CW - Special Components Quiz PP7

CW - Special Components Quiz PP7

University

15 Qs

Auto Tech Basics 1

Auto Tech Basics 1

8th Grade - University

20 Qs

Rec-101 Water Systems Level 1 Module 1

Rec-101 Water Systems Level 1 Module 1

University

14 Qs

Hot Water 1

Hot Water 1

Assessment

Quiz

Other

University

Medium

Created by

Steve Endicott

Used 747+ times

FREE Resource

15 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which type of fitting must not be used on hot water pipework?
Capillary fitting with a lead/tin solder.
Proprietary push-fit plastic fitting.
Non-manipulative compression fitting.
Proprietary push-fit copper fitting.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which British Standard details the installation requirements for hot water systems?
BS 5449.
BS 6700.
BS EN 12056.
BS EN 12976.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
What is the device shown
Measuring water pressures.
Measuring water flow rates
Sizing hot water cylinders
Determining the pH of water

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
What type of tool is shown
Adjustable spanner
Immersion heater spanner
Stillson wrench
Water pump pliers

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Media Image
The additional pipework circuit fitted to a hot water system to overcome dead-legs in the system is known as a
primary circulation system
Trace heating 
secondary circulation system
inverted loop system.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In which one of the following locations is it a requirement to insulate hot water system pipework?
Surface mounted in a lounge.
‘Notched’ into timber first floor joists.
In a loft space.
Surface mounted in a bathroom

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the required soundness test pressure for hot water pipework which will normally be subject to a static head of 6 metres (assuming that 1 metre head of water is about 0.1 bar pressure)?
1.0 bar
0.6 bar
0.09 bar
0.9 bar.

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?