Unit 04 CBT

Unit 04 CBT

University

55 Qs

quiz-placeholder

Similar activities

MIDTERM EXAM

MIDTERM EXAM

University

50 Qs

TRY OUT P3K Penjas 21

TRY OUT P3K Penjas 21

University

56 Qs

Industrial Engineering

Industrial Engineering

University

60 Qs

Philippine Electrical Code (Subject 6) - Nth

Philippine Electrical Code (Subject 6) - Nth

University

50 Qs

Политическая наука: Вопросы и Ответы

Политическая наука: Вопросы и Ответы

University

56 Qs

FINAL EXAM: LIVING IN THE IT ERA

FINAL EXAM: LIVING IN THE IT ERA

University

50 Qs

LATIHAN UP KODE x & Z

LATIHAN UP KODE x & Z

University

60 Qs

TOPIK 1

TOPIK 1

University

50 Qs

Unit 04 CBT

Unit 04 CBT

Assessment

Quiz

Other

University

Medium

Used 5+ times

FREE Resource

55 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a connection method of operating a reed switch in an alarm circuit?

High temperature smoke surrounding the switch

Providing a magnet close to the switch

Provides heating near the switch

Providing a coil point

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of the radioactive source in a smoke Alarm?

To repel smoke particles

To attract smoke particles

To provide a high resistance within the detector

To provide a constant current flow within the detector

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the supply arrangement for a security system?

Rectified ac supply

Primary cell battery

Rectified ac supply with back up battery

High voltage supply with back up battery

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does an end of line resistor connected in series with a normally closed call point do?

Helps to prolong battery life

Prevents short circuit currents

Allows the control panel to detect a short circuit on the wiring

Prevents the control panel from detecting an open circuit in the wiring

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Why does a security panel have “zones”?

To provide access control

To permit admissible entry

To monitor areas at the same time

To be able to monitor areas individually

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What modification is required to the circuit below so that an open circuit wiring fault can be detected by the alarm panel?

Add a resistor in series with the existing resistor

Add a resistor in parallel with the contact

Change the contact to normally open

Change the value of the resistor

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which connection arrangement for the detectors of a fully addressable fire alarm system is correct?

The same detector type must be used in each zone

Any detector can be connected on any zone

The detector wiring will determine the zones

No detector zoning is required for the installation

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?