#6 EPA 608 Type III

#6 EPA 608 Type III

11th Grade - Professional Development

25 Qs

quiz-placeholder

Similar activities

Automotive Air Conditioning Principals

Automotive Air Conditioning Principals

12th Grade

20 Qs

HAC-101 Chap 59 HVAC System Servicing (Auto) Test B

HAC-101 Chap 59 HVAC System Servicing (Auto) Test B

University

20 Qs

AIR CONDITIONER SYSTEM PRE/POST TETS

AIR CONDITIONER SYSTEM PRE/POST TETS

Professional Development

20 Qs

Pre Test AC System 1

Pre Test AC System 1

University

25 Qs

Seleksi Pelatihan Service AC Rumah Tangga

Seleksi Pelatihan Service AC Rumah Tangga

Professional Development

20 Qs

EPA Type 3

EPA Type 3

9th - 12th Grade

20 Qs

HVAC Quiz #2

HVAC Quiz #2

University

20 Qs

core quiz 2 August 22 - August 28

core quiz 2 August 22 - August 28

Professional Development

21 Qs

#6 EPA 608 Type III

#6 EPA 608 Type III

Assessment

Quiz

Other

11th Grade - Professional Development

Medium

Created by

Mike Conway

Used 316+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Identify the pressure corresponding to 32°F for R-123.

23 inches of Hg vacuum

20 inches of Hg vacuum

17 inches of Hg vacuum

11 inches of Hg vacuum

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is a typical advantage of a water cooled recovery unit?

Higher pressure at the recovery compressor's discharge.

Higher pressure in the recovery tank.

Faster recovery of large quantities of refrigerant.

Greater percentage of refrigerant recovered.

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

1. Which of the following statements about R-1233zd is FALSE?

It is a SNAP approved replacement for low-pressure centrifugal compressor systems.

It is being considered for applications where R-123 might have been used.

It is suitable for air conditioning applications where cooling water is used (large chiller applications).

It is mildly flammable.

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following methods can be used to pressurize an R-1233zd system for the purpose of opening the system for a non-major repair?

Adding nitrogen to the system.

Warming the liquid refrigerant in the system.

Adding compressed air to the system's condenser.

Adding carbon dioxide to the system's condenser and evaporator

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following statements is true of recycling and recovery equipment?

It must be tested by an AHRI-approved third party.

It must be equipped with low-loss ball valves and flare fittings.

It must be able to handle more than one refrigerant.

It must be labeled as certified to meet EPA's requirements.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Starting in 2019, what is the leak rate threshold for industrial process refrigeration equipment with a full charge of 50 or more pounds of an HCFC refrigerant?

5%

10%

20%

30%

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Where is the rupture disc located on a centrifugal chiller?

Condenser

Evaporator

Liquid line

Economizer

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?