Reactive power control

Reactive power control

University

20 Qs

quiz-placeholder

Similar activities

Basics of Electrical Engg 1

Basics of Electrical Engg 1

University

25 Qs

Physics_1_27_Chapter

Physics_1_27_Chapter

University

20 Qs

Friends - The One with Rachel's Other Sister

Friends - The One with Rachel's Other Sister

10th Grade - University

18 Qs

GUIDANCE

GUIDANCE

University

20 Qs

MINECRAFT BRUH

MINECRAFT BRUH

KG - Professional Development

15 Qs

LESSON 8

LESSON 8

University

21 Qs

Evaluación mes 2

Evaluación mes 2

University - Professional Development

20 Qs

electrical

electrical

University

20 Qs

Reactive power control

Reactive power control

Assessment

Quiz

Special Education

University

Hard

Created by

Mr. Chavan

Used 2+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

an overhead line with the series compensation is protected using

Impedance relay

Reactance relay

Mho relay

None of anyone

2.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Shunt compensation in an EHV is resorted to

Improve the stability

Reduce the fault level

Improve the voltage profile

As a substitute for synchronous phase modifier

3.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

for stability and economic reasons, we operate the transmission line with power angle in the range

10 degree to 25 degree

30 degree to 45 degree

60 degree to 75 degree

65 degree to 80 degree

4.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

Series compensation on EHV lines is resorted to

Improve the stability

Reduce the fault level

Improve the voltage profile

As a substitute for synchronous phase modifier

5.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

The voltage of a particular bus can be controlled by controlling the

Phase angle

Reactive power of the bus

Active power of the bus

Phase angle and reactive power

6.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

With the help of a reactive compensator it is possible to have

Constant voltage operation only

Unity pf operation only

Both constant voltage and unity pf

Either constant voltage or unity pf

7.

MULTIPLE CHOICE QUESTION

1 min • 1 pt

For a long uncompensated line the limit to the line loading is governed by

Thermal limit

Voltage limit

Stability limit

Corona loss

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?