Monthly JATC quiz 12/2023

Monthly JATC quiz 12/2023

Professional Development

10 Qs

quiz-placeholder

Similar activities

Car Naming Systems

Car Naming Systems

3rd Grade - Professional Development

15 Qs

Văn hóa ứng xử trên mạng xã hội

Văn hóa ứng xử trên mạng xã hội

Professional Development

15 Qs

Customer Service: Soft Skills

Customer Service: Soft Skills

Professional Development

10 Qs

Medical 🏥

Medical 🏥

KG - Professional Development

10 Qs

Tynker Tynker

Tynker Tynker

3rd Grade - Professional Development

9 Qs

Meeting 1 Exit Ticket

Meeting 1 Exit Ticket

Professional Development

12 Qs

Tech Alumni 8

Tech Alumni 8

Professional Development

15 Qs

Organizational Etiquette

Organizational Etiquette

Professional Development

10 Qs

Monthly JATC quiz 12/2023

Monthly JATC quiz 12/2023

Assessment

Quiz

Life Skills

Professional Development

Practice Problem

Hard

Created by

Robert Starcher

Used 12+ times

FREE Resource

AI

Enhance your content in a minute

Add similar questions
Adjust reading levels
Convert to real-world scenario
Translate activity
More...

10 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

15 mins • 10 pts

Where a water flow test is used for the purposes of system design, the test shall be conducted no less than ____ months prior to working plan submittal unless otherwise approved by the authority having jurisdiction.

6

12

18

1

2.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

What NFPA 13 2019 standard reference number states that draft stops shall be at least 18" deep?

(Example: 32.7.9)

3.

MULTIPLE CHOICE QUESTION

15 mins • 10 pts

The horizontal distance between pilot line detectors installed outdoors on a given level shall be permitted to be increased to ____________ feet when all the following conditions are met:

10

8

25

20

4.

MULTIPLE CHOICE QUESTION

15 mins • 10 pts

Except as provided by 5.1.3.2 or 5.1.3.3, no pipe smaller than _____ inches in diameter shall be installed as a private service main.

6

4

10

8

5.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

A listed strainer shall be provided on the supply side of sprinklers with nominal K-factors of less than

K- ____

6.

FILL IN THE BLANK QUESTION

15 mins • 10 pts

NFPA ___ is the Standard on Water Mist Fire Protection Systems

7.

MULTIPLE CHOICE QUESTION

15 mins • 10 pts

Sprinklers in concealed spaces having no access for storage or other use shall be installed in accordance with the requirements for ________ hazard occupancy.

ordinary

light

extra

special

 

Create a free account and access millions of resources

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

By signing up, you agree to our Terms of Service & Privacy Policy

Already have an account?