8202L3CHPPT9Q1

8202L3CHPPT9Q1

12th Grade

18 Qs

quiz-placeholder

Similar activities

Supreme Court Cases - Criminal Investigations

Supreme Court Cases - Criminal Investigations

11th - 12th Grade

15 Qs

EOPA - ECONOMICS

EOPA - ECONOMICS

10th - 12th Grade

15 Qs

Şiir Bilgisi

Şiir Bilgisi

9th - 12th Grade

16 Qs

Concussion Quizizz #2--Intro

Concussion Quizizz #2--Intro

10th - 12th Grade

20 Qs

Stage directions and Fixed points

Stage directions and Fixed points

9th - 12th Grade

20 Qs

Beef Meet Cuts

Beef Meet Cuts

9th - 12th Grade

21 Qs

Accidentals & Key Signatures II

Accidentals & Key Signatures II

KG - University

22 Qs

(Round 2) Major Scales, Intervals, Whole/Half Steps

(Round 2) Major Scales, Intervals, Whole/Half Steps

7th Grade - University

20 Qs

8202L3CHPPT9Q1

8202L3CHPPT9Q1

Assessment

Quiz

Other

12th Grade

Hard

Created by

William Heron

FREE Resource

18 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

When will Part P be satisfied?

A) If the work is carried out by a registered competent person

B) If all fundamental principles for achieving electrical safety are achieved

C) Both A and B

D) None of the above

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What do components do in an over-current situation?

A) Protect and isolate individual circuits

B) Increase the current flow

C) Both A and B

D) None of the above

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What must an engineer ensure before carrying out pre-installation examinations to the fused spur?

A) Disconnect the main power supply

B) Ensure safe isolation of the proposed circuit

C) Both A and B

D) None of the above

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the purpose of an RCD in a consumer unit?

A) To control total isolation of the dwelling

B) To provide protection to the user

C) Both A and B

D) None of the above

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Under what circumstances is electrical work on domestic premises considered non-notifiable according to Part P regulations?

A) If it is carried out by a registered competent person

B) If it is minor work

C) Both A and B

D) None of the above

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the first step in safe isolation?

A) Identify the source for the supply

B) Prove that the circuit is 'live'

C) Test the voltage indicator on a 'known source'

D) Switch off the identified MCB

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What do consumer units house for radial and ring final circuits?

A) MCBs

B) RCDs

C) Both A and B

D) None of the above

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?