PM WORKSHOP 2024 - QUIZ

PM WORKSHOP 2024 - QUIZ

Professional Development

25 Qs

quiz-placeholder

Similar activities

Dermatophytosis and Dermatomycosis

Dermatophytosis and Dermatomycosis

University - Professional Development

20 Qs

Form Fill Seal

Form Fill Seal

Professional Development

22 Qs

Leadership/ Delegation

Leadership/ Delegation

University - Professional Development

20 Qs

Traditional dishes

Traditional dishes

10th Grade - Professional Development

20 Qs

Music Modes and Music Theory

Music Modes and Music Theory

Professional Development

20 Qs

Domestic Heating Compliance Quiz

Domestic Heating Compliance Quiz

Professional Development

20 Qs

ผลิตภัณฑ์ใหม่ 2023

ผลิตภัณฑ์ใหม่ 2023

Professional Development

30 Qs

142 CBT Review

142 CBT Review

Professional Development

30 Qs

PM WORKSHOP 2024 - QUIZ

PM WORKSHOP 2024 - QUIZ

Assessment

Quiz

Specialty

Professional Development

Hard

Created by

Academy LOVATO Electric

Used 4+ times

FREE Resource

25 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The operating voltage range of the GLCM with rated power supply 230V is:

220...240V

198...264V

166...332V

208...277V

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The input "OFF" in the GLCM motorized changeover:

Forces the device to position 0

Is only enabled with the handle inserted

Force the device to a programmable position

Has less priority than any command sent over RS485

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In order to enable the contactor logic in the GLCM motorized changeover

Jumper the terminals I-II

Jumper the terminals 0-COM

Remove the inputs terminal block

Insert the handle only in AUTOMATIC mode

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The expansion slot integrated in the GLCM motorized changeover can fit:

RS485 module only

Output expansion modules only

Output expansion modules or RS485 module

Ethernet module

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which is the max motor size that can be controlled by an electronic motor starter on the market (Lovato or competitors)?

9A

10A

7A

2,4A

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Select the correct list of selling points of ME electronic motor starters compared to a contactor

Compact dimensions, longer life, more functions in one device, lower price

Easy wiring, wider motor current range, more functions in one device, lower price

Starting with ramp, better EMC performance, compact dimensions, less noise

Compact dimensions, longer life, more functions in one device, fast switching

7.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which is/are the advantage of the inside-delta connection on soft starters?

Easier wiring

Possibility to control a big motor with a soft starter with lower current

Easy replacement of star-delta starter

No need of bypass