1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The operating voltage range of the GLCM with rated power supply 230V is:

220...240V

198...264V

166...332V

208...277V

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The input "OFF" in the GLCM motorized changeover:

Forces the device to position 0

Is only enabled with the handle inserted

Force the device to a programmable position

Has less priority than any command sent over RS485

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

In order to enable the contactor logic in the GLCM motorized changeover

Jumper the terminals I-II

Jumper the terminals 0-COM

Remove the inputs terminal block

Insert the handle only in AUTOMATIC mode

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The expansion slot integrated in the GLCM motorized changeover can fit:

RS485 module only

Output expansion modules only

Output expansion modules or RS485 module

Ethernet module

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which is the max motor size that can be controlled by an electronic motor starter on the market (Lovato or competitors)?

9A

10A

7A

2,4A

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Select the correct list of selling points of ME electronic motor starters compared to a contactor

Compact dimensions, longer life, more functions in one device, lower price

Easy wiring, wider motor current range, more functions in one device, lower price

Starting with ramp, better EMC performance, compact dimensions, less noise

Compact dimensions, longer life, more functions in one device, fast switching

7.

MULTIPLE SELECT QUESTION

45 sec • 1 pt

Which is/are the advantage of the inside-delta connection on soft starters?

Easier wiring

Possibility to control a big motor with a soft starter with lower current

Easy replacement of star-delta starter

No need of bypass

Access all questions and much more by creating a free account

Create resources

Host any resource

Get auto-graded reports

Google

Continue with Google

Email

Continue with Email

Classlink

Continue with Classlink

Clever

Continue with Clever

or continue with

Microsoft

Microsoft

Apple

Apple

Others

Others

Already have an account?