Earth Faults and Protection Quiz

Earth Faults and Protection Quiz

12th Grade

20 Qs

quiz-placeholder

Similar activities

Residential Service & Overcurrent Protection

Residential Service & Overcurrent Protection

11th - 12th Grade

20 Qs

Electrical Grid 2 Ch. 1

Electrical Grid 2 Ch. 1

12th Grade - University

20 Qs

Electric Shock and Earthing Quiz

Electric Shock and Earthing Quiz

9th Grade - University

20 Qs

Electrical Quiz 2/10/23

Electrical Quiz 2/10/23

9th - 12th Grade

20 Qs

Vehicle

Vehicle

7th Grade - Professional Development

20 Qs

Building Utilities 2: Review

Building Utilities 2: Review

9th Grade - University

20 Qs

BEEE Pre-test Assessment

BEEE Pre-test Assessment

University

20 Qs

Earthing Arrangements Quiz

Earthing Arrangements Quiz

12th Grade - University

23 Qs

Earth Faults and Protection Quiz

Earth Faults and Protection Quiz

Assessment

Quiz

Other

12th Grade

Medium

Created by

M D

Used 1+ times

FREE Resource

20 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does the term 'earth fault loop path' describe?

The resistance of the live conductor

The altered path of current during an earth fault

The voltage drop in a circuit

The circuit's insulation properties

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the formula for calculating earth fault loop impedance (Zs)?

Zs = R1 + R2

Zs = Ze + R1 + R2

Zs = R1 × R2

Zs = Ze − R1 − R2

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which components are part of the earth fault loop impedance?

Circuit breaker resistance

Line conductor, protective conductor, and supply transformer resistance

Neutral conductor and live conductor resistance

Insulation resistance

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the standard disconnection time for distribution circuits in a TN system according to BS 7671?

1 second

5 seconds

10 seconds

15 seconds

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the disconnection time for final circuits exceeding 32A in a TT system?

0.5 seconds

1 second

2 seconds

5 seconds

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the significance of Zs being less than 80% of the maximum permitted value?

To allow for temperature rise in conductors under fault conditions

To ensure proper voltage regulation

To reduce power consumption

To avoid overloading the transformer

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What does functional earthing primarily assist with?

Protective purposes

Proper functioning of equipment

Voltage regulation in the circuit

Reduction of overcurrent

Create a free account and access millions of resources

Create resources
Host any resource
Get auto-graded reports
or continue with
Microsoft
Apple
Others
By signing up, you agree to our Terms of Service & Privacy Policy
Already have an account?