wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Electrical and Electronic Measurements

Total questions: 20

Worksheet time: 11mins

Name
Class
Date
1.

A measuring system consists of

a)

Sensors

b)

Variable conversion elements

c)

Signal processing elements

d)

All of these

2.

Which of the following quantities cannot be measured using Multi-Meter:

a)

Resistance

b)

Voltage

c)

Current

d)

Power Factor

3.

In a Circuit, Ammeter should be always connected in ____ arrangement

a)

Series

b)

Parallel

c)

Either in Series or in Parallel

d)

Can be connected in booth

4.

Wattmeter is used to measure which of the following:

a)

Both AC Power and DC Power

b)

DC Power only

c)

AC Power only

5.

An instrument in which the value of ethnical quantity to be measured can be determined from the deflection of the instrument when it has been precalibrated by comparison with an absolute instrument

a)

Absolute instrument

b)

Secondary instrument

c)

Recording instrument

d)

Integrating instrument

6.

A pointer of an instrument once deflected returns to zero position, when the current is removed due to

a)

Action of gravity

b)

Mass of the pointer

c)

Controlling Torque

d)

Damping Torques

7.

An ammeter

a)

Is inserted in series in a circuit and current to be measured flows through it

b)

Is inserted in series in a circuit and part of the current to be measured flows through it

c)

Is connected in parallel in a circuit and current to be measured flows through it

d)

Is connected in parallel in a circuit and only part of the current to the measured flows through it.

8.

_________ and ________________ are the methods of measurements

(a)  

9.

Which of the following is not an integrating instrument?

a)

Ampere-hour meter

b)

Watt-hour meter

c)

Voltmeter

d)

All of the above

10.

The deflecting torque in an instrument may be produced

a)

Magnetically

b)

Electrostatically

c)

Thermally

d)

Any of the above

11.

The advantages of moving coil permanent magnet type instrument are

a)

Low power consumption

b)

No hysteresis loss

c)

Efficient eddy current damping

d)

All of the above

12.

Induction type single phase energy meters measure electric energy in

a)

kW

b)

Wh

c)

kWh

d)

VAR

13.

A moving iron instrument can be used for

a)

DC only

b)

AC only

c)

Both AC and DC

d)

None of the above

14.

Systematic errors are

a)

Instrumental errors

b)

Environmental errors

c)

Observational errors

d)

All of the above

15.

Which of the following types of instrument can be used for D.C only?

a)

Moving iron attraction type

b)

Moving Iron repulsion type

c)

Permanent magnet type

d)

Hotwire type

16.

The household energy meter is

a)

An indicating instrument

b)

A recording instrument

c)

An integrating instrument

d)

None of the above

17.

Which of the following is caused by careless handling?

a)

Systematic error

b)

Gross error

c)

Random error

d)

None of the mentioned

18.

‘A system will be error free if we remove all systematic error’

a)

True

b)

False

19.

Which of the following error is caused by poor calibration of the instrument?

a)

Random error

b)

Gross error

c)

Systematic error

d)

Precision error

20.

Which of the following is not a fundamental quantity?

a)

Length

b)

Angle

c)

Time

d)

Luminous intensity