Font size
WorksheetsPotentiometric titration using quinhydrone electrode
Total questions: 23
Worksheet time: 13mins
Check all that is applicable to Quinhydrone
Bronze coloured needle shaped crystals
It is highly soluble in water .
It is equimolar mixture of Quinone and hydroquinone.
It is used in the determination of pH of the solution
It is a type of redox electrode
A ___________ wire electrode is immersed in a saturated aqueous solution of quinhydrone and given acid solution.
Silver
Copper
platinum
Aluminium
What is the Nernst equation for the reaction in the image displayed.
E cell = E0cell −20.059 log [a H+]2
E cell = E0cell +20.059 log [a H+]2
E cell − E0cell = 20.059 log [a H+]
E0cell = 20.059 log [a H+]2
Name the indicator electrode used in this experiment .
(a)
Name the reference electrode used in this experiment.
(a)
In the construction of the electrochemical cell, reference electrode is connected to the _____________terminal.
positive
negative
The potentiometer is calibrated by checking the potential of the inbuilt standard cell. The potential on the display should be _____________volts
1.0183
0.989
0.2415
0. 777
In this experiment Emf of the cell is obtained by the expression, Ecell = __________________
Equin- ESCE
Equin + ESCE
ESCE - Equin
ESCE + Equin
Electrode potential of Quinhydrone electrode depends on
Amount of Quinhydrone powder added
Amount of Quinhydrone powder added
Concentration of Hydrogen ions in the solution
the reference electrode used.
The standard electrode potential of quinhydrone electrode is
0.242 V
0.699V
0.771V
0.457 V
. pH of the acid solution is calculated using the formula
pH = ____________
pH=0,05916( 0.457 −Equin )
pH=0.05916( 0.457 −Ecell )
pH=0.05916( 0.457 −Eref )
Which of the following electrodes is not used to measure pH of a solution?
Glass electrode
Quinhydrone electrode
Standard Hydrogen Electrode
Hydrogen gas electrode
in the electrochemical cell representation, II indicates ,
cathode
anode
salt bridge
In the experiment , Calomel electrode is connected to
negative terminal
positive terminal
The quinhydrone electrode is set up by dissolving quinhydrone powder in the acid solution and inserting ________wire for electrical contact.
Platinum
silver
Neobium
tin
A pinch of the quinhydrone powder is added to the acid solution and stirred vigorously till it imparts
Red colour
greenish red colour
golden yellow colour
dark black colour
An electrode with a fixed potential is
anode
cathode
indicator electrode
reference electrode
Mercury covered by a layer of mercurous chloride in contact with saturated potassium chloride solution is a description of which of the following types of electrodes?
sodium
calcium
silver/silver chloride
calomel
In salt bridge KCl or KNO3 are used because......
they are highly soluble
they are electrolyte
ionic mobilities of ions are nearly same
they are cheap
The internal reference electrode in glass electrode is.....
SCE
glass membrane
mercury
Ag-AgCl
In quinhydron electrode there is equimolar mixture of
quinone and quinoline
quinone and hydroquinone
quinone and quinoid
hydroquinone and sodium hydroxide
Quinhydron electrode cannot be used in determination of pH when combined with SCE beyond the pH ------
2
4
14
8
Quinhydron electrode can not be use in the presence dil. HNO3 and unsaturated organic acids.
True
False