An integrated system of underground or overhead piping connected to a source of extinguishing agent or medium which when actuated by its automatic detecting device suppresses fire within the area protected even without human intervention.
Automatic Fire Suppression System
Approved Supervised Sprinkler System
Standpipe System
Fire Alerting System
A passageway from one building to another, or through or around a wall in approximately the same floor level.
Means of Egress
Exit
Horizontal Exit
Interstitial
A building unsafe in case of fire because it will burn easily or because it lacks adequate exits or fire escapes.
Fire Hazard
Fire Trap
Combustible
Nacelle
A compilation report of all approved submittals, test and acceptable forms of all fire protection and life safety features, which shall form part of the "as-built" documents turned over by the contractor to the building owner.
FSCR
FSCCR
FSEC
FSIC
A non liquid-tight transverse partition in a cargo tank.
Baffle
Curtain Board
Plenum
Bulkhead
A technique to resist corrosion on a metal surface by making the surface cathode of an electrochemical cell.
Damper
Detearing
Fulminate
Cathodic Protection
Any material which, by its nature or as a result of its reaction with other elements, produces a rapid drop in temperature of the immediate surroundings.
Flammable Finishes
Cyrogenic
Compressed Gas
Oxidizing Material
A mechanical device consisting of linkages and horizontal bars across a door, which when pushed from the inside will cause the door to open and facilitates exit from the building, structure or facility.
Panic Hardware
Safety Can
Vestibule
Derrick
A tank, vat or container of flammable or combustible liquid in which articles or materials are immersed for purposes of coating, finishing, treating, or similar processes.
Cryogenic Inground Container
Dip Tank
Cargo Tank
Electrostatic Fluidized Bed
A continuous membrane or a membrane with discontinuities created by protected openings with a specified fire protection rating, where such membrane is designed and constructed with a specified fire resistance rating to limit the spread of fire, that also restricts the movement of smoke.
Fire Wall
Fire Barrier
Fire Damper
Combination Fire and Smoke Damper
Standard for Fire Tests of Building Construction and Material
UL 1975
UL 263
UL 790
UL
Standard for Fire Retardant-treated wood and Fire Retardant Coatings for Building Materials
NFPA 703
NFPA 914
NFPA 5000
NFPA 1936
Hazardous Materials Code
NFPA 255
NFPA 409
NFPA 400
NFPA 664
Standard for Standard Test Methods of Fire Tests of Roof Coverings
ANSI/ASME B31.3
ANSI/IAS NGV1
ANSI/IIAR 7
ANSI/UL 790
Standard for the Installation of Sprinkler Systems
NFPA 13
NFPA 13R
NFPA 17
NFPA 17A
Any liquid having a flash point at or above 37.8 degree Celsius and below 60 degree Celsius.
Combustible Liquid
Class II Liquid
Class IIIA Liquid
Class IIIB Liquid
Check all the coverage for this RIRR
All persons, either natural or juridical
All buildings, facilities or structures and their premises, erected or constructed before and after the effectivity hereof
Design and installation of mechanical, electronics and electrical systems relative to fire protection
Manufacturing, storage, handling and/or use, and transportation of explosives and/or combustible/flammable liquids and gases, toxic and other hazardous materials and operations, and their wastes
All land transportation vehicles and equipment, ships or vessels docked at piers or wharves or anchored in seaports
Fires involving flammable liquids and gases.
Class A Fire
Class B Fire
Class C Fire
Class D Fire
Class K Fire
Liquid having flash points at or above 22.8 degree Celsius and below 37.8 degree Celsius.
Flammable Liquids
Class IA Liquid
Class IB Liquid
Class IC Liquid
Identify the grouping of these plastics:
Cellulosics (cellulose acetate, cellulose acetate butyrate, ethyl cellulose)
Chloroprene rubber
Fluoroplastics (ECTFE, ethylene-chlorotrifluoroethylene copolymer
ETFE, ethylene-tetrafluoroethylene copolymer
FEP, fluorinated ethylene-propylene copolymer)
Natural rubber (nonexpanded)
Nylon (nylon 6, nylon 6/6)
PVC (polyvinyl chloride greater than 5%, but not exceeding 15% plasticized)
Silicone rubber.
Group A Plastics
Group B Plastics
Group C Plastics
Liquids classified as non-flammable.
Class I Solvents
Class II Solvents
Class IIIA Solvents
Class IIIB Solvents
Class IV Solvents
A compressed natural gas-powered unit that has minimum acceptable safeguards against inherent fire hazards.
Type Designation CGH
Type Designation CN
Type Designation DX
Type Designation EX
Protective Enclosure of Exit. When an exit is required to be protected by separation from other parts of the building by some requirements of this RIRR, the construction of the separation shall have at least ____ hour fire resistance rating when the exit connects 3 storey or less, regardless of whether the storeys connected are above or below the storey at which the exit discharge begins.
1
2
3
4
Capacity of Means of Egress. Capacity factor for Health Care with sprinkler system for stairways (width per person).
7.6 mm
10.0 mm
15.0 mm
18.0 mm
Door minimum and maximum clear openings for means of egress.
700mm and 1000mm
750mm and 1100mm
710mm and 1220mm
800mm and 1200mm
When a door is required to be equipped with panic hardware by some other provisions of this Rule, the panic hardware shall cause the door latch to release when a force of not more than ____ is applied to the releasing device in the direction of exit travel.
5 kgf
7 kgf
8 kgf
9 kgf
Existing stairs minimum clear width.
700 mm
750 mm
815 mm
915 mm
New stairs minimum clear width for occupants greater than 2,000 persons.
1100 mm
1,120 mm
1,420 mm
1,500 mm
Maximum cross slope of ramps.
1:10
1:12
1:32
1:48
A combination of an automatic smoke detection system, automatic exhaust system, and an automatic water curtain.
Sprinkler Vent Method
Spray Nozzle Methods
Partial Enclosure Method
Occupant load for assembly area of concentrated use without fixed seats such as an auditorium, place of worship, dance floor, and lodge room.
0.46 sq.m
0.65 sq.m
1.40 sq.m
0.28 sq.m
The occupant load of residential occupancies in numbers of persons for whom exits are to be provided except in detached single and two-family dwellings shall be determined on the basis of one person per ____ gross floor area.
0.46 sq.m
1.20 sq.m
15.0 sq.m
18.6 sq.m
In hotels, what is the travel distance to exits from a guest room or guest suite to a corridor door in buildings not protected by an approved, supervised automatic sprinkler system?
30 m
23 m
38 m
10 m
Minimum height of a building to be considered a high-rise.
10.0 m
12.0 m
15.0 m
16.0 m
In Apartment buildings, the travel distance within any individual living unit to reach the nearest exit, or to reach an entrance door of the apartment which provides access through a public corridor to an exit on the same floor level.
12.0 m
15.5 m
31.0 m
46.5 m