wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Extraoral Radiographic Techniques 1

Total questions: 15

Worksheet time: 8mins

Name
Class
Date
1.

Panoramic radiograph causes a higher radiation dose than full mouth x-rays

a)

True

b)

False

2.

Magnification & distortion are major drawbacks of ...

a)

panorama

b)

periapical x-ray

c)

lateral cephalometric

d)

sialography

3.

During positioning the patient to take a panoramic x-ray, the frankfurt horizontal plane is ... to the floor

a)

parallel

b)

perpendicular

c)

it doesn't matter

d)

none of the above

4.

In Panoramic radiography, the x-ray tube and the film rotate in opposite directions

a)

True

b)

False

5.

In panoramic x-ray, an object will be sharp displayed when the central beam moves on this object with the same linear speed as on the film

a)

True

b)

False

6.

Three-dimensional curved zone or image layer in which structures are reasonably well defined

a)

Focal trough

b)

Digital radiography

c)

Biting fork

d)

Tomography

7.

If the patient doesn't swallow during taking a panoramic x-ray, a ... will be evident

a)

maxillary sinus

b)

palatopharyngeal air space

c)

nasopharyngeal air space

d)

palatoglossal air space

8.

1 panoramic image = ... intraoral images

a)

14

b)

16

c)

5

d)

3

9.

Digital panorama reduces the radiation by...

a)

15%

b)

20%

c)

25%

d)

30%

10.

On panoramic X-rays, the magnification coefficient depends on the distance between the ... and the ...

a)

sensor, object

b)

sensor, x-ray source

c)

object, x-ray source

11.

The magnitude of the horizontal distortion depends on ...

a)

distance between object & sensor

b)

distance between object & x-ray source

c)

distance between object & focal trough

d)

distance between x-ray source & focal trough

12.

In panoramic x-ray, if the structure of interest is displaced lingual to the beam, it passes ... through it, while buccal to the beam it passes ... though it

a)

more slowly, faster

b)

faster, more slowly

c)

faster, faster

d)

more slowly, more slowly

13.

Horizontal measurements made on panoramic radiograph are reliable

a)

True

b)

False

14.

As a result of the caudocranial inclination of the panoramic x-ray beam, the structures ... to the source appear ... on the image

a)

further from, lower

b)

further from, higher

c)

closer, lower

d)

closer, higher

15.

Two images of a single object which is located in the midline

a)

single real image

b)

double real image

c)

ghost image