The first step in manual film processing is:
development
rinsing
fixing
washing
drying
In manual film processing, the rinsing step is necessary because it:
removes the silver halide crystals from the emulsion
slows down the fixing process
removed the developer from the film and stops the development process
reduces the energized silver halide crystals to black metallic silver
The film emulsion is hardened during:
development
rinsing
fixing
washing
drying
The hydroquinone in the developer brings out the _______ tones, whereas the elon in the developer brings out the _____ tones on a dental radiograph.
balck; white
white; black
gray: gray
black; gray
The size of the darkroom is determined by the following factors except:
volume of radiographs processed
type of processing equipment used
humidity level of the room
number of persons using the room
Any light leaks of white light into the darkroom will cause
film fogging
film reticulation
overdevelopment of films
underdevelopment of films
Unopened boxes of radiographic film should not be stored in the darkrooms because
chemical fumes from the processing solutions may fog the film
continued exposure to the safelight is not recommended
the box may have a tear that may exposure the film
processing solutions could splash onto the box
The thermometer for manual processing should be placed in the
developer solution
water bath
fixer solution
all of the answers are correct
A replenisher is added to the processing solutions to:
compensate for the loss of solution strength
ensure uniform results between solution changes
compensate for the loss of volume of solution
compensate for oxidation
all of the answers are correct
How often should the processor be cleaned?
once per week
once per month
once per day
whenever the solutions are changed
Which word describes the processing error of - fogged film
dark
gray
white
light
Which word describes the processing error of - overdeveloped film?
light
dark
white
gray
Which word describes the processing error of - underdeveloped film?
light
dark
black
gray
Which word describes the processing error of - a light leak?
light
dark
black
white
Identify the processing error
developer cutoff
fixer spots
underdeveloped
damaged cracked emulsion
Identify the processing error
fixer spots
developer spots
air bubbles
fingernail artifact
Identify the processing error
developer spots
fixer cutoff
static electricity
developer cutoff
Identify the processing error
fingerprint artifact
fingernail artifact
light leak
fogged film
Identify the processing error
developer cutoff
light leak
static electricity
scratched film
Identify the processing error
static electricity
scratched film
fixer spots
overdeveloped film
Identify the processing error
over fixed film
overdeveloped film
fogged film
overlapped film
Calibration of dental x-ray equipment can be performed by a dentist, dental hygienist, or dental assistant.
True
False
Annual tests for dental x-ray machines can be performed by a dentist, dental hygienist or dental assistant
True
False
For quality control purposes, each new box of unopened film should be tested for film freshness and fogging before it is used.
True
False
After processing, fresh film that has been properly stored and protected will appear _________.
fogged
clear with a slight blue tint
clouded with a blue tint
totally black
One of the most critical areas of quality control that requires daily monitoring is ___________.
examination of the fluorescent bulbs inside the viewbox
cleaning the extraoral intensifying screens
examination of the darkroom for light-tightness
processing of films
The coin test is used to check ___________.
proper safelighting
strength of the processing solutions
film density
beam collimation
The following must be closely monitored with manual processing techniques.
temperature of the water bath
levels of the processing solutions
accuracy of the timer
accuracy of the thermometer
all of the answers are correct
On average, processing solutions should be replenished
once daily
once weekly
every 3-4 weeks
every 8-10 weeks
Fresh films and fresh chemicals must be used when preparing reference radiographs.
True
False
A reference radiograph is used to check ___________.
proper safelighting
light-tightness of the darkroom
strength of the fixer solution
strength of the developer solution
Regardless of who is actually exposes the patient to radiation, the dentist is ultimately responsible for the diagnostic quality of all dental images.
True
False
The clearing test is used to monitor __________.
developer strength
fixer strength
accuracy of the timer
film density
none of the answers are correct