Transformers are rated in_________.
kW
kV
kWH
kVA
In the computation of the size of building wire, the PEC requires that at least a certain percent increase must be added. What percent is this?
15%
20%
25%
50%
A device designed to open and close a circuit by nonautomatic means and to open the circuit
automatically on a predetermined overcurrent without damage to itself when properly applied
within its rating.
Circuit breaker
disconnect
relay
switch
Installations under ground or in concrete slabs or masonry in direct contact with the earth; in
locations subject to saturation with water or other liquids, such as vehicle washing areas; and
in unprotected locations exposed to weather.
Moist Location
Wet Location.
proof location
Dry Location
What shall be the minimum size of conductor for signage?
2.0 sq mm.
3.5 sq. mm
5.5 sq mm
8.0 sq mm
At least _____wall switch-controlled lighting outlet shall be installed in every habitable room
and bathroom.
one
two
three
none
Circuits used only for the operation of fire alarm, other protective signaling systems, or the
supply to fire pump equipment _________to be connected on the supply side of the service
overcurrent device where separately provided with overcurrent protection
not stated in the code
shall not be permitted
not required by the Code
shall be permitted
The code ______the use of a raceway as a means of support for nonelectric equipment,
such as suspended ceilings, water pipes, nonelectric signs, and the like, which could cause a
mechanical failure of the raceway.
allows
prohibits
does not mentioned
does not detail
Determine the minimum-size service conductors to supply a 100 A lighting and appliance
load plus three squirrel-cage induction motors rated 460 volts, 3 phase, 40°C, full-voltage
starting one 100-hp rated at 124 A at full load and two 25-hp motors rated at 34 A at full load
on a 480-volt, 3-phase system.
223 A
155 A
323 A
292 A
If the service point is specified as “at the pole” by the utility, then the service-drop conductors
are considered
service conductor
service head
service mast
service mast
A switch or circuit breaker in a wet location or outside of a building shall be enclosed in a
________enclosure or cabinet. Switches shall not be installed within wet locations in tub or
shower spaces unless installed as part of a listed tub or shower assembly.
waterproof
weatherproof
concealed
accesible
Items in the Code that identify actions that are specifically required or prohibited are considered which of the following:
Permissive rules
Mandatory rules
Guidelines for examination of installation
Permitted use
Which of the following installations are covered by the Electrical Code:
Power wiring for a large industrial machine
Computer wiring in an office building
Telephone cable in a flexible duct
All the above
Unless otherwise specified, live parts for electrical equipment operating at ____ volts or more shall be guarded.
50
100
150
200
Conductor sizes are listed in which of the following:
Circular mils
Diameter or thickness
AWG or millimeters
AWG or circular mils
An insulated conductor assembly with fittings and conductor terminations that is completely enclosed in a ventilated protective metal housing is called which of the following:
A raceway
A cablebus
A busbar
A busway
For a 30 amp receptacle connected to a 30 amp branch circuit supplying two or more outlets, the total cord-and-plug load may not exceed which of the following sizes:
12 amps
15 amps
16 amps
24 amps
A 15 amp receptacle that is installed in a wet location must meet which of the following installation requirements:
Be protected from rain or water runoff
Have an attachment plug cap inserted
Have an enclosure that is weatherproof
All of the above
A factor that would affect conductor ampacity is which of the following:
The conductor length
Voltage
Temperature
Motor size
Which of the following has the highest electrical resistance:
Water
Paper
Iron
Brass