WorksheetsFn-Exam
Total questions: 55
Worksheet time: 2hrs 44mins
What type of sprinkler head is this?
UPRIGHT
PENDENT
HORIZONTAL SIDE WALL
VERTICAL SIDEWALL
What type of sprinkler head is this?
UPRIGHT
PENDENT
HORIZONTAL SIDEWALL
VERTICAL SIDEWALL
What type of sprinkler head is this?
UPRIGHT
PENDENT
HORIZONTAL SIDEWALL
VERTICAL SIDEWALL
What type of sprinkler head is this?
UPRIGHT
PENDENT
HORIZONTAL SIDEWALL
VERTICAL SIDEWALL
Which is a WASH DOWN
Which is a REVERSE TRAP
Which is a SIPHON JET
Which is a SIPHON VORTEX
Areas in which all occupants
are ambulant and are able to move unaided
away from a fire. E.g. outpatient department,
service areas or zones
Life Risk areas
High Risk areas
High fire load areas
High life Risk areas
Areas which, because
of their construction or contents, contain huge
amount of combustible materials, thereby
constituting a fire load in excess of that
normally found. e.g. gas storage, linen closets.
Life Risk areas
High Risk areas
High fire load areas
High life Risk areas
Areas which, due to their
function are more usually susceptible to an
outbreak of fire, or to a rapid spread of fire or
smoke. E.g. kitchen , boiler room.
Life Risk areas
High Risk areas
High fire load areas
High life Risk areas
Areas in which persons
may reside and are not able to move unaided
away from a fire. E.g. – intensive care unit,
operating department.
Life Risk areas
High Risk areas
High fire load areas
High life Risk areas
Systems that have open
sprinklers, i.e. the heat sensing operating element
is removed during installation, so that all sprinklers
connected to the water piping system are open.
WET PIPE SYSTEM
DRY PIPE SYSTEM
DELUGE SYSTEM
Water is not present in the piping until the system
operates. The piping is pressurized with air, at a
"maintenance" pressure which is relatively low
compared with the water supply pressure.
WET PIPE SYSTEM
DRY PIPE SYSTEM
DELUGE SYSTEM
An automatic water supply provides water
under pressure to the system piping. All of
the piping is filled with water. Until sufficient
heat is applied, causing one or more
sprinklers to fuse (open), the automatic
sprinklers prevent the water from being
discharged.
WET PIPE SYSTEM
DRY PIPE SYSTEM
DELUGE SYSTEM
Type of venting system where the vent connects with
a single fixture trap, usually at the back and
extends vertically and connects with a stack vent, a
vent stack or branch vent.
VENT STACK
STACK VENT
INDIVIDUAL VENT
CIRCUIT VENT
The extension to the open air of a soil or waste stack
above the highest horizontal branch drain or fixture
branch connected to the stack.
VENT STACK
STACK VENT
INDIVIDUAL VENT
CIRCUIT VENT
A vertical vent pipe installed primarily for the
purpose of providing circulation of air to
or from any part of the building
drainage system.
VENT STACK
STACK VENT
INDIVIDUAL VENT
CIRCUIT VENT
A branch vent which serves two or more traps
and extends from in front of the last fixture
connection of a horizontal branch to the vent stack.
VENT STACK
STACK VENT
INDIVIDUAL VENT
CIRCUIT VENT
Which is a GATE VALVE
Which is a ANGLE VALVE
Which is a CHECK VALVE
Which is a GLOBE VALVE
Vent used for underground public restrooms.
LOOPED VENT
WET VENT
UTILITY VENT
LOCAL VENT
Vent used on fixtures which are located
in the room away from partitions that
might be utilized to conceal the waste
and vent
LOOPED VENT
WET VENT
UTILITY VENT
LOCAL VENT
– A ___ vent is a method of
ventilation used rather extensively
for small groups of bathroom
fixtures
– A portion of the vent system
through which liquid wastes flow
LOOPED VENT
WET VENT
UTILITY VENT
LOCAL VENT
- A vent without connection with the plumbing system
– It terminates at the roof and connected to the
fixture at point below the seat
LOOPED VENT
WET VENT
UTILITY VENT
LOCAL VENT
Which are ELBOW fittings
Which is a UNION fitting
Which is a WYE fitting
Which are TEE fittings
A coupling is a pipe fitting used to stop leakages in broken or damaged pipes. The pipes to be connected should be of the same diameter. The two kinds of couplings used in plumbing are regular coupling and slip coupling.
This type of pipe fitting is almost similar to coupling in terms of functions, but just with a difference, i.e. a union can be removed easily any time while the coupling cannot. A variety of dielectric unions are used to join pipes made of different materials to avoid any kind of galvanic corrosion between them. These pipe fittings comprise of a nut, female and male ended threads.
Adapters are connected to pipes to either increase their lengths or if pipes do not have appropriate ends. These pipe fittings make the ends of the pipe either male or female threaded as per the need.
This pipe setting is used to reduce the flow size of the pipe from the bigger to smaller one. There are two kinds of reducers- concentric reducer and eccentric reducer. The former one is in the shape of a cone used for gradual reducing of the size of the pipe. The latter one has its one edge facing the mouth of the connecting pipe reducing the chances of air accumulation.
Which is a REDUCER
Which is a COUPLING
Which is a ADAPTER
Usually located along the entire perimeter of the roof.
DOWNSPOUT
GUTTER
ROOF DRAIN
CATCH BASIN
Located every 8 to 10 meters & at every corner of the roof.
DOWNSPOUT
GUTTER
ROOF DRAIN
CATCH BASIN
Drain designed to receive water collecting on
the surface of a roof and to discharge it into a
downspout. Designed to prevent clogging.
DOWNSPOUT
GUTTER
ROOF DRAIN
CATCH BASIN
Downspouts should terminate in a catch basin (can serve more than one
downspout). Delivers water to the sewers in the street via gravity.
DOWNSPOUT
GUTTER
ROOF DRAIN
CATCH BASIN
(a) is used for fixtures where grease may be introduced into the drainage or sewer system in quantities that can effect line stoppage or hinder sewage treatment or private sewage disposal.
Solid organic matter that are denser than water and
settle at the bottom of the septic tank.
SLUDGE
SCUM
EFFLUENT
Liquid content of sewage
SLUDGE
SCUM
EFFLUENT
lighter organic material that rise to the surface of the
water
SLUDGE
SCUM
EFFLUENT
Bacteria found in the Septic Tank that can survive in places without
oxygen.
AEROBIC BACTERIA
ANAEROBIC BACTERIA
EFFLUENT
Bacteria found in the Septic Tank that relies on oxygen to survive.
AEROBIC BACTERIA
ANAEROBIC BACTERIA
EFFLUENT
Waste water with the exception of human wastes. From laundries, wash basins, sinks, and tubs, etc.
GREY WATER
BLACK WATER
STROM WATER
Waste water that contain solid and liquid human wastes.
GREY WATER
BLACK WATER
STROM WATER
Waste water that is only Rainwater.
GREY WATER
BLACK WATER
STROM WATER
Class _ fires involving solid materials such as wood, paper or textiles.
A
B
C
D
Class _ fires involving flammable liquids such as petrol, diesel or oils.
A
B
C
D
Class _ fires involving metals.
A
B
C
D
Which type of Mechanical fire detection is shown in the picture.
Manual alarm system
BELL connected to alarm system
Signal Lights connected to alarm system
Electronic alarm system