wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

9189 P1 Hot water

Total questions: 16

Worksheet time: 8mins

Name
Class
Date
1.

Which of these is NOT a key factor when designing a hot water system

a)

Number of outlets

b)

Type of fuel

c)

Running costs and efficiently

d)

Water pressure

e)

water hardness or softness

2.

What is the correct description of a centralised hot water system

a)

Hot water is delivered from a central point to all HW outlets in the building

b)

Hot water is delivered form a point close to the appliance and only supplies that appliance

3.

What building regulation approved document covers hot water safety and water efficiently

a)

G

b)

F

c)

H

d)

A

4.

What regulation covers insulation and performance of Hot water cylinders

a)

Approved document L1

b)

Approved document G3

c)

water regulations 1999

d)

Approved documents P

5.

This picture shows?

a)

A direct cylinder

b)

An Indirect cylinder

c)

A combination Cylinder

d)

A prismatic cylinder

6.

What is the max temperature of water on a bath in a new build home?

a)

43

b)

60

c)

48

d)

38

7.

An electric shower is a form of?

a)

Direct single point hot water

b)

Indirect single point hot water

c)

Indirect multi point hot water

d)

Direct multi point hot water

8.

A hot water cylinder connected to the main water supply is know as a?

a)

Unvented cylinder

b)

Indirect cylinder

c)

Direct cylinder

d)

Boiler

9.

What British standard covers Hot water installation?

a)

BS6700

b)

BS1212 part 2

c)

BSEN806

d)

BSEN6700

10.

The minimum size of vent pipe is?

a)

15mm

b)

28mm

c)

22mm

d)

The same size as the cold feed pipe

11.

Too prevent one pipe circulation the vent pipe must step across by how many mm.

a)

150mm

b)

300mm

c)

450mm

d)

600mm

12.

This picture shows a?

a)

Immersion heater

b)

Surry flange

c)

Essex flange

d)

Cylinder thermostat

13.

Building regulation part L states that all pipe work within what distance of the cylinder needs to be lagged?

a)

2m

b)

1.5m

c)

1m

d)

450mm

14.

The thermostats on a hot water cylinder should be set at?

a)

48 to 55 degrees C

b)

43 to 70 degrees C

c)

48 to 60 degrees C

d)

60 to 65 degrees C

15.

The cylinder stat is placed how far up the cylinder?

a)

one-quarter of the way

b)

one-third of the way

c)

one-half of the way

d)

two-thirds of the way

16.

The unvented system requires other mechanical safety devices for the safe control of the expansion of water and to ensure that the water within the storage cylinder does not exceed?

a)

60

b)

85

c)

100

d)

143.5