wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Plumbing L3 AP Drainage systems PT1

Total questions: 18

Worksheet time: 9mins

Name
Class
Date
1.

What building regulations cover drainage systems?

a)

Part L and J

b)

Part H and G

c)

Part H and P

d)

Part G and L

2.

The British standard that cover gravity drainage systems within the building is?

a)

BS 12056

b)

BS 1212

c)

BSEN 806

d)

BS 6700

3.

The British standard for good workmanship on site is?

a)

BS 8000 pt13

b)

BSEN 806

c)

BS 1212

d)

BS 1172

4.

This picture shows a?

a)

Primary ventilated stack

b)

Secondary ventilated stack

c)

Soil pipe

d)

Drain pipe

5.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

6.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

7.

This picture shows a?

a)

Waste manifold

b)

Long radius bend

c)

Strap boss

d)

intumescent collar

8.

The lowest connection to the soil stack must be a minimum of how many mm for a two story building?

a)

150 mm

b)

300 mm

c)

450 mm

d)

750 mm

9.

The lowest connection to the soil stack must be a minimum of how many mm for a five story building?

a)

150 mm

b)

300 mm

c)

450 mm

d)

750 mm

10.

Where a trap diameter is 50mm or above, the trap seal must be a minimum of?

a)

50 mm

b)

25 mm

c)

75 mm

d)

100 mm

11.

The minimum size of trap for a shower is?

a)

40 mm

b)

32 mm

c)

50 mm

d)

100 mm

12.

If the stack has a tight radius at the base (instead of a long radius bend) the water can start to back up the stack, causing pressure to build, and pushing out the lower traps. This is known as?

a)

Compression

b)

Self siphonage

c)

induced siphonage

d)

capillary action

13.

What is the recommended gradient for a bath waste pipe?

a)

18 mm

b)

18 to 22 mm

c)

18 to 90 mm

d)

no recommended gradient

14.

What is the maximum length for a 32 mm basin waste?

a)

1.7 m

b)

1.5 m

c)

3 m

d)

6 m

15.

Why is this plastic waste pipe sagging so badly?

a)

it's in a sunny location

b)

no room for exapansion

c)

it's not clipped correctly

d)

all of the above

16.

The correct gradient a gutter should be installed to is?

a)

600:1

b)

1:60

c)

1:600

d)

60:1

17.

This gutter profile is called......

a)

Half round

b)

Square

c)

Egg mould

d)

Ogee

18.

One purpose of installing gutter systems to a gradient is to...

a)

allow for expansion of the gutter system

b)

ensure the gutter system looks good when it is finished

c)

make it easier for us to install gutter systems

d)

help create a self cleaning flow of water through the gutter system