wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Central Heating 6035-02 | Part 4

Total questions: 40

Worksheet time: 20mins

Name
Class
Date
1.

What is the 'main purpose' of central heating within a property?

a)

Providing a means of thermal comfort

b)

Heating up the primary circuit within the hot water system

c)

Provide adequate heating for one specific room

d)

To prevent other pipework within the property from freezing

2.

What british standard covers the installation and commissioning of water based heating systems?

a)

BS 8000

b)

BS 4488

c)

BS EN 12828

d)

BS EN 14336

3.

Benefits of having a air separator is? (Choose 2)

a)

Reduced noise in system

b)

Prevents limescale

c)

Lower risk of corrosion

d)

Lower risk of debris in system

4.

Which Building Regulation covers the heat producing appliances?

a)

Part J

b)

Part K

c)

Part L

d)

Part P

5.

Why is an automatic bypass valve included on a Y-plan and S-plan system?

a)

Allow water to flow through boiler when the circuits close down

b)

Bypassing pressure preventing the system from a "lock out"

c)

It prolongs the circulators lifespan

d)

All of the above

6.

The three port diverter valves are commonly found in combination boilers and some older systems. What is the system plan known as?

a)

S-plan

b)

Y-plan

c)

Z-plan

d)

W-plan

7.

Approximately how far away from the heat source is the room thermostat situated?

a)

1.5 metres

b)

2 metres

c)

3 metres

d)

4.5 metres

8.

Saving on such things as energy and fuel bills, along with producing less CO² emissions are all beneficial factors to having?

a)

The correct clipping distances

b)

The correct insulation

c)

The correct pipe sizes

d)

All of the above

9.

STATEMENT: The sealed system in not open to atmosphere and incorporates a sealed expansion vessel.

a)

True

b)

False

10.

What system is fed directly from the mains and incorporates an expansion vessel capable of taking up any expansion within the system?

a)

Low pressure, open vented system

b)

Sealed, pressureised system

11.

What is the component shown here?

a)

3-port motorised valve

b)

2-port motorised valve

c)

Electrical-lever service valve

d)

Electrical scale inhibitor

12.

Which of the following is an advantage to having the two pipe semi gravity system installed?

a)

Uncontrolled heat throughout the system

b)

All heat emitters reach the same temperature

c)

The system does not comply with Building Regulations part L

d)

The boilers connected to these systems are of low efficiency

13.

Which of the following were defining factors to why the full gravity systems are no longer installed today?

a)

Incorrect fall in pipework would cause the system to not work properly

b)

Longer heat-up times compared to 'newer' systems

c)

The system did not run off of any pumps

d)

All of the above

14.

What is the British Standard for the specification for radiators and convectors?

a)

BS EN 442

b)

BS 4422

c)

BS 6700

d)

BS EN 14336

15.

The colour of light graded low carbon steel is labelled as?

a)

Yellow

b)

Brown

c)

Blue

d)

Red

16.

Which of the following is an advantage of the condensing boilers?

a)

Higher maintenance

b)

Disposal of acid condensate

c)

Part L compliant

d)

Uses more gas out of 'condensate mode'

17.

The three port mid-position valve is labeled with AB, A and B. But what is the AB for?

a)

Flow for the boiler

b)

Hot water

c)

Central heating

18.

What is the minimum height the open vent must rise above the water level on the F&E?

a)

350mm

b)

400mm

c)

450mm

d)

500mm

19.

BS 1192 recognises the symbol shown here as?

a)

Drain off valve

b)

Single check valve

c)

Automatic air vent

d)

Radiator valve

20.

Which of the following is for the engineer to balance the system on a radiator?

a)

Wheel head valve

b)

Thermostatic radiator valve

c)

Lock shield valve

21.

What is the component shown?

a)

Radiator key

b)

Radiator valve spanner

c)

Radiator bleed key

d)

Allen key

22.

The Thermostatic radiator valve reacts to what to close off the valve when the system is up to the correct heat?

a)

Background heat temperature

b)

Latent heat temperature

c)

Passive heat temperature

d)

Ambient air temperature

23.

The skirting convector has a finned copper heat exchanger but relies on what?

a)

A natural convection, offering background heating

b)

A larger area to heat properly

c)

A kitchen unit to have a grill mounted on the kick plinth

d)

The property to be planned for a retro-fit before being installed

24.

STATEMENT: Depending the temperature of water flowing through plastic pipework will determine how far apart the clipping distances are. The hotter the water, the closer the clips.

a)

True

b)

False

25.

Which of the following is the lock shield valve?

a)
b)

c)

26.

Which of the following is described as, allows the heated water in the system to expand and operate at atmospheric pressure.

a)

Cold water storage cistern

b)

Feed and expansion cistern

c)

Combination unit

d)

Unvented cylinder

27.

What is the cause for the iron oxidating within the central heating system?

a)

Aeration occuring in the system

b)

Electrolytic corrosion occurring

c)

The boiler reaching extreme temperatures

d)

The system having a leak occur within the heat exchanger(coil)

28.

What component is described as, to allow close proximity/close coupled pipework when positioning the cold feed and vent pipe.

a)

Galvanic cell scale inhibitor

b)

Line strainer

c)

Air separator

d)

Circulator

29.

The 'neutral point' of a H frame is at the base of the cold feed pipe from the F&E cistern. How far from the open vent pipe is the 'neutral point'?

a)

100mm

b)

150mm

c)

300mm

d)

450mm

30.

What is situated one-third of the way up a hot water cylinder?

a)

Immersion heater

b)

Essex flange

c)

Surrey flange

d)

Cylinder thermostat

31.

What is the component shown?

a)

Galvanic cell scale inhibitor

b)

Boiler thermostat

c)

Chemical inhibitor

d)

Magnetic system cleaner

32.

What height do manufacturers recommend that radiators should be fitted?

a)

150mm from floor height 

b)

200mm from floor height

c)

250mm from floor height

d)

300mm from floor height

33.

Half hard straight lengths are what grade of copper?

a)

R220

b)

R250

c)

R290

34.

Which of the following is used with heavy low carbon steel pipes?

a)

Steam and fire systems

b)

Heating and oil lines

c)

Gas

35.

The dry side of the expansion vessel's rubber membrane is charged through a schrader valve to what pressure?

a)

60psi

b)

1bar

c)

1.5bar

d)

2bar

36.

STATEMENT: The solid fuel used on a two pipe semi gravity with heat sink are more controllable than boilers using gas or oil.

a)

True

b)

False

37.

Of the following, which is NOT an advantage to having a C plan two pipe semi gravity system?

a)

Boilers fitted to this system can tend to be a lower efficiency

b)

There is full control for both heating and hot water

c)

Each heat emitters reach the same temperature

d)

The system is compliant with Building Regulations L1b

38.

The condensing boilers allow gases to pass over a second heat exchanger, cooling to what temperature?

a)

45°C

b)

50°C

c)

55°C

d)

60°C

39.

The phrase used for how plumbers/engineers balance the central heating system is known as?

a)

Level radiator method

b)

Balance radiator method

c)

Rule of thumb method

d)

Efficiency saver method

40.

What type of insulation is shown here?

a)

Foil wrapped

b)

Flexible polyethylene

c)

Felt lagging

d)

Polyisocyanurate foam