part of the drainage system beginning just outside the foundation wall and terminating at the main sewer. The terminal of a house sewer can also be a septic tank.
HOUSE SEWER
HOUSE DRAIN
House Trap
DRAINAGE SYSTEM
part of the plumbing system which receives the discharge of all soil and waste stacks within the building and conveys it to the house sewer (referred to as the collection line)
HOUSE SEWER
HOUSE DRAIN
House Trap
DRAINAGE SYSTEM
a device placed in the house drain immediately inside the foundation wall of the building; serves as barrier; prevents gases which occur in the public sewers from circulating through the plumbing system.
HOUSE SEWER
HOUSE DRAIN
House Trap
DRAINAGE SYSTEM
takes the waste water from the plumbing fixtures and deliver it to the sewer
HOUSE SEWER
HOUSE DRAIN
House Trap
DRAINAGE SYSTEM
water supply, liquids, substances and other ingredients (water, liquid, and other carried wastes); the fixture, fixture traps; the soil, waste, vent pipes; house drain, foundation drain, house sewer; storm water drainage, drainage ejectors, appurtenances and connections
PLUMBING SYSTEM
SEWERAGE, SEWERAGE WORKS
BUILDING SUBDRAIN
SUBSOIL DRAIN
- (construction, collection, transportation, pumping treatment and final disposition of sewage
PLUMBING SYSTEM
SEWERAGE, SEWERAGE WORKS
BUILDING SUBDRAIN
SUBSOIL DRAIN
underground system; cannot
drain by gravity into the building sewer
PLUMBING SYSTEM
SEWERAGE, SEWERAGE WORKS
BUILDING SUBDRAIN
SUBSOIL DRAIN
underground drainpipe; receives only subsurface or seepage water and convey it to a sump for disposal by gravity flow or by lift pump
PLUMBING SYSTEM
SEWERAGE, SEWERAGE WORKS
BUILDING SUBDRAIN
SUBSOIL DRAIN
lowest horizontal
piping of drainage system; conveys to the building
sewer beginning 0.6 m. outside the building wall
BUILDING DRAIN (HOUSE DRAIN)
BUILDING SEWER (HOUSE SEWER)
HOUSE DRAIN
HOUSE SEWER
starts at the
end of the building drain
BUILDING DRAIN (HOUSE DRAIN)
BUILDING SEWER (HOUSE SEWER)
HOUSE DRAIN
HOUSE SEWER
part of the lowest horizontal piping of a plumbing system; conveys it to the house sewer
BUILDING DRAIN (HOUSE DRAIN)
BUILDING SEWER (HOUSE SEWER)
HOUSE DRAIN
HOUSE SEWER
part of plumbing system extending from about 4 or 5’ from inner face of foundation wall
BUILDING DRAIN (HOUSE DRAIN)
BUILDING SEWER (HOUSE SEWER)
HOUSE DRAIN
HOUSE SEWER
one fixture unit equivalent to a flow rate of 7 ½ gallons of water per min; 28.3 liters per min (1 cu.ft/minute)
FIXTURE UNIT
PLUMBING UNIT
FIXTURE DRAIN
Trap
minimum standard quantity of one (1) water meter, one (1) water closet, one (1) lavatory, one (1) shower head and drain for a bathtub or shower stall, one (1) kitchen sink, one (1) laundry tray and three (3) floor drains and four (4) faucets/hose bib
FIXTURE UNIT
PLUMBING UNIT
FIXTURE DRAIN
Trap
the drain from the trap of a fixture to the junction of the drain
FIXTURE UNIT
PLUMBING UNIT
FIXTURE DRAIN
Trap
a device to prevent the passage of sewer air through it; also called anti-siphon traps
FIXTURE UNIT
PLUMBING UNIT
FIXTURE DRAIN
Trap
vertical distance between the dip and the crown weir of a trap/the water in the trap between the dip and the crown weir
SEAL
TRAP
TRAP ARM
TRAP SEAL (WATER SEAL)
a fitting or device so constructed as to prevent the passage of air, gas
SEAL
TRAP
TRAP ARM
TRAP SEAL (WATER SEAL)
that portion of a fixture drain between a trap and the vent
SEAL
TRAP
TRAP ARM
TRAP SEAL (WATER SEAL)
maximum vertical depth of liquid that a trap will retain, measured within the crown weir and the top of the dip of the trap
SEAL
TRAP
TRAP ARM
TRAP SEAL (WATER SEAL)
portion of the plumbing system which receives the discharge of water closets
SOIL PIPE
WASTE PIPE
RECEPTOR
SPECIAL WASTE
part of the drainage system which conveys the discharge of fixtures other than water closets, such as sinks, lavatories, urinals, bathtubs; usually smaller in Ф than soil pipe
SOIL PIPE
WASTE PIPE
RECEPTOR
SPECIAL WASTE
approved plumbing fixture/device to adequately receive discharge from indirect waste pipes
SOIL PIPE
WASTE PIPE
RECEPTOR
SPECIAL WASTE
require special methods of handling (use of indirect waste piping and receptors, corrosion resistant piping, sand, oil or grease interceptors, condensers or other pre-treatment facilities
SOIL PIPE
WASTE PIPE
RECEPTOR
SPECIAL WASTE
intercept or to separate, and prevent the passage of oil, grease, sand
(CLARIFIER)
GREASE INTERCEPTOR
GREASE TRAP
SAND INTERCEPTOR
interceptor of 3 cubic meters capacity
(CLARIFIER)
GREASE INTERCEPTOR
GREASE TRAP
SAND INTERCEPTOR
device to retain grease from one to four fixtures (maximum)
(CLARIFIER)
GREASE INTERCEPTOR
GREASE TRAP
SAND INTERCEPTOR
(INTERCEPTOR)
(CLARIFIER)
GREASE INTERCEPTOR
GREASE TRAP
SAND INTERCEPTOR
- physical separation into indirect waste receptor from fixture, device indirectly connected
AIRBREAK
AIR GAP, DRAINAGE
AIR GAP, WATER DISTRIBUTION
DOUBLE-BEND FITTING
INDIRECT WASTE PIPE
unobstructed vertical distance between the lowest opening from any pipe to the flood level rim of the receptor
AIRBREAK
AIR GAP, DRAINAGE
AIR GAP, WATER DISTRIBUTION
DOUBLE-BEND FITTING
INDIRECT WASTE PIPE
unobstructed vertical distance through free atmosphere between the lowest opening from any pipe or faucet conveying potable water to the flood-level rim
AIRBREAK
AIR GAP, DRAINAGE
AIR GAP, WATER DISTRIBUTION
DOUBLE-BEND FITTING
INDIRECT WASTE PIPE
fitting shaped like the “S”
AIRBREAK
AIR GAP, DRAINAGE
AIR GAP, WATER DISTRIBUTION
DOUBLE-BEND FITTING
INDIRECT WASTE PIPE
a waste pipe that does not connect directly with the building drainage
AIRBREAK
AIR GAP, DRAINAGE
AIR GAP, WATER DISTRIBUTION
DOUBLE-BEND FITTING
INDIRECT WASTE PIPE
inadequate ventilation of the trap/subsequent (-) and (+) pressures
Trap Seal Loss
Retardation of Flow in Drainage System
Material Deterioration and Removal of Objectionable Gases
improper atmospheric conditions due to insufficient ventilation, or incorrect installation of fittings
Trap Seal Loss
Retardation of Flow in Drainage System
Material Deterioration and Removal of Objectionable Gases
wastes of the plumbing system contain chemical elements creating compounds of acid nature detrimental to piping materials
Trap Seal Loss
Retardation of Flow in Drainage System
Material Deterioration and Removal of Objectionable Gases
minus pressure in the drainage system
Siphonage
Back Pressure
Evaporation
Capillary Action
Wind Effects
plus pressure; blows the water out of the fixture into the room; at those located at the base of soil stacks, or a soil pipe changes its direction abruptly.
Siphonage
Back Pressure
Evaporation
Capillary Action
Wind Effects
use of deep seal trap recommended to prolong the interval of total loss of the trap seal
Siphonage
Back Pressure
Evaporation
Capillary Action
Wind Effects
a suspension of a foreign object (rag, string, lint) into the trap seal
Siphonage
Back Pressure
Evaporation
Capillary Action
Wind Effects
wind passing over the top of soil pipe roof terminal; a downdraft ripples the liquid content
Siphonage
Back Pressure
Evaporation
Capillary Action
Wind Effects
found in unventilated traps serving oval- bottomed fixtures (lavatory, slop sink); result of unequal atmospheric conditions caused by the rapid flow of water to the trap
Direct Self-Siphonage
Indirect or Momentum Siphonage
Siphonage by Momentum
the result of a minus ressure in the waste piping caused by discharge of water from a fixture installed on a line which serves a fixture placed at lower elevation
Direct Self-Siphonage
Indirect or Momentum Siphonage
Siphonage by Momentum
the result of a minus pressure in the waste piping caused by discharge of water from a fixture installed on a line which serves a fixture placed at lower elevation
Direct Self-Siphonage
Indirect or Momentum Siphonage
Siphonage by Momentum
used to ventilate the soil and waste pipes portion of the soil-pipe stack above the highest installed fixture branch extending through the roof.
the extension of a soil or waste stack above the highest horizontal drain connected to the stack (SVTR).
MAIN SOIL AND WASTE VENT (STACK VENT)
MAIN VENT (VENT STACK)
VENT SYSTEM
VENT PIPE
“relief” and “yoke” vents; tributary; collecting vent line; relieves any back-pressure; terminates in the soil-pipe stack, at least 3’ above the highest installed fixture branch size: 2 – 5” Ф.
vertical vent pipe.
principal artery
MAIN SOIL AND WASTE VENT (STACK VENT)
MAIN VENT (VENT STACK)
VENT SYSTEM
VENT PIPE
provide flow of air to or from a drainage system; provide a circulation of air to protect traps seals from siphonage and backpressure
MAIN SOIL AND WASTE VENT (STACK VENT)
MAIN VENT (VENT STACK)
VENT SYSTEM
VENT PIPE
a pipe or opening used for ensuring the circulation of air in a plumbing system; for reducing the pressure exerted on trap seals
MAIN SOIL AND WASTE VENT (STACK VENT)
MAIN VENT (VENT STACK)
VENT SYSTEM
VENT PIPE
horizontal wet venting of one or more sinks/floor drains by a common horizontal waste and vent pipe
COMBINATION WASTE AND VENT
CONTINUOUS WASTE
SIPHONAGE
VACUUM
drain connecting the compartments of a set of fixtures to a trap or connecting other permitted fixtures to a common trap
COMBINATION WASTE AND VENT
CONTINUOUS WASTE
SIPHONAGE
VACUUM
a suction created by the flow of liquids in pipes (pressure less than atmospheric)
COMBINATION WASTE AND VENT
CONTINUOUS WASTE
SIPHONAGE
VACUUM
an air pressure less than atmospheric (SIPHONAGE)
COMBINATION WASTE AND VENT
CONTINUOUS WASTE
SIPHONAGE
VACUUM
(Chapter 9 Sec. 903 Materials, NPCP)
Materials Used
Required Sizes of Vents
Vent Pipe Grades & Connections
(Chapter 9 Sec. 904 Size of Vents, NPCP)
Materials Used
Required Sizes of Vents
Vent Pipe Grades & Connections
& Connections: Vent pipe must be graded slightly so that no water may accumulate in it. (Chapter 9 Sec. 905 Vent Pipe Grades and Connections, NPCP)
Materials Used
Required Sizes of Vents
Vent Pipe Grades & Connections
back vent; serves a single trap
Individual Vent
Unit Vent
Circuit or Loop Ventilation
Relief Ventilation
ventilates two fixture traps; discharge into a sanitary cross with deflectors
Individual Vent
Unit Vent
Circuit or Loop Ventilation
Relief Ventilation
ventilates 2 or more fixture traps that discharge into a horizontal soil or waste branch extended at slight grade
Individual Vent
Unit Vent
Circuit or Loop Ventilation
Relief Ventilation
eliminates minus and plus pressures in the drainage system; on long vertical pipes, a relief vent, often referred to as yoke or by-pass vent maybe installed at 3 – 5 floor intervals
Individual Vent
Unit Vent
Circuit or Loop Ventilation
Relief Ventilation
vent pipe through which wastes flow
Wet Ventilation
Looped Vent
Local Vent
Utility Vent
used on fixtures located in the room away from partitions that might be utilized to conceal the waste and vent.
Wet Ventilation
Looped Vent
Local Vent
Utility Vent
a conduit/pipe shaft used to convey foul odours from a fixture or room; used to some extent in connection with water closets; terminates at the roof
Wet Ventilation
Looped Vent
Local Vent
Utility Vent
used for underground public restrooms
Wet Ventilation
Looped Vent
Local Vent
Utility Vent
connects directly with an individual trap underneath/behind the fixture (INDIVIDUAL VENT/REVENT PIPE)
INDIVIDUAL
BACKVENT PIPE
UNIT VENT
BRANCH VENT
DRY VENT
WET VENT
an arrangement of venting so installed that one vent pipe will serve two traps
BACKVENT PIPE
UNIT VENT
BRANCH VENT
DRY VENT
WET VENT
a horizontal vent pipe connecting from a branch of the drainage system to a vent stack or stack vent
BACKVENT PIPE
UNIT VENT
BRANCH VENT
DRY VENT
WET VENT
a vent that does not carry water or water borne waste
BACKVENT PIPE
UNIT VENT
BRANCH VENT
DRY VENT
WET VENT
portion of a vent pipe through which liquid waste flow
BACKVENT PIPE
UNIT VENT
BRANCH VENT
DRY VENT
WET VENT
a pipe or shaft serving to convey foul air from a plumbing fixture or a room to the outer air
LOCAL VENT
CIRCUIT VENT
RELIEF VENT
LOOP OR CIRCUIT VENT
YOKE VENT
group vent from in front of the last fixture/connects to vent stack (LOOP VENT)
LOCAL VENT
CIRCUIT VENT
RELIEF VENT
LOOP OR CIRCUIT VENT
YOKE VENT
acts as auxiliary vent (“yoke vent”)
LOCAL VENT
CIRCUIT VENT
RELIEF VENT
LOOP OR CIRCUIT VENT
YOKE VENT
(extension is usually vertical immediately beyond its connection to the soil or waste pipe); connected to the stack vent
LOCAL VENT
CIRCUIT VENT
RELIEF VENT
LOOP OR CIRCUIT VENT
YOKE VENT
pipe connecting upward from a soil or waste stack below the floor and below horizontal connection to a adjacent vent stack
LOCAL VENT
CIRCUIT VENT
RELIEF VENT
LOOP OR CIRCUIT VENT
YOKE VENT
Minimum requirement for a waste and vent pipe installation: Installation consisting of a WC, LAV, SINK, a BT on first floor, and LT in basement with a drain, soil waste, and vent pipe arrangement
Principle 1
Principle 2
Principle 3
Principle 4
Principle 5
Maximum requirements: Layout of a drain, soil waste, and vent pipe installation
Principle 1
Principle 2
Principle 3
Principle 4
Principle 5
Individual Ventilation: Layout consisting of a WC, LAV, & Sink on first floor; WC, LAV & BT on 2nd floor; LT located in basement
Principle 1
Principle 2
Principle 3
Principle 4
Principle 5
Plumbing for a duplex: WC, LAV, (2) LT in basement, toilet on 1st and 2nd Flr - WC, LAV and BT are installed. Sink provided in each kitchen
Principle 1
Principle 2
Principle 3
Principle 4
Principle 5
Typical installation of a soil and waste stack in a 3 storey apartment building: wet ventilation of the bathroom groups is employed
Principle 1
Principle 2
Principle 3
Principle 4
Principle 5
Fixtures discharging into sanitary crosses wasted and vented: Installation consists of a soil pipe serving 4 complete bathrooms and a sink waste on which 4 sinks are installed for two-storey apartment buildings
Principle 6
Principle 7
Principle 8
Principle 9
Principle 10
Unit waste and vent applied to bathroom fixture groups on opposite sides of a partition typical of hotel and apartment house layouts
Principle 6
Principle 7
Principle 8
Principle 9
Principle 10
Installation common to multi-storey apartment and hotel buildings
Principle 6
Principle 7
Principle 8
Principle 9
Principle 10
Waste and vent pipe installation for small toilet room on each floor of a 2-storey industrial building; lower floor men’s toilet room (5 WCs 2 LAVs, 2 URs located on common partition; upper floor – ladies’ toilet room (5 WCs, 4 LAVs) located on one partition
Principle 6
Principle 7
Principle 8
Principle 9
Principle 10
Common to buildings of larger design: Women’s toilet room (2nd Flr), Men’s toilet room (1st Flr) fixtures located on opposite partitions
Principle 6
Principle 7
Principle 8
Principle 9
Principle 10