wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Interviewee Exam for RC District Cooling Plant Project

Total questions: 25

Worksheet time: 39mins

Name
Class
Date
1.

Ongoing expenses incurred from the normal day-to-day of running a business?

a)

Contingency Cost

b)

Operating Cost

c)

Overhead Cost

d)

All of the given

2.

Refers to the ongoing costs to operate a business but excludes the direct costs associated with creating a product or service

a)

Contingency Cost

b)

Operating Cost

c)

Overhead Cost

d)

All of the given

3.

Refers to the application of processes, methods, skills, knowledge and experience to achieve specific project.

a)

Project Management

b)

Project Execution

c)

Construction Management

d)

Construction Execution

4.

A business methodology that aims to improve processes, reduce waste and errors, and increase customer satisfaction throughout an organization.

a)

Agile

b)

Scrum

c)

Six Sigma

d)

Lean

5.

Promotes maximizing customer value, while minimizing waste. It aims to create more value for the customer by using fewer resources.

a)

Agile

b)

Scrum

c)

Six Sigma

d)

Lean

6.

It is a tool utilized to measure the performance and compliance of the Plant or Project from the standard established for a project?

a)

Performance Evaluation

b)

COP, Coefficient of Performance

c)

KPI, key Performance Indicator

d)

All of the given

7.

If the Operation Cost is Higher the value compared to the Income and profit of the business, then your business operation is in what condition?

a)

not enough information

b)

Project is Gaining

c)

Project is Break even

d)

Project is Loosing

8.

Refers to the total amount of income generated by the sale of goods or services related to the company's primary operations.

a)

Revenue

b)

Project Cost

c)

Operation Cost

d)

Contingency Cost

9.

In Project Management what is the meaning of PERT CPM?

a)

Programme Evaluation & Review Technique / Critical Path Method

b)

Progress Evaluation & Research Techniques / Critical Project Method

c)

Programme Evaluation & Research Techniques / Critical Project Method

d)

None of the given

10.

What are the Main Process Equipment of District Cooling Plant?

a)

All of the given

b)

Air-cooled Chiller, Process Pumps (CHWP, SCHWP, CWP), Air Separator, Expansion Tank, Cooling Tower

c)

Water-Cooled Chiller, Thermal Energy Storage, Cooling Tower

d)

Water-Cooled Chiller, Process Pumps (CHWP, SCHWP, CWP) and Cooling Tower

11.

How to measure the efficiency and performance of your Cooling Tower?

a)

Water Quality and Chemistry

b)

Cycle of Concentration

c)

Drift loss and evaporation

d)

None of the given

12.

What is Thermal Energy Storage and its function in the Chilled Water Loop?

a)

Serves as Make-up system to Close Loop

b)

It handles Thermal Expansion as water heats up.

c)

Serves as Storage Tank during Low Demad and Supplies Chilled Water to SCHWP during High Demand.

d)

All of the given

13.

In Upstream-Downstream Chiller Set-up Principle, what Chiller will operate first during start-up or Low Demand and Low CHW Return Temperature?

a)

Upstream Chiller will start first

b)

Downstream Chiller will start first

c)

Both Upstream and Downstream Chiller will start

d)

All of the given

14.

What Process Pump is responsible for the Flow of your Chilled Water Supply and the demand requirement of your Energy Transfer Stations?

a)

Primary Pump

b)

Secondary Pump

c)

Condenser Water Pump

d)

ETS Secondary Pump

15.

For Energy Transfer Stations, what is the specific Valve that controls the flow of CHW Primary Loop in order to sustain the temperature requirement of the CHW Secondary Loop?

a)

MOV, Motorized Butterfly Valve

b)

MOD, Modulating Motorized Butterfly Valve

c)

PICV, Pressure Independent Control Valve

d)

None of the given

16.

It is the term use in KPI for the Total Production of Chilled Water in Tonn-Hour (TRH) over the Total Consumption of Energy in Kilowatt-Hour (KWH)?

a)

DCP & ETS Demand Philosophy

b)

DCP Philosophy

c)

COP, Coefficient of Performance

d)

ER, Energy Ratio

17.

How much will be the required flow of the Primary Pump for the 6,000 TR Capacity of your Chiller where Delta T is equal to 9 deg.C. (Q = m X Cp X ΔT) or (Q = ΔT X V X 1000/3024)

a)

568 l/s or 2,044.8 m3/h

b)

592 l/s or 2,131.2 m3/h

c)

947 l/s or 3,409.2 m3/h

d)

500 l/s or 1,800 m3/h

18.

How much frequency should your SCHWP will operate if the ETS demand is equal to 300 l/s?

a)

40 Hz

b)

35 Hz

c)

30 Hz

d)

25 Hz

19.

If your Water-Cooled Chiller Condenser Approach parameter reaches to "0-2" Limit Range, it is a call-out for?

a)

Cooling Tower Fan Speed Adjustment

b)

Condenser Additional Flow Requirement

c)

Chiller Change Oil Maintenance

d)

Condenser Tube Cleaning / Maintenance

20.

In Capacitor Terminal Connection shown on the picture below what is the meaning of "C" ?

a)

Charged

b)

Current

c)

Common

d)

Compressor

21.

What is NPSH(a) means and what is the importance on your pump?

a)

New Pressure Suction Header, imprtant to maintain the good flow on your pump.

b)

New Pump Section Head, for better header pressure of the pump.

c)

Net Positive Suction Head, it is important to avoid the risk of cavitation in the system

d)

None of the given

22.

What is Tribology and why we need this in our mechanical equipment?

a)

The study of Life Span of the Mechanical Parts in order to forecast when Preventive Maintenace will perform

b)

The study of Mechanical Equipment performace to maximize the efficiency

c)

The Study of Wear, Friction and Lubrication to improve the performance of mechanical equipment

d)

The Study of Origin of the equioment to maintain properly

23.

What is the indication that your pump is experiencing Cavitation?

a)

Suction Pressure is erratic and wheezing sound will be heard on your impeller side.

b)

Discharge Pressure is low and pump vibration excessive.

c)

Differential Pressure is high and but less flow

d)

All of the given

24.

What is the Purpose of Capacitor in HVAC System?

a)

Protection against unbalance Voltage

b)

To protect compressor from Low/High Pressure

c)

To protect your compressor from Over Current

d)

To store electrons to provide start-up energy for your Compressor & Fan Motor

25.

What is the importance of Cathodic Protection in our Thermal Energy Storage Tanks, Water Tanks and Pipelines.

a)

Prevent form lightning and other groundings

b)

Earth groundings of all tanks

c)

Additional Stability for the Structure of the Tanks

d)

Effective methods for preventing corrosion on a metal surfaces