Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

9189PH3ELECTPPT6

Total questions: 39

Worksheet time: 20mins

Name
Class
Date
1.

Who must carry out any electrical work due to the inherent danger it poses?

a)

Any individual

b)

Only competent operatives

c)

Only homeowners

d)

Any plumber

2.

What are the restricted areas for electrical equipment installation known as?

a)

Circuits

b)

Zones

c)

Sections

d)

Regions

3.

According to BS 7671 18th edition, which zone is the space under the bath if it is accessible without the use of a tool?

a)

Zone 0

b)

Zone 1

c)

Zone 2

d)

Outside the zones

4.

What should be followed regarding the use of individual equipment within the specified zones?

a)

Local government regulations

b)

Manufacturers' instructions

c)

Personal judgment

d)

General guidelines

5.

Where should a boiler be installed in a bathroom according to general rules?

a)

Inside zones 0, 1, and 2

b)

Outside zones 0, 1, and 2

c)

Directly above the bath

d)

Next to the basin

6.

Where should the fused spur feeding a boiler be located if the boiler is installed in a bathroom?

a)

Inside the bathroom

b)

Outside the bathroom

c)

Under the bath

d)

Next to the shower

7.

What is a requirement for the placement of electrical equipment in a bathroom to ensure safety?

a)

It can be touched while using the bath or basin

b)

It should be in direct contact with water

c)

It cannot be touched while also touching water within the bath, shower, basin, or any other water source

d)

It should be installed without a protective cover

8.

How should electrical equipment ideally be protected in a bathroom?

a)

By placing it in an open shelf

b)

By placing it in a closable cupboard

c)

By covering it with a waterproof cloth

d)

By installing it near a heat source

9.

What additional protection should all equipment installed in a bathroom have?

a)

An RCCB

b)

An RCD

c)

A fuse

d)

A circuit breaker

10.

Where can showers be fitted according to the manufacturer's instructions?

a)

Only outside zones 1 and 2

b)

Within zones 1 and 2

c)

Only in zone 1

d)

Anywhere in the bathroom without restrictions

11.

What must showers be protected by?

a)

A waterproof cover

b)

An RCD

c)

A dedicated water supply

d)

An isolator switch

12.

Where must the isolator for a Jacuzzi bath pump be positioned?

a)

Inside the bathroom

b)

Under the bath

c)

Outside the bathroom

d)

Within zone 2

13.

Extractor fans suitable for zone 1 must be checked for what?

a)

Energy efficiency

b)

Noise levels

c)

Suitability and protection by an RCD

d)

Color and design

14.

What is the purpose of a programmer in individual heating and hot water circuits within a dwelling?

a)

To cut off the power supply

b)

To control individual heating and hot water circuits

c)

To monitor the temperature of the water

d)

To provide insulation to the heating systems

15.

What is the function of the double pole switch?

a)

To isolate live and neutral

b)

To disconnect the power supply

c)

To control the temperature settings

d)

To act as a fuse for the heating system

16.

What type of valve can be operated by a room thermostat within a heating system?

a)

A one-port valve

b)

A two- or three-port valve

c)

A pressure relief valve

d)

A butterfly valve

17.

In what type of plan systems can a room thermostat operate a valve?

a)

A- and B-plan systems

b)

S- and T-plan systems

c)

S- or Y-plan systems

d)

X- and Z-plan systems

18.

How do wireless room thermostats operate?

a)

By using a wired connection to the sensor

b)

By using thermistors and an RF signal between the sensor and the remote receiver

c)

By using Bluetooth technology only

d)

By using infrared signals

19.

What is the main advantage of using wireless room thermostats mentioned in the text?

a)

They are more accurate than wired thermostats

b)

They can be controlled via a smartphone

c)

They remove the need for unsightly cables

d)

They use less energy

20.

What is positioned at the back of a cylinder thermostat against the surface of a cylinder?

a)

A calibrated bimetallic strip

b)

A micro-switch

c)

A set point adjustment screw

d)

A fixed point

21.

What happens when the cylinder thermostat senses the pre-set temperature?

a)

It increases the electrical supply to the DHW zone valve.

b)

It turns off the electrical supply to the DHW zone valve.

c)

It breaks the bimetallic strip.

d)

It activates the micro-switch.

22.

What is the function of the set point adjustment screw in a cylinder thermostat?

a)

To fix the thermostat to the cylinder

b)

To adjust the sensitivity of the micro-switch

c)

To calibrate the bimetallic strip

d)

To set the temperature at which the thermostat will turn off the electrical supply

23.

What is provided with an immersion heater for temperature control according to the learning material?

a)

A single-tier temperature control

b)

A two-tier temperature control

c)

A manually adjustable temperature control only

d)

A digital temperature control

24.

What is the size of the typical Honeywell two-port zone valve shown in the learning material?

a)

15mm

b)

22mm

c)

30mm

d)

25mm

25.

What happens when the Honeywell two-port zone valve fully opens?

a)

The microswitch is disconnected.

b)

The valve closes automatically.

c)

The microswitch closes to turn on appliances as necessary.

d)

The motor stops operating.

26.

What is one of the functions of a thermistor in a combination boiler or multipoint water heater?

a)

It generates heat to warm the water.

b)

It measures water flow rate.

c)

It accurately measures temperature and helps to control the operation.

d)

It provides electrical insulation.

27.

How does an appliance use the thermistor to regulate temperature?

a)

By reading the resistance of the thermistor and adjusting the water pressure.

b)

By reading the resistance of the thermistor and adjusting the temperature accordingly.

c)

By using the thermistor to increase the electrical current.

d)

By using the thermistor to decrease the water flow.

28.

What is the first step in the basic sequence of operation for a gas fired, fanned-flue boiler according to the diagram?

a)

Boiler thermostat calling for heat

b)

Fan operates

c)

Signal to boiler control panel from zone valve

d)

Pressure switch senses pressure change

29.

What happens immediately after the pressure switch senses a pressure change in the sequence of operation for a gas fired, fanned-flue boiler?

a)

Gas valve solenoid opens

b)

Ignition process begins via control panel

c)

Main burner ignites

d)

Boiler thermostat calling for heat

30.

What is the final step in the basic sequence of operation for a gas fired, fanned-flue boiler as shown in the diagram?

a)

Flame verified

b)

Gas valve solenoid opens

c)

Main burner ignites

d)

Fan operates

31.

What is the purpose of flame rectification in boiler designs?

a)

To cool down the boiler

b)

To rectify electrical faults in the boiler

c)

To supervise the flame as a safety measure

d)

To increase the efficiency of fuel combustion

32.

How does flame rectification work?

a)

By using water as a conductor to generate electricity

b)

By utilising a flame as a conductor and passing a current through it

c)

By converting chemical energy directly into electrical energy

d)

By using a mechanical switch to detect the presence of a flame

33.

What happens when there is no flame in the boiler system?

a)

The boiler will continue to operate normally

b)

The ignition sequence is triggered repeatedly

c)

The control box shuts down the system

d)

No ignition sequence can begin

34.

How does the ignition controller verify the presence of the flame at the pilot?

a)

By sending a signal to open the gas valve solenoid.

b)

By calling for heat.

c)

By using flame rectification.

d)

By terminating the signal to the gas valve.

35.

What happens when the room thermostat is satisfied?

a)

The ignition controller sends a spark to the electrode.

b)

The signal to the gas valve is terminated and the flame goes out.

c)

The gas valve solenoid opens.

d)

The ignition controller verifies the presence of the flame.

36.

What is the role of the gas valve solenoid in the boiler system?

a)

It verifies the presence of the flame at the pilot.

b)

It sends a spark to the electrode to ignite the gas.

c)

It opens to allow gas to flow when the ignition controller sends the signal.

d)

It calls for heat when the thermostat is activated.

37.

What is the purpose of an air pressure switch in a boiler system?

a)

To regulate the temperature of the water

b)

To ensure that the fan is operating within the boiler

c)

To control the flow of gas to the burners

d)

To monitor the level of water in the boiler

38.

What type of plan is depicted in the wiring schematics for heating and hot water in the image?

a)

Y-plan

b)

S-plan

c)

W-plan

d)

X-plan

39.

What is the frequency of the power supply shown in the wiring schematics?

a)

60Hz

b)

50Hz

c)

40Hz

d)

70Hz