wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

L3 YR2 Revision 1 (Cold 1)

Total questions: 78

Worksheet time: 39mins

Name
Class
Date
1.

The main advantage of using a sectional storage cistern is that it can be ...

a)

Lightweight

b)

No supports required

c)

Tailored to fit any space

d)

Installed in a basement

2.

The warning pipe of a large CWSC must discharge

a)

Into a rainwater collection header

b)

So as not to create a nuisance

c)

In a noticeable place

d)

Directly into a gutter

3.

Which of the following would NOT be an action taken by a plumber to reduce water hammer

a)

Fit equilibrium float operated valves

b)

Fit flow restricters in the supply to float operated valves

c)

Reduce flow by turning down supply through consumers stop tap

d)

Ensure pipework is adequately secured

4.

Which one of the following would be most appropriate to a potential client when tendering for work.

a)

Bill of Quantities and sketch

b)

Quotation and scale drawing

c)

Specification and Bill of Quantities

d)

Specification and scale drawing

5.

When undertaking fault diagnosis work on cold water system component, which one of the following sources of information should be considered first?

a)

British standards

b)

Codes of practice

c)

Manufacturers data

d)

Customer

6.

What procedure should be used to verify the correct operation of a cold water storage cistern float switch?

a)

Check amps at pumps

b)

Electrically bypass the float switch

c)

Manually operate the float arm

d)

Check voltage at switch

7.

Which one of the following components must also be removed when replacing the packing gland on a long neck pillar tap?

a)

Tap head

b)

Circlip

c)

Top hat washer

d)

Jumper plate

8.

The parts of a verifiable check valve which are used to help diagnose any faults which may exist on the valve are:

a)

D.O.C.

b)

Test points

c)

Check valve

d)

Olive

9.

An accumulation of white powder on the surface of a brass fitting, is most likely to be an indication of:

a)

Blue water corrosion

b)

Chemical corrosion

c)

Electrolytic action

d)

PH water

10.

Which one of the following items of information should be contained on a cold water commissioning record?

a)

Discharge flow rates

b)

Air temperatures

c)

Length of Secondary return

d)

Number of workers

11.

The installation of an additional bathroom to a premise is notifiable under the ...

a)

Codes of practice

b)

British standards

c)

Building Regulations

d)

Gas safe register

12.

When the temperature of the cold water from a distribution pipe exceeds 25 degrees, what action should be taken?

a)

Install a water cooler

b)

Install a water filter

c)

Check and improve the insulation

d)

Check all air gaps

13.

A pressure gauge attached to cold water pipework measures what pressure?

a)

Flow rates

b)

Hydraulic lift

c)

Working pressure

d)

Standing pressure

14.

According to the Water Regulations, which one of the following cold water systems needs disinfecting after alterations to cold water pipework?

a)

Private flat

b)

Commercial buildings

c)

Domestic dwelling

d)

Care homes

15.

If plastic pipes are subjected to test pressures that are designed for metallic pipes there is an increased risk that the pipe material will become...

a)

Distorted bores

b)

Stretched radially

c)

porous

d)

Stressed

16.

For maintenance purposes the end user of a cold water system should be made aware of the position of the:

a)

Emergency shut off

b)

Service valve on W.C

c)

RPZ valve

d)

Pressure relief valve

17.

Which one of the following is responsible for enforcing the Private Water Supplies Regulations?

a)

Hetas

b)

Water regulations advisory scheme

c)

Drinking Water Inspectorate

d)

Building control

18.

In which situation would a type CA disconnector most likely to be used?

a)

To provide protection when a flushing valve is fitted

b)

To make a mains connection into a recycled water system

c)

As a protection device When making a permanent mains connection to a heating system in a commercial property

d)

as protection from a photographic facility

19.

Which of the following would be a preferred method for fault diagnosis on a verifiable backflow protection device?

a)

Simulating reduced pressure upstream

b)

Isolating and opening a tap

c)

Increase pressure downstream

d)

Simulating reduced pressure downstream

20.

Break cisterns with a stored capacity of between 1000 and 5000 litres must be fitted with:

a)

Overflow pipe

b)

Overflow pipe and warning pipe

c)

Warning pipe only

d)

A float switch

21.

A Competent Persons Scheme allows competent plumbers to sign off their own work which means:

a)

The CIPHE do not have to visit and verify their jobs

b)

The LABC do not have have to visit and verify their jobs

c)

The CITB do not have to visit and verify their jobs

d)

The JIBMES do not have to visit and verify their jobs

22.

Direct boosting systems are installed:

a)

Wherever mains pressure is below 1 bar

b)

Where permission has been granted by the customer

c)

Where permission has been granted by the water undertaker

d)

Where permission has been granted by the local undertaker

23.

The capacity of a break cistern needs careful consideration and will depend on the total water storage requirements and the cisterns location but it should not be less than ???? of the pumps maximum output.

a)

15%

b)

25%

c)

45%

d)

50%

24.

A water level switch positioned in a break cistern should automatically switch off the pumps if the water level drops to within ????mm of the suction connection near the bottom of the break cistern.

a)

125mm

b)

225mm

c)

325mm

d)

50mm

25.

Which one of the following is NOT a type of aquifer?

a)

Unconfined aquifer

b)

Confined aquifer

c)

Parched aquifer

d)

Perched aquifer

26.

Reverse osmosis works by

a)

Forcing the water under pressure through a non permeable membrane

b)

Forcing the water under pressure through a muslin filter

c)

Allowing the schmutzdecke layer to form

d)

Forcing the water under pressure through a semi permeable membrane

27.

Air pressure in an accumulator can be adjusted through the

a)

schrader valve

b)

venturi

c)

globe valve

d)

multi functional valve

28.

Central heating water would be a fluid category

a)

1

b)

2

c)

3

d)

4

e)

5

29.

What is a non concussive tap?

a)

self sealing

b)

self opening

c)

self closing

d)

self cleaning

30.

To make a hot connection into a cylinder a proprietary fitting can be used. Which of the following is NOT a method?

a)

Barnsley flange

b)

Warix flange

c)

Surrey flange

d)

Essex flange

31.

A type AUK 2 back-flow prevention device is MOST likely to be used on:

a)

Washing machine

b)

Wash basin tap outlet

c)

Kitchen sink tap outlet

d)

In a W.C. arrangement

32.

Which one of the following components is designed to absorb hydraulic pressure when water is suddenly arrested?

a)

Temperature relief valve

b)

In-line strainer

c)

Shock arrestor

d)

Pressure relief valve

33.

The flexible hose of a combination bath and shower MUST pass through a clip to prevent the head coming into contact with:

a)

Tap controls

b)

People bathing

c)

Nearby saddle bracket

d)

Standing bath water

34.

Which one of the following would provide design information on a proposed cold water installation?

a)

Tender drawings

b)

Bill of Quantities

c)

Specification

d)

Architects instruction

35.

Externally fitted plastic break tanks MUST be protected against ...

a)

Contamination

b)

Potable water

c)

Air ingress

d)

Wholesome water

36.

A cold water booster pump is most likely to be installed in a single family dwelling supplying water to all outlets and...

a)

A high flow supply

b)

Thermal storage heater

c)

A low flow supply

d)

A vented cylinder

37.

Ultraviolet treatment units are used to...

a)

Filter large particles

b)

Help suspend any solids

c)

Filter coarse microbiological particles

d)

Kill microbiological matter

38.

What type of back-flow prevention is required to be applied at the point of entry of a single supply to a multiple occupation property

a)

A point of entry device

b)

Zone protection device

c)

Point of use device

d)

Zone of usage device

39.

Under the Water Regulations water in fluid risk category 2 is described as...

a)

Slightly toxic

b)

Aesthetically impaired

c)

Wholesome

d)

Potentially hazardous

40.

Which component may need to be installed in mains fed cold water pipework near to a lever operated mixer tap fitted with a single check valve?

a)

Temperature relief valve

b)

Shock arrestor

c)

Pressure relief valve

d)

Pressure reducing valve

41.

In which of the following situations would a single check valve be used?

a)

To provide protection when a mains flushing valve is fitted

b)

To make a mains connection into a commercial heating system

c)

As a protection device when a permeable hose is used

d)

As a method of preventing back pressure in an unvented system

42.

Which of the following is used to take accurate measurements from a site for design calculations?

a)

Tape measure

b)

Theodolite

c)

Laser rule

d)

Scale rule

43.

What type of information relating to system operation are end users best placed to provide?

a)

Flow rates

b)

Immediate history

c)

Hot flow rate

d)

Service plan

44.

The parts of a verifiable check valve which are used to help diagnose any faults which may exist on the valve are ...

a)

D.O.C.

b)

Valve springs

c)

Test points

d)

Union connector

45.

What is the main problem with installing single check valves in mains pressure cold water pipework that can be subject to variance in surrounding ambient air temperature?

a)

The overheating of the hot water pipework

b)

A significant reduction in system operating pressure

c)

The overall reduction in system operating pressure

d)

A significant increase in available system pressure that can lead to damage of components

46.

Which of the following identifies the responsibility of the user of a water fitting under Regulation 3 of the Water Regulations?

a)

That there is no insulation in any heated area

b)

That there is no undue water pressure effects

c)

That there is no adequately supported pipework

d)

That there is no undue consumption of water

47.

Which of the following requires notification to Building Control under the requirements of Building Regulations?

a)

The replacement of the feed and expansion tank

b)

The installation of a wholesome supply

c)

The installation of a double check valve

d)

The replacement of a water conditioner

48.

On a borehole installation which of the following MUST be installed upstream of an accumulator?

a)

Check valve

b)

Anti-vac valve

c)

Temperature relief valve

d)

PRV

49.

In which of the following situations would a DB pipe interrupter with atmospheric vent and moving element most likely be used?

a)

An integral device within a close coupled cistern

b)

To make a mains connection to a rainwater harvesting

c)

As a protection device when a permeable hose system is used

d)

To provide protection when a mains flushing valve is fitted

50.

Which of the following would be an advantage of installing an infrared-operated tap?

a)

Easy to operate

b)

They stop the spread of germs and bacteria

c)

They can help with water conservation

d)

They can prevent injury by scalding

e)

All the above

51.

Shower pumps have to be carefully selected, which of the following should be used where the shower head is 0.5m above the cistern water level?

a)

Positive head pump

b)

Negative head pump

c)

Sump pump

d)

Submersible pump

52.

Hydraulic shock can cause water hammer with the quick closing of a valve, how does a shock arrestor eliminate the problem?

a)

MCB absorbs the shock wave which is dissipated

b)

TMV absorbs the shock wave which is dissipated

c)

Check valve absorbs the shock wave which is dissipated

d)

Piston absorbs the shock wave which is dissipated

53.

A loading unit is equivalent to

a)

1 l/s

b)

0.5 l/s

c)

0.1 l/s

d)

0.9 l/s

54.

What is a solenoid valve?

a)

An electro-magnet valve used to limit the flow of water

b)

An electro-magnet valve used to control the flow of water into a cistern

c)

A limiting valve used to prevent water running into a cistern

d)

A component found in an accumulator

55.

Disinfection of private water supplies is ideally done using which of the following methods?

a)

Ultraviolet irradiation

b)

Chlorine

c)

Chloride

d)

Ultrablue irradiation

56.

Which mechanical backflow prevention device is also known as a type BA device?

a)

Thermostatic valve

b)

TRV valve

c)

RPZ valve

d)

TMV valve

57.

To whom should notification of an installation and commissioning of cold water systems be given?

a)

Both water undertaker and the local building control office

b)

Water undertaker

c)

Building control

d)

Architect

58.

Which set of regulations regulates boreholes and wells?

a)

Part G Building regulations

b)

The Water (Water fittings) Regulations 1999

c)

The private Water Supply regulations

d)

Part L Building Regulations

59.

An RPZ valve should be installed with

a)

an isolating valve upstream of the RPZ valve

b)

an isolating valve downstream of the RPZ valve

c)

an isolating valve both upstream and downstream of the RPZ valve

d)

no isolating valves

60.

In which one of the following fluid categories does the domestic water from a wash hand basin fall?

a)

Category 1

b)

Category 2

c)

Category 3

d)

Category 4

61.

Under Regulation 5 of the Water Regulations, the water undertaker must be informed when which one of the following operations is carried out?

a)

Installation of a pump drawing more than 12 litres per minute

b)

Installation of a bidet without an ascending spray or flexible hose

c)

Installation of a bath with a capacity of less than 230 litres

d)

Installation of an RPZ valve to protect against a category 2 fluid

62.

What is the component labelled A in the diagram

a)

Expansion cistern

b)

Break cistern

c)

Duplicate pumps

d)

Circulating pumps

63.

The type of non-mechanical backflow prevention used on a domestic wash hand basin is known as

a)

AUK 1

b)

AUK 2

c)

AUK 3

d)

AUK 4

64.

Which of the following items of legislation covers the requirements for the hydraulic testing of cold water pipe lines?

a)

Water Byelaws (England 2004)

b)

British Standards 5449

c)

Water Supply (Water Fittings) Regulations 1999

d)

Building Regulations Part G (P in Northern Ireland)

65.

Which one of the following mechanical backflow prevention devices would be used when installing a replacement hose union bib tap?

a)

BA

b)

HUK1

c)

HC

d)

HA

66.

Which of the following types of air gap provides suitable backflow protection for the taps in a wash hand basin installed in a hospital?

a)

AB air gap

b)

AUK 1 air gap

c)

AUK 2 air gap

d)

AUK 3 air gap

67.

Service valves should be installed in which one of the following locations?

a)

On the cold feed to the primary circuit

b)

On the cold feed pipe from the cold water storage cistern

c)

Immediately after the internal stop valve

d)

Immediately after the external stop valve

68.

Metallic cold water systems should be capable of withstanding an internal pressure of:

a)

the maximum potential operating pressure

b)

1.5 times the maximum potential operating pressure

c)

2 times the maximum potential operating pressure

d)

3 times the maximum potential operating pressure

69.

When preparing to commission a boosted cold water system in an occupied block of flats, which one of the following should be advised of the work in the first instance?

a)

Water Supplier

b)

Occupants

c)

WRAS

d)

Building Control

70.

The performance specification of an RPZ valve would be found in which one of the following?

a)

WRAS Water fittings and Materials Guide

b)

BS6700

c)

Manufacturer’s instructions

d)

Water regulations guide

71.

For an RPZ valve to meet its product specification it should be

a)

provided with a drain pipe via a tundish

b)

installed without isolation valves

c)

sited close to an electrical supply

d)

only installed in a very low pressure supply

72.

What would the colour banding on the pipework in the picture indicate?

a)

Recycled water supply pipe

b)

Cold water supply pipe

c)

Fire fighting water supply pipe

d)

Private water supply pipe

73.

When flushing a domestic cold water system, which one of the following types of liquid should be used?

a)

Concentrated disinfectant

b)

Drinking water

c)

Diluted disinfectant.

d)

Recycled water

74.

Which of the following items of information should be recorded on the commissioning record for a boosted cold water system in a block of flats?

a)

Details of the installation sequence and programme

b)

Results of the risk assessments carried out

c)

COSHH assessment results of materials used

d)

Component performance details against the specifications

75.

When handing over a newly commissioned domestic cold water system, the customer should be advised

a)

only to drink water from the hot tap if boiled first

b)

which tap outlets are suitable for drinking water

c)

that the water feed and expansion cistern is wholesome water

d)

harvested rainwater is suitable for cooking if boiled first

76.

Pressure testing of underground service pipe work should take place:

a)

before back filling has started

b)

after approval from the Clerk of Works

c)

after back filling has been completed

d)

after approval from the Water Supplier

77.

Which one of the following is considered the best way to present design information?

a)

Rough sketches

b)

Spreadsheets

c)

Scale drawings

d)

Not to scale drawings

78.

Pipework made from which one of the following materials is susceptible to blue water corrosion?

a)

Plastic

b)

Low carbon steel

c)

Stainless steel

d)

Copper