GMJ 6035 electrical quiz NEW

Total questions: 52

Worksheet time: 26mins

Name
Class
Date
1.

Which of the following documents should be referred to for specific wiring details of domestic heating controls?

a)

Manufactures Instructions

b)

Building Regulations

c)

Wiring Regulations

d)

User Instructions

2.

Which one of the following is the most likely supply voltage type and rating used for central heating circulating pump?

a)

220 V a.c.

b)

110 V d.c.

c)

230 V a.c.

d)

230 V d.c.

3.

Which one of the following voltages would be found on a low voltage central heating wiring system?

a)

24 V a.c.

b)

24 V d.c.

c)

12 V d.c.

d)

110 V a.c.

4.

What type of domestic electrical circuit is shown in the following diagram?

a)

Spur Circuit

b)

Lighting Circuit

c)

Radial Circuit

d)

Ring Main Circuit

5.

Which one of the following earthing arrangements uses and installation earth electrode as part of the fault path?

a)

TN-C

b)

TN-C-S

c)

TT

d)

TN-S

6.

Which one of the following conductors connects an installation's Main Earthing Terminal to the incoming metallic Water Supply Service Pipe?

a)

Circuit Protective Conductor

b)

High Integrity Protective Conductor

c)

Main Protective Bonding Conductor

d)

Supplementary Bonding Conductor

7.

Which one of the following conductors would normally connect two water pipes together within a bathroom location?

a)

Circuit Protective Conductor

b)

High Integrity Protective Conductor

c)

Main Protective Bonding Conductor

d)

Supplementary Bonding Conductor

8.

Which one of the following protective devices operates under earth fault conditions only?

a)

RCD

b)

RCBO

c)

Circuit breaker

d)

HBC Fuse

9.

Identify the protective device in the image which operates when the system is overloaded?

a)

RCD

b)

RCBO

c)

Circuit breaker

d)

HBC Fuse

10.

Refer to the following list of cartridge fuses. Which one would be selected to provide overcurrent to the fused connection unit to a 230v domestic heating central heating control system with a total load of 600 Watts?

a)

3 A

b)

13 A

c)

16 A

d)

30 A

11.

Identify Component C in the image shown. This component would be used to distribute a single energy source to multiple final circuits within a domestic electrical installation?

a)

Customers consumer unit

b)

Suppliers energy meter

c)

Suppliers cut-out

d)

Consumers main earth terminal

12.

What type of electrical cable is shown in the image?

a)

Heat resisting PVC insulated sheathed 3 core flexible cable

b)

PVC insulated and sheathed this and earth flat wiring cable

c)

PVC insulated and sheathed 3 core and earth flat wiring cable

d)

Armoured SWA type 3 core cable

13.

Which one of the following protection methods applies when installing circuits using single-core cable?

a)

The cable must be directly buried in the wall

b)

The cables must be clipped to the surface

c)

The cables must be enclosed in conduit

d)

The cables must be protected by an RCD

14.

Which one of the following would most likely be the first to be damaged if the current in a cable exceeds its current carrying capacity?

a)

Cable core

b)

Cable Insulation

c)

Cable sheathing

d)

Cable Containment

15.

Which one of the following names the component shown in the image?

a)

Terminal Strip

b)

Temporary continuity bond

c)

Earth bonding clamp

d)

Pillar terminal fixing

16.

Which one of the following is shown in the image?

a)

PVC insulated multi core flexible cable

b)

PVC insulated and sheathed twin and earth cable

c)

PVC insulated and sheathed 3 core and earth cable

d)

Heat resisting PVC insulated 3 core flexible cable

17.

Which one of the following states the recommended method used to secure a circuit breaker in the off position?

a)

Electrician working warning notice

b)

Locking device with unique key

c)

Removal of the circuit breaker

d)

Electrical insulation tape

18.

Which one of the following is shown in the image?

a)

Earthing bonding clamp

b)

PVC Insulated earth cable

c)

Voltage indicator

d)

Magnetic field indicator

19.

A circuit breaker located within a consumer control unit controlling a shower circuit requires replacement. Which one of the following states the correct part of the installation for the carrying out of safe isolation?

a)

The consumer unit main switch

b)

The circuit breaker being replaced

c)

At the local shower isolator switch

d)

At the suppliers main cut-out fuse

20.

A ring final circuit requires the addition of a fused connection unit for a boiler. Which of the following is the most suitable location to carry out safe isolation in order to carry out this work?

a)

The consumer unit main switch

b)

The circuit breaker for the circuit

c)

At the boiler time-clock/controller

d)

At the suppliers main cut-out fuse

21.

Which one of the following is the correct method of ensuring safety following safe isolation and locking off the circuit?

a)

Give a copy of the key to the client

b)

Keep the key beside the CCU

c)

Retain the unique key with you

d)

Keep the key in the lock

22.

Which one of the following is the correct order for the procedure?

a)

1, 3, 5, 2, 4, 1

b)

1, 5, 1, 4, 2, 3

c)

1, 4, 5, 2, 1, 3

d)

1, 2, 3, 4, 1, 5

23.

Which one of the following faults is most likely to cause electrocution?

a)

Short circuit

b)

Overload

c)

Loose connection

d)

Earth faults

24.

Which one of the following is the most likely fault if an appliance works intermittently?

a)

Loss of protective bonding

b)

Appliance fuse size over rated

c)

Loose connection in appliance plug

d)

Damaged insulation within the flexible cable

25.

Which one of the following would most likely cause an RCD to trip when an electric shower is switched on using local functional switch?

a)

A short circuit between live conductors in the shower final circuit

b)

A short circuit within the safety device included in the shower final circuit

c)

A fault between live conductors within the shower unit

d)

A fault between live and earth within the shower unit

26.

When wiring up a plug top, the connections should be made in a way to ensure that the cable is pulled with sufficient force to remove it from the plug?

a)

The earth connection would be the last to broken/earth

b)

The live connection would be the last to be broken/live

c)

The neutral connection would be the last to be broken/neutral

d)

All connections should break together/all together

27.

An intermittent fault exists in a hot water immersion heater. It appears that the cable has become brittle and the circuit keeps shorting out. What is the most likely cause of the fault?

a)

A non-heat resistant flex being used

b)

The wrong sized fuse installed

c)

The flex has incorrectly sized conductors

d)

the flex connections are loose

28.

Which one of the following is the most likely cause of brown discolouring around the front of the socket-outlet?

a)

Loose line connection within the plug of an appliance regularly used at socket

b)

Loose connection of the circuit neutral at the main neutral bar within the CCU

c)

Loose CPC within the plug of an appliance regularly used at the socket

d)

Loose CPC connection at the back of the socket-outlet which has discoloured

29.

Fault diagnosis reveals a serious fault in a domestic installation which could result in serious electric shock if not rectified. Which one of the following persons should be informed immediately in this situation?

a)

The health and safety executive

b)

The local building control Authority

c)

The owner/occupier of the property

d)

The institute of engineering technology

30.

Fault diagnosis is being undertaken in a building during non-working hours (when the building is unoccupied). A serious and life-threatening fault is discovered to the wiring of a circuit and rectification of the fault will require major works. Which one of the following actions would be the most appropriate in this situation?

a)

The circuit should remain un-touched until a suitable meeting with the client is arranged

b)

The circuit should be securely isolated until the client can be informed of the risk

c)

The circuit should be stripped out until an agreement to rewire it is made

d)

The section of the building concerned should be cordoned-off and notices posted

31.

Which one of the following is the most likely consequence if a loose neutral connection within a lighting circuit is not rectified?

a)

Increased energy bills

b)

Fire

c)

Electric shock

d)

Burns

32.

The item of equipment shown in the diagram is most likely to be used?

a)

As a quick method of connecting a live cable to an appliance if it is working following repair work

b)

For temporarily bridging the supply prior to the consumer unit and appliance where the MCB has tripped

c)

For connecting between the live and neutral on the ring main when carrying out a circuit polarity test

d)

As temporary earth continuity bonding whilst removing a section of metal pipe work

 

33.

Which one of the following is the reason for applying temporary continuity bonds to pipe work?

a)

They are applied after cutting a section of plastic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

b)

They are applied before cutting a section of plastic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

c)

They are applied after cutting a section of metallic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

d)

They are applied before cutting a section of metallic pipe to minimise the risk of electric shock should the pipe be carrying a residual fault current

34.

Which one of the following tools would be used to cut a copper conductor within a flexible cable to the correct length?

a)

Hacksaw

b)

Jigsaw

c)

Side cutters

d)

Craft knife

35.

Which one of the following types of connection is a commonly used within a joint box used in domestic wiring systems?

a)

Screw

b)

Compression

c)

Crimp

d)

Clamp

36.

Which one of the following tests would use a test voltage of 500 V d.c.?

a)

Continuity of protective conductors

b)

Continuity of ring final circuits

c)

Insulation resistance

d)

Polarity

37.

Which of the following devices is used to measure electrical current?

a)

An Ammeter

b)

An insulation resistance tester

c)

A digital manometer

d)

An approved voltage indicating device

38.

What is resistance measured in?

a)

Watts

b)

Volts

c)

Amps

d)

Ohms

39.

Which type of electrical test is carried out to confirm that line and neutral conductors are connected correctly and not crossed?

a)

Polarity test

b)

RCD test

c)

Insulation resistance test

d)

Earth continuity test

40.

Which one of the following colours connectors should be connected to the line terminal of a three-pin plug?

a)

Red

b)

Blue

c)

Brown

d)

Black

41.

When carrying out insulation resistance testing on a 230 V circuit the minimum acceptable value according to B” 7671 is

a)

0.5 Ω

b)

1.0 Ω

c)

0.5 MΩ

d)

1.0 MΩ

42.

When conducting a continuity test to ensure a radial circuit is earthed, the highest value of resistance would be measured at the

a)

Consumer unit

b)

Midpoint of the circuit

c)

Furthest point on the circuit

d)

Incoming water service pipe

43.

Which of the following is a reason for carrying out a polarity test? To ensure

a)

Conductors are correctly connected

b)

That no earth faults are present

c)

That no short circuits are present

d)

That the circuit is earthed

44.

What does R1 + R2 represents when measuring continuity

a)

The resistance of the line and neutral conductors

b)

The resistance of the circuit protective conductor

c)

The resistance of the line and circuit protective conductor

d)

The resistance of the water and gas protective bonding

45.

Which of the following would be the most appropriate cable for extending a domestic ring final circuit to provide a supply for new boiler?

a)

Flat profile twin and CPC sheathed

b)

Insulated wiring non-sheathed

c)

Single-core thermoplastic

d)

Multi-core flexible

46.

Which of the following protective devices would need to be replaced in the event of an overload?

a)

A cartridge fuse

b)

An RCD

c)

A circuit breaker

d)

An RCBO

47.

Which of the following is used to divide the electrical installation into circuits?

a)

Consumer unit

b)

Fused connection unit

c)

Ring main circuit

d)

Residual current device

48.

Which of the following arrangements uses the same conductor as the neutral and earth within the supply part of the system?

a)

TN-C-S

b)

TT

c)

TN-S

d)

IT

49.

When carrying out continuity testing which of the following describes the expected reading?

a)

High ohms

b)

Low Ohms

c)

High meg ohms

d)

Low meg ohms

50.

What would the correct course of action be if a dangerous electrical fault is discovered when working on a domestic boiler supply?

a)

Remove the suppliers cut out fuse

b)

Finish the current task then fix the fault

c)

Remove the dangerous circuit entirely

d)

Inform the customer of the need to isolate the supply

51.

Which of the following installation methods would be most appropriate for protection of flat profile twin and CPC cable on a wall?

a)

Clip it directly to the wall

b)

Install it in PVC conduit

c)

Install it in PVC trunking

d)

Install it in steel conduit

52.

When checking that the electrical supply is dead it is essential to check between

a)

Line and earth only

b)

Line and neutral only

c)

Line and neutral, line and earth only

d)

Line and neutral, Line and earth, neutral and earth