wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Tower Crane Test NCCCO

Total questions: 46

Worksheet time: 2hrs 18mins

Name
Class
Date
1.

1) which of the following OSHA regulations govern suspended personnel platforms:

a)

A OSHA 1910.180

b)

B OSHA 1926.1400

c)

C OSHA 1934.2 35

d)

D OSHA 1926.106

2.

2) according to ASME B30.3, the prohibited zone for power lines that are 60 kV is:

a)

A 10 feet

b)

B 12 feet

c)

C 15 feet

d)

D 20 feet

3.

3) according to ASME B30.3, load hoist rotation resistant wire rope has a design factor of:

a)

A .5 to 1

b)

B 3 to 1

c)

C 3.5 to 1

d)

D 5 to 1

4.

4) according to ASME B30.3, when lifting a suspended personnel platform the design factor for the rigging hardware is:

a)

A 2 to 1

b)

B 5 to 1

c)

C 7 to 1

d)

D 10 to 1

5.

5) according to ASME B30.3, load hoist ropes that are not rotation resistant must have a design factor of:

a)

A 2 .5 to 1

b)

B 3 to 1

c)

C 3.5 to 1

d)

D 5 to 1

6.

6) The OSHA construction standard for rigging equipment is:

a)

A 1925.550

b)

B 1910.180

c)

C 1926.251

d)

D 1910.18

7.

7) according to ASME B30.3, under whose recommendations should a preventative maintenance program be set up:

a)

A master mechanic

b)

B crane operator

c)

C company supervisor

d)

D Crane manufactur

8.

8) when using a cable or nylon spreaders it is important to remember:

a)

A the spreader angle does not affect tension

b)

B the lower the spreader angle the greater the tension

c)

C the higher the spreader angle the greater the tension

d)

D lower the spreader anger the lesser the tension

9.

9) according to OSHA, when testing a man basket how long must the test pick be maintained:

a)

A 2 minutes

b)

B 5 minutes

c)

C 10 minutes

d)

D 15 minutes

10.

10) according to ASME B30.3, what is the minimum pitch diameter for load load hoisting sheaves:

a)

A not less than 15 times the rope diameter

b)

B not less than 16 times the rope diameter

c)

C not less than 18 times the rope diameter

d)

D not less than 20 times the rope diameter

11.

11) according to ASME B30.3 what is the minimum pitch diameter for load block sheaves:

a)

A not less than 15 times of rope diameter

b)

B not lesson 16 times the rope diameter

c)

C not less than 18 times the rope diameter

d)

D not less than 20 times the rope diameter

12.

12) according to ASME B30.3, what is the minimum pitch diameter for boom hoist sheaves:

a)

A not less than 15 times the rope diameter

b)

B not less than 16 times the rope diameter

c)

C not lesson 18 times the rope diameter

d)

D not less than 20 times the rope diameter

13.

13) according to OSHA, when lifting personnel the cranes hook must be the type that:

a)

A can be closed and locked

b)

must be a standard hook without a latchB has a spring-loaded non-locking latch

c)

must be a swivel hookC no requirements for a safety latch

d)

must be a decorative hookD can be wired shut with # 9 wire

14.

14) according to OSHA, when working over water with the man basket are the people inside required to wear a belt/harness:

a)

A no harness or belt required

b)

B belt/harness always required

c)

C safety belt only required

d)

D harness only require

15.

15) according to ASME B30.3, when working near power lines where should caution stickers be installed:

a)

A on base of crane and on barriers

b)

B on barriers and on crane boom

c)

C at operators station and at base of the crane

d)

D at operators station and on the barriers

16.

16) according to OSHA, a frequent inspection is:

a)

A monthly to annually

b)

B daily to monthly

c)

C hourly to daily

d)

D daily to weekl

17.

17) according to OSHA, a periodic inspection is:

a)

A monthly to annually

b)

B daily to monthly

c)

C hourly to daily

d)

D daily to week

18.

18) cranes idle for more than 6 months must have inspections performed:

a)

A frequent and periodic

b)

B daily and weekly

c)

C daily

d)

D no inspection require

19.

19) cranes idle for less than 6 months must have inspections performed:

a)

A frequent and periodic

b)

B periodic

c)

C frequent

d)

D no inspection requireD no inspection required

20.

20) cranes lifting personnel platform must have the platform and rigging inspected:

a)

A prior to each shift

b)

B at least daily

c)

C prior to each lift

d)

D at least monthly

21.

21) Per OSHA, crane hooks must not be twisted in excess of:

a)

A 10°

b)

B 15°

c)

C 20°

d)

D 5°

22.

22) Per OSHA, a cranes hook's throat opening must not exceed:

a)

A 10% of its original size

b)

B 15% of its original size

c)

C 20% of its original size

d)

D 25% of its original size

23.

23) by oder of hitch strength, which is the correct answer:

a)

A vertical, basket, choker

b)

B basket, vertical, choker

c)

C basket, choker, vertical

d)

D choker, basket, vertica

24.

24) according to ASME B30.3 and OSHA, you should always have at least how many wraps on a hoist drum:

a)

A 5

b)

B 2

c)

C 3

d)

D 1

25.

25) what is the minimum allowable distance from the crane and power lines under 50 kV:

a)

A 25 feet

b)

B 10feet

c)

C 15 feet

d)

D 20 feet

26.

26) according to ASME B30.3, how many randomly broken wires must there be to remove a running wire rope from service:

a)

A 12

b)

B 3

c)

C 5

d)

D 6

27.

27) according to ASME B30.3, working near power lines when is the signal person required:

a)

A when crane moves within 10 feet of the power lines

b)

B when crane moves within 15 feet of the power lines

c)

C when crane moves within a booms length of the power lines

d)

D when crane moves within a Jibbs length of the power lines

28.

28) according to OSHA, after the crane is been checked out and before personnel lift operations begin the crew should:

a)

A have lunch

b)

B have a pre-left meeting

c)

C check the oil in the engine

d)

D inspect the cab for debris

29.

29) according to OSHA, when is it safe to work closer than the allowable distance from the power lines:

a)

A when crane owner says lines are de-energized

b)

B when site supervision says lines are de-energized

c)

C when utility company says lines are de-energized

d)

D when lead in ginger says lines are de-energized

30.

30) when should a tagline being used:

a)

A when rotation of the load would be dangerous

b)

B when raining and lotus slippery

c)

C when only one signal person is required

d)

D never

31.

31) what is the minimum design factor required for a boom hoist rope:

a)

A 5.55

b)

B 3.55

c)

C 2.55

d)

D 7.55

32.

32) how many broken wires must be present in one strand of one lay for running wire rope to be removed from service:

a)

A 3

b)

B 4

c)

C 2

d)

D 6

33.

33) what is the maximum permitted wind speed when climbing a tower:

a)

A 10 mph

b)

B 15 mph

c)

C 20 mph

d)

D 25 mph

34.

34) according to ASME B30.3, a crane should be plum to:

a)

A 1 to 500

b)

B 1 to 400

c)

C 1 to 300

d)

D 1 to 200

35.

35) according to ASME B30.3, the rated load under static conditions shall not exceed ___ of calculated tipping loads:

a)

A 63%

b)

B 73%

c)

C 75%

d)

D 77%

36.

36) according to ASME B30.3, an overhead power line is always considered to be:

a)

A energize until the power company has verified is not energized

b)

B safe as long as the load, hoist rope and structure are at least 10 feet away

c)

C de-energize if there is not power on the job site

d)

D de-energize if the lines have a safety cover over them

37.

37) high-tensile bolts shall be marked with manufacturers designation and:

a)

A tensile grade

b)

B strength rating

c)

C bolt size

d)

D torque requirements

38.

38) bolt connections for tower sections must use high-tensile strength nuts with ratings of:

a)

A 32

b)

B 12

c)

C 22

d)

D 42

39.

39) washers used in high-tensile bolt connections shall be marked with:

a)

A HV

b)

B HC

c)

C CV

d)

D W

40.

40) before installation high-tensile bolt connection components shall be cleaned and visually examined for:

a)

A shape and color

b)

B width and weight

c)

C weight and color

d)

D damage and corrosion

41.

41) when ready to torque the nut on a high-tensile bolt connection you should:

a)

A lubricate nothing

b)

B lubricate threads

c)

C lubricate bolt head

d)

D lubricate washers

42.

42) during tightening of high-tensile connections the bolt is stretched to a specific percentage of its elastic limit at the correct:

a)

A torque

b)

B length

c)

C shape

d)

D count

43.

43) preferably the tightening torque shall be applied to the:

a)

A washer

b)

B shaft

c)

C nut

d)

D bol

44.

44) the tightening torque values placed on the nuts and bolts of high-tensile bolt connection are dependent on the:

a)

A weight and shape

b)

B color and length

c)

C label and ballast

d)

D type and size

45.

45) what components of a tower crane are connected with high-tensile bolt connections:

a)

A ballast weights,operator cab, tower section

b)

B counter jib cable, ballast weights, anchors

c)

C catwalk, ladders, jib point

d)

D foundation anchors, tower sections, slewing ring support

46.

46) when the tower base bolts are torqued the counter jib should be positioned:

a)

A 0° from the bolt

b)

B 45° from the bolt

c)

C 90° from the bolt

d)

D 180° from the bold