AC 2.3 MDPE Water Supply Quiz

Total questions: 21

Worksheet time: 11mins

Name
Class
Date
1.

What is the standard size of the MDPE water supply for most domestic installations?

a)

20mm

b)

25mm

c)

30mm

d)

35mm

2.

What determines the pipe size after the MDPE water supply enters the building?

a)

The color of the pipes

b)

The type of flooring

c)

The appliances and components installed

d)

The height of the building

3.

What should be carried out to determine the exact pipe size required?

a)

Pipe coloring

b)

Pipe sizing

c)

Pipe cleaning

d)

Pipe painting

4.

What size of pipework is generally used in direct systems for cold water outlets?

a)

10mm

b)

15mm

c)

20mm

d)

25mm

5.

In what type of installations is a 15mm rising main sufficient?

a)

Large installations with multiple en-suite bathrooms

b)

Small installations with a combination boiler

c)

Industrial installations

d)

Installations with multiple shower rooms

6.

Where does the cold water rising main terminate in an open vented hot water storage system?

a)

In the basement

b)

In the kitchen

c)

In the roof space

d)

In the bathroom

7.

What must the water storage capacity of the cistern be in relation to the hot water storage vessel?

a)

Less than the hot water storage vessel

b)

Equal to or greater than the hot water storage vessel

c)

Twice the hot water storage vessel

d)

Half of the hot water storage vessel

8.

What is the minimum size of the cold water rising main required for an unvented hot water storage system?

a)

15mm

b)

18mm

c)

22mm

d)

25mm

9.

Why do unvented hot water storage systems require a larger size pipe?

a)

To reduce installation costs

b)

To increase water temperature

c)

To achieve a greater flowrate

d)

To decrease water pressure

10.

What happens to the number of outlets when hot water is supplied directly from the mains cold water supply through a mains pressure hot water heater?

a)

The number of outlets is halved.

b)

The number of outlets remains the same.

c)

The number of outlets is effectively doubled.

d)

The number of outlets is reduced by a quarter.

11.

What might be required occasionally depending on the size of the property and the number of outlets being supplied?

a)

A 15mm rising main

b)

A 22mm rising main

c)

A 28mm rising main

d)

A 35mm rising main

12.

What is the purpose of the indirect system of cold water supply?

a)

To increase water pressure in high-pressure areas

b)

To supply hot water to the entire building

c)

To provide water in areas with low cold water supply pressure

d)

To reduce water usage in residential areas

13.

What size is the cold water rising main used in the indirect system?

a)

10mm

b)

15mm

c)

20mm

d)

25mm

14.

Where are the cold water storage cisterns located in the indirect system?

a)

In the basement

b)

On the ground floor

c)

In the roof space

d)

In the garden

15.

Which fixtures are directly taken off the cold water main in the indirect system?

a)

All bathroom fixtures

b)

The kitchen sink and possibly a downstairs cloakroom or utility room

c)

Only the garden hose

d)

All fixtures in the house

16.

What is the minimum pipework size used for low pressure supply in cold distribution pipework?

a)

15mm

b)

22mm

c)

28mm

d)

35mm

17.

What size pipework is often used for cold distribution pipework depending on the number of outlets?

a)

15mm

b)

22mm

c)

28mm

d)

35mm

18.

What is the purpose of supplying 22mm pipework to the bath?

a)

To reduce water pressure

b)

To increase water temperature

c)

To give a good flowrate

d)

To decrease water flow

19.

Why should cold water storage cisterns be positioned as high as possible?

a)

To reduce the cost of installation

b)

To increase water temperature

c)

To provide adequate pressure

d)

To minimize water usage

20.

What must cold water storage cisterns be protected against?

a)

Excessive sunlight and rain

b)

Undue warming and frost

c)

Dust and insects

d)

High winds and humidity

21.

Why is it important to carefully calculate the amount of cold water stored in the roof space?

a)

To ensure the cisterns are lightweight

b)

To prevent water overflow

c)

To supply both cold and hot water needs

d)

To reduce water evaporation