PPT 2 - Central heating system principles

Total questions: 28

Worksheet time: 14mins

Name
Class
Date
1.

What does the term 'gravity circulation' refer to in older systems?

a)

Use of a pump to circulate heat

b)

Principle of convection to circulate heat

c)

Use of electricity to circulate heat

d)

Principle of radiation to circulate heat

2.

Why are modern CH systems more efficient than older systems?

a)

They use larger pipes

b)

They incorporate a circulator or pump

c)

They rely solely on gravity

d)

They use less energy

3.

What is a characteristic of a 'C Plan' system?

a)

It uses only gravity for all circuits

b)

It uses only pumps for all circuits

c)

It combines pumped heating circuits with gravity for hot water primary circuits

d)

It uses solar power for heating

4.

What is a drawback of the one-pipe semi-gravity system?

a)

It requires multiple boilers.

b)

It results in each radiator being progressively cooler.

c)

It is more costly to install.

d)

It uses a complex circuit system.

5.

What is the diameter of the primary flow pipe in a one-pipe semi-gravity system?

a)

15mm

b)

22mm

c)

28mm

d)

35mm

6.

What is one advantage of a one-pipe semi-gravity system?

a)

High efficiency

b)

Cheap to install

c)

Compliant with Building Regulations part L

d)

Controlled room temperature

7.

Why might a one-pipe semi-gravity system not be compliant with Building Regulations part L?

a)

It is too expensive

b)

It uses high efficiency boilers

c)

It has uncontrolled room temperature

d)

It is cheap to install

8.

What is the primary function of the open vent pipe in a one-pipe semi-gravity system?

a)

To increase water pressure

b)

To provide a safety outlet

c)

To reduce water temperature

d)

To block air escape

9.

Why should the open vent pipe not have any valves attached?

a)

It could increase water flow

b)

It could cause overheating

c)

It could have disastrous effects if blocked

d)

It could reduce system efficiency

10.

What does the open vent allow while filling the system with water?

a)

Water to escape

b)

Air to escape

c)

Heat to escape

d)

Pressure to increase

11.

What is the minimum diameter required for an open vent pipe in a one-pipe semi-gravity system?

a)

15mm

b)

22mm

c)

30mm

d)

50mm

12.

Why is an open vent pipe fitted in a one-pipe semi-gravity system?

a)

To increase water pressure

b)

To ensure atmospheric pressure and prevent boiling point from exceeding 100°C

c)

To reduce water flow

d)

To increase system temperature

13.

What is the recommended minimum height for the open vent pipe above the water level of the feed & expansion cistern?

a)

200mm

b)

350mm

c)

450mm

d)

600mm

14.

What is the maximum distance allowed between the open vent and the cold feed in a one-pipe semi-gravity system?

a)

100mm

b)

150mm

c)

200mm

d)

250mm

15.

What is the term used to describe the point where the circulating pump acts on both the feed pipe and the open vent pipe with equal suction?

a)

Balance point

b)

Neutral point

c)

Equilibrium point

d)

Central point

16.

What happens if the open vent and cold feed are positioned further apart than the maximum allowed distance?

a)

The neutral point becomes stronger

b)

The pump acts on the open vent pipe with greater force

c)

The neutral point becomes weak

d)

The system shuts down

17.

What is the common capacity of a Feed and Expansion (F&E) cistern?

a)

10 litres

b)

18 litres

c)

25 litres

d)

30 litres

18.

Where should the 15mm cold feed be located in relation to the F&E cistern?

a)

On top of the F&E cistern

b)

Below the F&E cistern

c)

To the side of the F&E cistern

d)

Inside the F&E cistern

19.

What is the minimum height the F&E cistern should be located above the circulator?

a)

0.5m

b)

1m

c)

1.5m

d)

2m

20.

What is one of the purposes of installing an F&E cistern in a one-pipe semi-gravity system?

a)

To increase water pressure

b)

To provide static head for the heating system

c)

To reduce water temperature

d)

To filter impurities from the water

21.

How does an F&E cistern help maintain the heating system?

a)

By cooling the water

b)

By keeping the system topped up after slight water loss

c)

By reducing system pressure

d)

By increasing water flow speed

22.

What is another function of the F&E cistern besides providing static head?

a)

To accommodate system expansion

b)

To decrease water flow

c)

To purify the water

d)

To increase system noise

23.

What is the role of the room thermostat in the two-pipe semi-gravity system?

a)

It controls the temperature of the hot water

b)

It switches off the pump

c)

It mixes the flow and return waters

d)

It increases the water pressure

24.

Why do the flow and return waters not mix in a two-pipe semi-gravity system?

a)

To prevent water contamination

b)

To allow heat emitters to achieve the same temperature

c)

To reduce water pressure

d)

To increase water flow speed

25.

Which component in a two-pipe semi-gravity system controls the pump?

a)

Boiler

b)

Programmer

c)

Room thermostat

d)

Vent pipe

26.

What is the diameter of the cold feed pipe in a two-pipe semi-gravity system?

a)

15mm

b)

22mm

c)

28mm

d)

30mm

27.

What is one advantage of a two-pipe semi-gravity system?

a)

Uncontrolled heat

b)

Boiler cycling

c)

All heat emitters reach the same temperature

d)

Not compliant to Building Regulations part L

28.

Which of the following is a disadvantage of a two-pipe semi-gravity system?

a)

Cheaper to run

b)

Quicker when heating up

c)

Boiler cycling

d)

All heat emitters reach the same temperature