NEW
Font size
S
M
L
XL
WorksheetsD29 QUIZ OF THE DAY
Total questions: 25
Worksheet time: 13mins
Name
Class
Date
1.
Assertion (A): Stack effect improves indoor air quality.
Reason (R): Warm air rises and exits through upper vents, drawing in cooler air.
a)
Both A and R are true, and R is the correct explanation of A
b)
Both A and R are true, but R is not the correct explanation of A
c)
A is true but R is false
d)
A is false but R is true
2.
Assertion (A): Grouping of rooms improves privacy and utility.
Reason (R): Grouping places the kitchen near the bathroom for easy access.
a)
Both A and R are true, and R is the correct explanation of A
b)
Both A and R are true, but R is not the correct explanation of A
c)
A is true but R is false
d)
A is false but R is true
3.
Assertion (A): Vertical circulation allows access to upper floors.
Reason (R): It is provided by ramps, stairs, and elevators.
a)
Both A and R are true, and R is the correct explanation of A
b)
Both A and R are true, but R is not the correct explanation of A
c)
A is true but R is false
d)
A is false but R is true
4.
Assertion (A): Fire escape staircases are mandatory in high-rise buildings.
Reason (R): High-rise buildings have more than four floors or are 16 m high.
a)
Both A and R are true, and R is the correct explanation of A
b)
Both A and R are true, but R is not the correct explanation of A
c)
A is true but R is false
d)
A is false but R is true
5.
Assertion (A): The key map must indicate the north direction and landmarks.
Reason (R): It is submitted along with the building permit to identify the site location.
a)
Both A and R are true, and R is the correct explanation of A
b)
Both A and R are true, but R is not the correct explanation of A
c)
A is true but R is false
d)
A is false but R is true
6.
What is the minimum clear width of access required for a multiple occupancy two-storey building?
a)
1.2 m
b)
2.0 m
c)
3.6 m
d)
5.0 m
7.
Minimum vertical clearance from a high voltage line (up to 33 kV) to a building is:
a)
2.5 m
b)
3.0 m
c)
3.7 m
d)
4.0 m
8.
What is the recommended aspect for a kitchen?
a)
West
b)
East
c)
North
d)
South
9.
Minimum height of a bathroom or latrine in residential buildings is:
a)
2.0 m
b)
2.1 m
c)
2.2 m
d)
2.4 m
10.
In public buildings, vertical circulation area should be at least what percent of floor area?
a)
4%
b)
6%
c)
8%
d)
10%
11.
According to KMBR, a high-rise building must have at least:
a)
One staircase
b)
Two staircases
c)
Three staircases
d)
No requirement
12.
Recommended slope for Mangalore tile roof is:
a)
1/4 to 1/3 of span
b)
1/3 to 1/2 of span
c)
1/5 of span
d)
1/6 of span
13.
Minimum area required for a habitable room is:
a)
6.5 sq.m
b)
7.5 sq.m
c)
9.5 sq.m
d)
10.0 sq.m
14.
Which color is used to indicate a proposed building in plan drawings?
a)
Red outline
b)
Black outline
c)
Yellow hatching
d)
Green line
15.
What is the maximum allowed coverage for a mercantile/commercial building?
a)
50%
b)
60%
c)
65%
d)
70%
16.
What is the ideal front setback for a residential building on a 10 m wide road?
a)
1.5 m
b)
3.0 m
c)
4.5 m
d)
6.0 m
17.
Minimum side open space for a detached building is:
a)
1.5 m
b)
2.0 m
c)
3.0 m
d)
4.0 m
18.
In building bye-laws, 'setback line' refers to:
a)
Line up to which roof projects
b)
Line from which the street starts
c)
Line beyond which no construction is allowed
d)
None of the above
19.
Minimum rear open space for a plot less than 9 m deep is:
a)
1.8 m
b)
2.4 m
c)
3.0 m
d)
1.5 m
20.
How much additional side/rear yard is required per 3 m building height beyond 10 m?
a)
0.25 m
b)
0.5 m
c)
0.75 m
d)
1.0 m
21.
Recommended ventilation air rate for a restaurant is:
a)
17 m³/h per person
b)
25 m³/h per person
c)
35 m³/h per person
d)
60 m³/h per person
22.
Minimum height of parapet wall for telecommunication tower protection is:
a)
0.9 m
b)
1.0 m
c)
1.2 m
d)
1.5 m
23.
Minimum plot size for a detached residential building is:
a)
50 sq.m
b)
125 sq.m
c)
200 sq.m
d)
250 sq.m
24.
In residential planning, ideal breadth-to-length ratio of room is:
a)
1:1
b)
1:1.2 to 1:1.5
c)
1:2
d)
2:1
25.
Minimum carpet area required for a market stall is:
a)
5 m²
b)
10 m²
c)
15 m²
d)
20 m²
Reset