Wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

GMJ 6035 requirements of drainage

Total questions: 29

Worksheet time: 15mins

Name
Class
Date
1.

What is the purpose of the vent pipe in a soil stack?

a)

To carry waste

b)

To provide a backup pipe

c)

To allow air into the system and prevent pressure variations

d)

To supply water

2.

What is the minimum water seal depth required in a trap?

a)

25mm

b)

32mm

c)

50mm

d)

75mm

3.

Which British Standard covers gravity drainage systems inside buildings?

a)

BS 8000

b)

BS 6465

c)

BS EN 12056

d)

BS 7671

4.

What is the maximum horizontal pipe length for a 32mm basin waste?

a)

2.0m

b)

1.7m

c)

3.0m

d)

1.0m

5.

What type of system includes a secondary vent connected from just above the long radius bend?

a)

Stub stack

b)

Primary ventilated stack

c)

Secondary ventilated stack

d)

Ventilated branch system

6.

In a ventilated branch system, how close must the branch vent be to the appliance?

a)

1.5m

b)

750mm

c)

2m

d)

600mm

7.

What should be installed if a soil stack terminates internally?

a)

Air admittance valve

b)

Rainwater gully

c)

Inspection chamber

d)

Stub stack

8.

At what height above the spillover level should an air admittance valve be installed?

a)

500mm

b)

2m

c)

1m

d)

750mm

9.

What is used to prevent foul air from entering a building through the drainage system?

a)

Rainwater gulley

b)

Trap

c)

Soakaway

d)

Manifold

10.

What type of below-ground system keeps foul and rainwater separate?

a)

Combined system

b)

Partially separate system

c)

Separate system

d)

Gravity system

11.

What is the maximum clipping distance for 110mm vertical plastic pipework?

a)

1.0m

b)

2.0m

c)

1.2m

d)

1.5m

12.

Which of the following is a hazard specifically linked with contact with water contaminated by rat urine?

a)

Hepatitis

b)

Dermatitis

c)

Weil’s disease

13.

What is a stub stack typically capped off with?

a)

Weather collar

b)

Access cap

c)

Trap

d)

Manifold

14.

What is the maximum allowable distance a stub stack can be from the main vented stack?

a)

4m

b)

5m

c)

6m

d)

10m

15.

What feature must be installed between floors in flats when the soil stack is internal?

a)

Soakaway

b)

Manifold

c)

Intumescent collar

d)

Strap boss

16.

Which system allows recycling of water from showers and basins to flush WCs?

a)

Stub stack system

b)

Grey water recovery system

17.

What angle should discharge branches ideally fall at?

a)

1 degree

b)

2.5 degrees

c)

5 degrees

d)

10 degrees

18.

If a discharge pipe exceeds the max length for its size, what should be done?

a)

Increase gradient

b)

Install a vent

c)

Use the next pipe size up

d)

Add an access point

19.

What is the nominal diameter of waste pipe for a washing machine?

a)

32mm

b)

40mm

c)

50mm

d)

75mm

20.

What prevents rainwater from falling into a vented soil stack?

a)

Access cover

b)

Cowl

c)

Grating

d)

Trap

21.

What is the purpose of a long radius bend at the base of a soil stack?

a)

To slow down the effluent flow

b)

To allow for easier access

c)

To maintain velocity and reduce back pressure

d)

To separate rainwater from waste water

22.

What is a strap boss used for?

a)

Capping off a pipe

b)

Making a vent connection

c)

Connecting a waste pipe to the soil stack

d)

Supporting a vertical pipe

23.

Which of the following is not an acceptable method of connecting to a soil stack?

a)

Strap boss

b)

Boss branch

c)

Saddle tee

d)

Collared boss

24.

What is the minimum branch ventilating pipe size for multiple appliances in a ventilated branch system?

a)

25mm

b)

32mm

c)

40mm

d)

50mm

25.

What must be provided above the spillover level of the highest appliance in a stack system?

a)

Gully trap

b)

Parallel junction

c)

Access for clearing blockages

d)

Stub stack

26.

In the event of an internal air admittance valve installation, which of the following is required?

a)

Soakaway system

b)

External cowl

c)

Sufficient ventilation and access for maintenance

d)

Weatherproofing collar

27.

Which system allows all drainage pipes to be connected without additional ventilation due to close grouping of appliances?

a)

Stub stack system

b)

Ventilated branch system

c)

Secondary ventilated stack

d)

Primary ventilated stack

28.

What advantage does a combined below-ground system offer?

a)

Easier to separate rainwater

b)

Reduced treatment cost

c)

Impossible to make an incorrect connection

d)

Rainwater does not need to be treated

29.

Which infection is linked with poor personal hygiene and contact with human waste?

a)

Dermatitis

b)

Hepatitis A

c)

Legionella

d)

Leptospirosis