Building System Services: Lighting and Ventilation Codes

Total questions: 111

Worksheet time: 56mins

Name
Class
Date
1.

According to the Philippine Green Building Code (PGBC) lighting provisions, which design goal for daylight provision is emphasized?

a)

Increase reliance on artificial lighting for consistent illuminance

b)

Maximize natural light to reduce artificial lighting use in regularly occupied spaces

c)

Avoid windows in daylight zones to minimize glare

d)

Use only clerestories instead of skylights for compliance

2.

In daylight-controlled lighting systems, what is the required installation depth for daylight sensors when occupancy sensors are also used?

a)

At the ceiling plane to detect occupancy only

b)

At least at the window sill level for maximum daylight response

c)

At half the depth of the daylight zone so they can override daylight sensors when no presence is detected

d)

At the back of the room to avoid glare

3.

Which statement about Light Power Density (LPD) is correct?

a)

LPD measures luminous flux per luminaire

b)

LPD is the electrical power used for lighting per unit of area, typically expressed in watts per square meter

c)

LPD is a ratio of window area to floor area

d)

LPD measures daylight factor at the work plane

4.

Under Section 808 (Window Openings), what is the minimum total opening area required for windows in rooms without artificial ventilation, and what must these windows open to?

a)

At least 5% of floor area; open to any interior corridor

b)

At least 10% of floor area; open to a court, yard, public street, alley, or open watercourse

c)

At least 15% of floor area; open to a mechanical shaft

d)

At least 20% of floor area; open to an atrium only

5.

Section 809 outlines vent shaft requirements. Which combination of minimum duct/intake dimensions is correct?

a)

Unobstructed cross-sectional area: 0.20 square meters; minimum dimension: 200 millimeters

b)

Unobstructed cross-sectional area: 0.30 square meters; minimum dimension: 300 millimeters; openings at least 300 millimeters above the shaft bottom and street/court surface

c)

Unobstructed cross-sectional area: 0.50 square meters; minimum dimension: 150 millimeters

d)

Unobstructed cross-sectional area: 0.10 square meters; minimum dimension: 100 millimeters

6.

Which statements are requirements for skylights under Section 810 (Ventilation Skylights)? Select all that apply.

a)

Skylights must have at least the same glass area as the windows they replace

b)

Skylights must include movable sashes or louvers with a free area equal to the operable parts of the replaced window

c)

Skylights are exempt from providing approved artificial ventilation

d)

Skylights must always be fixed and non-operable

7.

Under Section 801 (General Requirements of Light and Ventilation), which condition is mandated for building design and construction?

a)

Buildings may disregard easements of light and view if mechanical ventilation is installed

b)

Every building shall be designed, constructed, and equipped to provide adequate light and ventilation, consistent with the Civil Code provisions on Easements of Light and View

c)

Window areas may be reduced below code requirements if a new room is added

d)

Buildings can be enlarged even if court or yard dimensions fall below prescribed sizes

8.

Boilers must include several critical safety devices. Which device is specifically intended to relieve excess pressure to prevent dangerous overpressure conditions?

a)

Pressure gauges

b)

Safety valves

c)

Water level indicators

d)

Temperature controls

9.

According to HVAC general requirements, which statement best describes how ventilation air should be distributed within occupied zones to avoid stagnant areas?

a)

Delivered only near exterior walls to promote perimeter cooling

b)

Supplied primarily at ceiling level with minimal mixing

c)

Distributed uniformly throughout the occupied zone

d)

Concentrated near return grilles to enhance extraction

10.

The code specifies minimum ventilation rates and gives example standards for typical spaces. Which pairing correctly matches the space type with its approximate outdoor air requirement per person?

a)

Offices/Classrooms: ~12–15 L/s per person

b)

Assembly halls/Theaters: ~7–10 L/s per person

c)

Hospitals/Clinics: ~10–15 L/s per person

d)

Kitchens: higher ACH due to odor, heat, and grease removal

11.

Which combination of HVAC air intake requirements is correct? Select all that apply.

a)

Air intakes should be elevated above ground level to minimize intake of dust and pollutants.

b)

Minimum horizontal and vertical clearances between outdoor air intakes and exhaust outlets must be provided to prevent re-entrainment.

c)

Fresh air intakes may be located adjacent to garbage bins if filtration is installed.

d)

Air intakes must be located away from sources of contamination, such as exhaust outlets and pollutant-emitting facilities.

12.

For duct systems, which design and construction practices are required to maintain efficiency and integrity? Select all that apply.

a)

Use of approved materials, sealed to prevent leakage, and insulated where necessary to reduce heat loss, condensation, and noise.

b)

Provision of access panels for cleaning, maintenance, and inspection of ducts and equipment.

c)

Installation of fire and smoke dampers where ducts penetrate fire-rated walls or floors.

d)

Sizing ductwork primarily for maximum static pressure without regard to frictional losses.

13.

Hydronics is defined in this section as which of the following?

a)

The use of air as a medium for cooling systems in buildings

b)

The science and application of using water or other fluids as a medium for heating and cooling systems in buildings

c)

The process of ventilating buildings using natural openings and stack effect

d)

The arrangement of refrigerants for food storage applications

14.

Which measures are specified to protect water quality in hydronic systems? Select all that apply.

a)

Proper water treatment to prevent corrosion, scaling, and microbial growth

b)

Monitoring devices installed to maintain water quality

c)

Expansion tanks and pressure relief valves to prevent overpressure

d)

Backflow preventers to avoid contamination of potable water supplies

15.

Refrigeration systems have broad applications and involve hazards if mishandled. Which statement aligns with the section’s emphasis?

a)

Refrigeration systems are mainly used in industrial power generation, with minimal relevance to healthcare.

b)

They are widely applied in food storage, healthcare, and air conditioning, and improper handling of refrigerants can pose hazards to health and the environment.

c)

Refrigeration is limited to air conditioning; food storage uses only hydronics.

d)

Refrigerant hazards are negligible if systems are sealed during manufacturing.

16.

According to the requirements for rooms housing combustion equipment, which statement best describes how combustion air must be provided to avoid backdrafting of flue gases?

a)

Air must be supplied solely from adjacent rooms via transfer grilles.

b)

Air supply should be provided through direct openings to the outdoors or by mechanical means, meeting minimum free area and configuration requirements.

c)

Combustion air is unnecessary if the room has a window that can be opened.

d)

Air should only be provided from conditioned spaces to maintain thermal comfort.

17.

Chimneys, vents, and flues must meet which combined set of requirements to safely discharge combustion by-products to the outdoors?

a)

Use non-combustible, durable materials resistant to corrosion and heat

b)

Include decorative lining to improve aesthetic appeal

c)

Prevent backflow of gases into occupied spaces

d)

Install intake dampers to draw room air into the chimney

e)

Observe clearance requirements between flues and combustible materials

18.

Which exhaust classification is defined as exhaust air that may be moderately contaminated or contain odors, but not hazardous/toxic, and what is the minimum separation from outdoor air intakes stated for it?

a)

Class 2 exhaust; 3 meters

b)

Class 2 exhaust; 5 meters

c)

Class 3 exhaust; 3 meters

d)

Class 3 exhaust; 5 meters

19.

For Class 3 exhaust, which example and treatment statement align with its definition of heavily contaminated, potentially toxic exhaust?

a)

Janitor closets; discharge directly outdoors without separation

b)

Kitchen grease hoods; require ducting to the outdoors with increased separation and treatment due to contamination

c)

Restroom exhaust; can mix with return air if filtered

d)

General laboratory spaces with non-toxic chemicals; recirculate after odor control

20.

Smoke control and fire stop protection systems must meet which requirements to limit the spread of smoke and fire within buildings?

a)

HVAC systems must not contribute to the spread of smoke or fire within buildings.

b)

Penetrations of ducts through fire-rated walls and floors must be sealed using fire stops or equipped with automatic dampers.

c)

Materials used in ducts and insulation must be appropriate fire-resistance ratings.

d)

Smoke control is optional in high-rise buildings and hospitals.

21.

Vertical transportation refers to systems that allow people to move between different levels of a building. Which statement correctly identifies its primary goal and common types?

a)

Primary goal is energy efficiency; common types are conveyors and moving walkways.

b)

Primary goal is accessibility for all users; common types include stairs, lifts (elevators), escalators, and ramps.

c)

Primary goal is aesthetic enhancement; common types are atriums and mezzanines.

d)

Primary goal is emergency egress only; common types are fire escapes and ladders.

22.

Which stair type consists of two straight flights running in opposite directions with no space between them in plan view, with the landing at the midpoint providing a turn in direction?

a)

Straight stair

b)

Dog-legged stair

c)

Geometrical stair

d)

Quarter turn newel stair

23.

Which statement best describes the primary function of ramps in buildings as presented: sloping surfaces that connect one level to another and provide an accessible pathway for people and, in some cases, vehicles.

a)

Flat platforms that offer resting areas only

b)

Sloping surfaces that connect one level to another for accessible movement

c)

Mechanical systems that lift passengers vertically

d)

Curved stairways used for emergency egress

24.

For accessibility, what is the maximum slope gradient specified for wheelchair users on ramps?

a)

1:20 (5%)

b)

1:16 (6.25%)

c)

1:12 (8.33%)

d)

1:10 (10%)

25.

Which combination of ramp design requirements is correct according to the specifications provided? Select all that apply.

a)

Minimum clear width of 1.2 m for pedestrian ramps

b)

Intermediate landings every 750 mm rise

c)

Handrails required on both sides if rise exceeds 150 mm

d)

Surface finish must be non-slip in all weather conditions

26.

Which elevator type is designed for virtually limitless rise and is suitable for high‑rise and midrise buildings but comes with higher installation costs?

a)

Hydraulic elevator

b)

Traction (electrical) elevator

c)

Pneumatic elevator

d)

Rack-and-pinion elevator

27.

Hydraulic elevators, as described, are limited to about 60 feet (around 6 stories) and operate at lower speeds, making them better for low‑ to mid‑rise buildings. What is a typical trade-off mentioned?

a)

Lower initial cost but higher operating costs due to greater power consumption

b)

Higher initial cost but lower operating costs due to energy recovery

c)

Highest speed with lowest maintenance needs

d)

Unlimited rise with minimal power use

28.

Match each ramp type to its defining characteristic.

a)

Straight ramp: single continuous slope without turns

b)

Dog‑legged ramp: two inclined planes with an intermediate landing

c)

Circular/curved ramp: continuous curved path used in parking buildings

d)

Zigzag/switchback ramp: repeated multiple times to cover greater height differences

29.

According to Section 501 – Testing of Systems, which test requirement applies to water, drainage, and vent piping?

a)

Hydrostatic test using 100 psi for 5 minutes

b)

Smoke test using 5" water column for 10 minutes

c)

Water test using minimum 3 m head or air test at 34.5 kPa for 15 minutes to detect leaks

d)

Ultrasonic leak detection for all joints

30.

What is the stated purpose of grease traps and interceptors required for restaurants and food establishments?

a)

Increase flow velocity in pipes

b)

Prevent sewer blockages and environmental hazards from commercial and industrial wastes

c)

Reduce water consumption during peak hours

d)

Disinfect wastewater before discharge

31.

Which statement aligns with the abandonment requirements for septic tanks or cesspools after connection to a public sewer?

a)

Leave tanks in place and mark location; no further action

b)

Empty and fill with approved materials within 30 days, install dry compacted soil with watertight joints

c)

Flush tanks and leave open for inspection for 60 days

d)

Relocate tanks to a new site without filling

32.

In a building’s water supply system, which statement aligns with the Revised National Plumbing Code regarding fixture piping requirements?

a)

A standard water closet requires a 25 mm supply pipe and a 150 mm drainage pipe.

b)

A lavatory requires a 20 mm supply pipe and a 50 mm drainage pipe.

c)

A standard water closet requires a 20 mm supply pipe and a 200 mm drainage pipe.

d)

A urinal requires a 15 mm supply pipe and a 75 mm drainage pipe.

33.

Which wastewater disposal approach is correctly matched to its required application in areas without municipal sewer systems?

a)

Direct pumping of sewage to storm drains

b)

Imhoff tank or conventional septic tank with sub-surface absorption fields

c)

Discharge of sanitary sewage to open channels

d)

Neutralization of domestic wastewater before direct discharge to rivers

34.

For storm drainage in buildings, what is the primary compliance requirement for all drainage connections?

a)

Connect to any available terminal regardless of code

b)

Use only roof drains with proprietary filters

c)

Meet code standards and connect to approved terminals

d)

Discharge to sanitary sewer mains during heavy rain

35.

Which combination describes mandatory features of a grease trap used for kitchens producing grease-laden wastewater?

a)

Rectangular tank with three compartments

b)

First compartment containing 10–20% of tank volume

c)

Minimum access opening of at least 0.25 m diameter

d)

Located at least 25 meters from water sources and not under buildings

36.

Which material set best fits the description of approved plumbing fixture surfaces?

a)

Porous, absorbent, and rough surfaces to trap contaminants

b)

Dense, durable, non-absorbent, smooth, impervious, and acid-resistant porcelain enamel

c)

Lightweight plastic surfaces with high porosity for easy cleaning

d)

Uncoated concrete surfaces to increase friction and reduce splashing

37.

In electrical service-entrance conductors, what is the minimum conductor size requirement to safely carry load currents?

a)

At least 8 mm² copper or 14 mm² aluminum

b)

At least 2 mm² copper or 4 mm² aluminum

c)

At least 12 mm² copper or 20 mm² aluminum

d)

At least 6 mm² copper or 10 mm² aluminum

38.

Which item is a mandatory main switch and overcurrent protection provision for buildings according to the Philippine Electrical Code?

a)

Every building must have a single GFCI outlet on the ground floor.

b)

Every building must have a main disconnect switch with circuit breakers sized for the load to safely cut off power during faults.

c)

Every building must install surge protectors on all outlets.

d)

Every building must include automatic transfer switches for standby generators.

39.

Regarding grounding and bonding, which statement accurately reflects code requirements for protection against electrical faults?

a)

The grounding electrode can be connected to earth via rods, pipes, or rebar in foundations.

b)

Only non-metallic enclosures require bonding.

c)

All metal enclosures, conduits, and service equipment must be electrically connected to prevent dangerous voltage differences.

d)

The grounding conductor may be omitted if the service drop clearance exceeds 5.5 m above streets.

40.

Which statement best describes the purpose of ground-fault protection in large electrical services (approximately ≥1000 A, ≤600 V)?

a)

It prevents overheating by interrupting overcurrent conditions.

b)

It protects equipment from lightning surges entering the building.

c)

It prevents equipment damage and fires from line-to-ground faults.

d)

It eliminates the need for GFCI outlets in wet locations.

41.

In habitable rooms, receptacle distribution must be arranged so that no point is more than 1.8 m away from an outlet. What safety practice does this requirement help enforce?

a)

Providing emergency lighting when a circuit fails.

b)

Preventing use of unsafe extension cords.

c)

Ensuring every outlet is GFCI-protected.

d)

Allowing higher amperage circuits in living spaces.

42.

Which devices provide protection by opening the circuit to prevent overheating of wires and equipment?

a)

GFCI outlets

b)

Circuit breakers or fuses

c)

Surge suppressors

d)

Isolation transformers

43.

Which items are required or typical for emergency and special systems in public or large buildings? Select all that apply.

a)

Standby generators or batteries that start within 10 seconds of power loss

b)

Fire alarm circuits in certain occupancies such as schools and hospitals

c)

Two separate lighting circuits in each room

d)

Dedicated LAN hubs for emergency communications

44.

Which communication systems categories typically require structured cabling in commercial buildings, as defined across different NEC sections?

a)

Phone systems

b)

Data systems

c)

Local Area Networks (LANs)

d)

Building Automation and Control Systems (BACS)

e)

HVAC equipment power feeders

45.

In small business phone systems, what is the primary role of a Key Service Unit (KSU)?

a)

To convert analog lines to fiber for long-distance calling

b)

To support a fixed number of phone lines and telephone extensions

c)

To supply emergency power to phones during outages

d)

To provide voicemail and call recording for all users

46.

Which definition most accurately describes a Local Area Network (LAN)?

a)

A data communication system allowing independent devices to communicate directly with each other within a moderately sized geographic area

b)

A single centralized mainframe replacing all PCs in a company

c)

A long-haul WAN connecting multiple cities over leased lines

d)

An analog bus for telephone sets within a building

47.

Select the minimum components typically present in a small LAN network.

a)

Computers

b)

Network Interface Cards (NICs)

c)

Communication cables

d)

LAN hubs or switches

e)

PBX controllers

48.

Building Automation and Control Systems (BACS) commonly include which subsystems?

a)

HVAC (heating, ventilating, and air conditioning)

b)

Fire alarm

c)

Security, access control, and CCTV

d)

Mainframe terminals

49.

What is the core function of an HVAC control system within a building?

a)

Providing video surveillance and recording

b)

Regulating building temperature, humidity, and environmental conditions via centralized control and distributed thermostats

c)

Managing telephone extensions through a PBX

d)

Routing LAN traffic between hubs and switches

50.

Which statement best contrasts mainframe computers and minicomputers as described?

a)

Mainframes are smaller and used by a few terminals; minicomputers are larger and support hundreds of terminals.

b)

Both store data only on terminal disks; neither uses centralized disk drives.

c)

Mainframes are large centralized computers performing all computing, supporting many terminals; minicomputers are smaller, less powerful, with fewer terminals but still centralized.

d)

Minicomputers replaced LANs entirely in the 1980s.

51.

Which component in a fire alarm system is responsible for detection, suppression, and notification of fire conditions within a building?

a)

Sprinklers

b)

Sensors

c)

Centralized control panel

d)

Lights and horns

52.

In an access control system, access points are connected to the control unit using which of the following? Select all that apply.

a)

Communication cables

b)

A centralized control unit

c)

Magnetic contact readers

d)

Key pads

e)

A biometric sensing device

53.

Magnetic contact sensors primarily monitor which types of events on doors and windows within a building security system?

a)

Temperature changes and smoke levels

b)

Glass breaking, motion, or separation of contact points

c)

Unauthorized network access

d)

Elevator load and speed

54.

Which statement best describes the role of video surveillance in building security services?

a)

It only stores audio records for future reference.

b)

It acts as the ever-watchful eye providing a visual record of activity in and around the building.

c)

It replaces access control systems entirely.

d)

It is limited to external perimeter monitoring and cannot be used indoors.

55.

Which combination correctly lists typical components of a building sound system used for paging and announcements?

a)

Sound source, amplifier, communication cable, speakers

b)

Microphones, CCTV cameras, coaxial headend, monitors

c)

Sprinklers, thermostats, horns, control panel

d)

Biometrics scanner, keypads, ID cards, turnstiles

56.

Which items are common credentials or inputs used by access control systems to grant entry? Select all that apply.

a)

ID cards issued to authorized individuals

b)

Keypads that require a PIN code

c)

Biometrics using physical traits like fingerprints or facial recognition

d)

Visitor badges used for temporary identification

e)

Sprinkler activation signals

57.

What is the primary function of CCTV cameras within a Closed Circuit Television system as described?

a)

Provide Wi‑Fi connectivity for smart devices

b)

Capture footage of various areas, both internally and externally

c)

Broadcast live audio announcements across a campus

d)

Detect gas leaks and elevator malfunctions

58.

Which practices are part of effective visitor management systems in building security services? Select all that apply.

a)

Sign‑in procedures to register arrival and departure

b)

Issuing visitor badges for temporary identification

c)

Maintaining digital logs of visitor activity

d)

Automatic suppression of fires without human intervention

e)

Live paging announcements instead of registration

59.

According to the purpose of fire protection systems, which activity helps detect fires early in buildings and facilities?

a)

Using evacuation drills to guide occupants to exits

b)

Maintaining safe exit routes during normal operations

c)

Detecting fire through smoke, heat, or flame detection devices

d)

Separating hazards so no single fire can block all exits

60.

Select all functions that fire protection systems perform to protect life, property, and operations.

a)

Alerting occupants using alarms, signals, or communication systems to prompt safe evacuation

b)

Suppressing or controlling fire via sprinklers, extinguishers, standpipes, and other suppression equipment

c)

Supporting evacuation and safety measures by maintaining safe exit routes, emergency lighting, and fire drills

d)

Maximizing corridor width beyond 1200 mm to increase capacity

61.

In the context of life safety, what is the official term used for a safe way out of a building during an emergency?

a)

Emergency egress path

b)

Means of egress

c)

Exit discharge corridor

d)

Protected enclosure

62.

Which statement best defines the components of a means of egress?

a)

Exit access, exit, and exit discharge

b)

Exit access only, provided it leads to the street

c)

Exit discharge only, provided it leads to a courtyard

d)

Exit stairs only, provided they are enclosed

63.

Which protective enclosure requirements apply to exits connecting floors?

a)

Exits connecting up to 3 storeys must have a minimum 1-hour fire resistance

b)

Exits connecting 4 or more storeys must have a minimum 2-hour fire resistance built of noncombustible material

c)

Openings must be protected with self-closing fire doors

d)

Exit enclosures may serve other building functions to optimize space

64.

How is egress capacity determined for corridors and large stairways?

a)

By the total building area regardless of occupancy type

b)

By the clear width of components, with corridor capacity based on the last exit it leads to and large stairway capacity (≥1200 mm) possibly increased using a prescribed formula

c)

By the number of exits per storey only

d)

By the number of occupants per floor without considering component widths

65.

Which statements about occupant load are correct? Select all that apply.

a)

Occupant load equals the number of persons that may occupy a space, computed from floor area and occupancy type

b)

When exits serving multiple floors converge, the combined occupant load must be accommodated

c)

For balconies or mezzanines, occupant load is added to the space below if egress passes through it

d)

Occupant load is solely determined by corridor width, independent of occupancy type

66.

What is the minimum required width for means of egress, and what minor projections are permitted at low heights?

a)

Minimum width is 1000 mm; projections up to 200 mm allowed

b)

Minimum width is 915 mm; minor projections up to 114 mm allowed at low heights

c)

Minimum width is 800 mm; no projections allowed

d)

Minimum width is determined by occupancy and has no fixed lower bound

67.

How many exits are required based on occupant load thresholds?

a)

Minimum of two exits per storey, balcony, or mezzanine

b)

If occupant load is 500–1000, at least 3 exits

c)

If occupant load >1000, at least 4 exits

d)

Elevators count as exits when lobbies connect to at least one proper exit

68.

Which arrangement rules help ensure exits remain accessible and unobstructed by a single hazard?

a)

Exits must be accessible and connected by continuous passageways or corridors

b)

Without sprinklers, exits must be at least half the diagonal length of the area apart; with sprinklers, at least one-third the diagonal length apart

c)

Scissor or interlocking stairs are counted as a single exit

d)

Exits may be located so that a single fire can block all exits if corridor width exceeds 1200 mm

69.

What is the rule for dead-end corridors, hallways, or passageways unless specifically allowed?

a)

Dead-end spaces may extend up to 12 meters in all occupancies

b)

Dead-end spaces should not exceed 6 meters unless otherwise allowed in specific occupancy provisions

c)

Dead-end spaces are prohibited regardless of length

d)

Dead-end spaces must always include emergency lighting

70.

According to the egress capacity rules, how is the width for egress measured?

a)

With door partly open at 45° from the face to stop

b)

With door fully open at 90° from door face to stop

c)

From frame clear opening regardless of swing

d)

At the narrowest point of the corridor leading to the door

71.

For exit doors serving buildings with ≥4 storeys, what is the requirement regarding re-entry signage on stair doors?

a)

No signage is required if doors are self-closing

b)

Signs must be provided on every door indicating final exit only

c)

Non-reentry doors must have signs pointing to the nearest re-entry doors at least every 4 floors

d)

All stair doors must allow re-entry on every floor without signs

72.

Which statements are required for exit door operation and identification? Select all that apply.

a)

Exit doors must be side-hinged and swing in the direction of egress travel when serving ≥50 occupants or high-hazard areas

b)

Exit routes may pass through bathrooms and bedrooms in all occupancies

c)

Exits must be clearly recognizable, with no mirrors or decorations that confuse direction

d)

Exit doors may open directly onto stairs without a landing if corridor width is adequate

73.

What is the maximum allowable dead-end length for exterior exit access paths?

a)

3 m

b)

6 m

c)

9 m

d)

12 m

74.

Which of the following are minimum dimensional requirements for width and floor level at doors? Select all that apply.

a)

Minimum clear width 710 mm; in double doors, one leaf must be ≥710 mm

b)

Maximum single-leaf width 1,520 mm

c)

Floor level difference at doorways must not exceed 13 mm

d)

Thresholds: 13 mm high, bevel required if >6 mm

75.

Which statements correctly describe panic hardware requirements? Select all that apply.

a)

Panic hardware must unlatch with ≥7 kgf force

b)

Bars/panels must cover at least 2/3 of the door width and be 760–1,120 mm high

c)

Panic hardware may be disabled by locks or set screws

d)

Panic hardware must be operable without dogging devices

76.

Which devices must close automatically after release of hold-open and be easily closed manually if triggered?

a)

Screen and storm doors

b)

Power-operated doors

c)

Self-closing devices

d)

Turnstiles

77.

In buildings with more than 50 occupants per stair, what is the minimum cumulative width required per stair to satisfy egress requirements? Choose the option that matches the specified threshold-based width.

a)

1,120 mm for >50 occupants; 1,420 mm for ≥2,000 occupants

b)

900 mm for >50 occupants; 1,200 mm for ≥2,000 occupants

c)

1,050 mm for >50 occupants; 1,300 mm for ≥2,000 occupants

d)

1,200 mm for >50 occupants; 1,500 mm for ≥2,000 occupants

78.

Which statement correctly describes curved stair dimensional requirements for use as an egress stair?

a)

Treads must be ≥280 mm at 305 mm from the narrowest end, with radius ≥2× stair width

b)

Treads must be ≥250 mm measured at the inner radius, with radius ≥1.5× stair width

c)

Risers must be ≤180 mm and treads ≥300 mm at centerline, radius unrestricted

d)

Curved stairs are permitted without dimensional checks if handrails are on both sides

79.

Spiral stairs are allowed only if permitted by occupancy rules. Which combination of dimensions and features is required?

a)

Risers ≤180 mm

b)

Usable treads ≥280 mm

c)

Added clearance of 265 mm at the outer side

d)

Handrails on both sides

e)

Treads ≥250 mm at inner radius

80.

For small-occupant exception stairs (e.g., ≤35 occupants), which condition aligns with the documented criteria?

a)

Curved stair criteria are reduced along with width requirements

b)

Winders must be excluded and only straight runs allowed

c)

Treads may be reduced below 280 mm at any point

d)

No handrails are required if travel width is reduced

81.

Which requirement applies to guards and handrails along egress stairs?

a)

Handrails required on both sides, continuous, able to withstand ≥91 kg load

b)

Top of handrails must be 760–865 mm above tread nosings

c)

Minimum clearance from wall must be ≥38 mm

d)

Stairs wider than 2.23 m require intermediate handrails

e)

Guards ≥1.06 m high are only for exterior stairs and not mezzanines

82.

A horizontal exit is defined as a passage to an area of refuge on the same level. Which conditions must be met when substituting a horizontal exit for traditional exits?

a)

At least 50% of the capacity of other exits must remain (stairs, ramps, outside doors)

b)

For health care occupancies, at least two-thirds (≥2/3) capacity must remain

c)

Both buildings' separate egress must be maintained and accessible

d)

Doors must swing in opposite directions and never be locked

e)

Continuous paths of travel to stairways/exits must be provided on both sides

83.

For new construction bridges or balconies serving as horizontal exits, which door requirement is correct?

a)

Minimum width of 1.12 m for doors, with paired opposite-swing doors if both sides have exit travel

b)

Minimum width of 900 mm for doors; single swinging door acceptable regardless of travel direction

c)

Doors must be sliding type only, held open by occupancy during egress

d)

Doors may swing either direction; opposite-swing pairing is prohibited

84.

According to the fire escape stair requirements, which statement accurately describes the permissible use of fire escape stairs in buildings?

a)

Allowed in all new buildings if at least 50% of the required exit capacity is provided

b)

Allowed only in existing buildings where not more than 50% of the required exit capacity is assigned to fire escapes

c)

Prohibited in existing buildings but permitted in new high-rise constructions

d)

Allowed only in industrial buildings regardless of capacity calculations

85.

Which construction material specification meets the requirement for fire escape stairs?

a)

Wood construction with 244 kg/m² live load design

b)

Reinforced concrete designed for 488 kg/m² live load

c)

Aluminum construction designed for 91 kg force

d)

Gypsum board construction designed for 170 N load

86.

For slide escapes, which capacity limit is correct and aligned with the rules?

a)

Maximum 30 persons per exit unit

b)

Maximum 60 persons per exit unit

c)

Maximum 120 persons per exit unit

d)

No stated limit if used in manufacturing occupancies

87.

Which installation and design detail is required for fire escape ladders?

a)

Exit position must be at least 14 m above roof platform

b)

Rails 125×50 mm with diameter 22 mm

c)

Clearances 160–680 mm from wall depending on layout

d)

Lowest rung not more than 305 mm above ground

88.

Minimum illumination for means of egress must be maintained at 10.7 lux and arranged so bulb failure does not cause darkness. Which additional emergency lighting performance is required?

a)

Activate automatically within 10 seconds of power loss

b)

Provide required illumination for at least 1.5 hours

c)

Be connected only to public utility power

d)

Use only portable lamps as primary lighting

89.

Which statements about construction and compartmentation features of fire protection are correct?

a)

Buildings must be designed with fire-rated walls, barriers, and compartments to prevent fire spread

b)

Firewalls and barriers must comply with the National Building Code and NFPA 5000

c)

Damaged fire-rated materials must be replaced with non-rated alternatives to speed repairs

d)

High-rise and healthcare buildings need special quality assurance inspections for fire-resistive joints and barriers

90.

Which requirement applies to fire doors and stair enclosure doors?

a)

Must comply with NFPA 80 standards and have proper fire resistance rating

b)

Must be aluminum swing doors without self-latching

c)

Owners are not required to inspect or test fire doors after installation

d)

Reports on fire door testing are optional and not part of the Fire Safety Maintenance Report

91.

Which statements correctly describe smoke partitions?

a)

Smoke partitions are fire-resistive barriers that stop smoke from spreading

b)

They must extend fully, wall-to-wall and floor-to-floor, sealing all concealed spaces

c)

Openings for building services are widely allowed without restrictions

d)

Only necessary openings are allowed, such as doors or building services

92.

In buildings with sprinkler systems, which statement about interior finish selection is correct according to flame spread classifications and usage limitations?

a)

Sprinklered buildings may use lower-rated finishes, with Class C allowed in occupied rooms

b)

Sprinklered buildings must use Class A finishes only in all areas

c)

Sprinklered buildings may use higher flame-spread classes, with Class E permitted in corridors

d)

Sprinklered buildings can use any finish class if doors are smoke-proof

93.

A stairwell enclosure in a new 5-storey building must meet which minimum wall rating?

a)

1-hour rating for new buildings ≤4 storeys

b)

2-hour rating for new buildings ≥5 storeys

c)

3-hour rating for any high-rise

d)

No rating if equipped with sprinklers

94.

Which method is acceptable for providing special protection to escalators to limit smoke spread in multi-storey buildings?

a)

Sprinkler-vent method using a water curtain with smoke exhaust

b)

Spray nozzle system forming a dense water spray barrier

c)

Partial enclosures with self-closing fire doors or wired glass

d)

Leaving the escalator open if the building has an alarm system

95.

Which requirement applies when an alarm system is out of service for more than 4 hours?

a)

Notify the Bureau of Fire Protection (BFP) and assign a fire watch

b)

Deactivate sprinklers until the alarm is restored

c)

Lock all manual pull stations to prevent false alarms

d)

Evacuate the building until service is restored

96.

Which control and annunciation feature is mandatory for building fire alarm systems?

a)

Alarm controls located in a central fire command center

b)

Annunciation that identifies the zone or floor of the alarm

c)

Trouble and supervisory signals indicated on the panel

d)

Voice evacuation in all occupancies

97.

Which standpipe provision is correct according to NFPA 14 requirements summarized?

a)

Wet standpipe systems (from basement to top floor) are required in assembly occupancies with >1,000 persons

b)

Dry standpipes are required in hotels taller than two storeys

c)

Standpipes are optional in educational occupancies regardless of height

d)

Standpipes are required only if sprinklers are not present

98.

Select the correct classifications and typical locations for portable fire extinguishers.

a)

Class A: Ordinary combustibles such as wood, paper, cloth; typical in offices and classrooms

b)

Class B: Flammable liquids/gases; typical in kitchens and workshops

c)

Class C: Energized electrical equipment; typical near server rooms and electrical panels

d)

Class K: Cooking oils and fats; typical in commercial kitchens

99.

For distribution of portable fire extinguishers, which placement criterion is explicitly stated?

a)

Place within 1 m from any hazard area

b)

Placement based on hazard and travel distance

c)

Place adjacent to exits only

d)

Place one unit per 50 m² regardless of hazard

100.

Segregation and protection of hazardous processes/storage more dangerous than general occupancy must meet which requirement set? Select all that apply.

a)

Enclose by 4-hr fire-rated construction

b)

Protect by automatic fire suppression

c)

Provide both enclosure and suppression if very high hazard

d)

Use 1-hr construction with self-closing doors only

101.

Which statement best reflects the minimum fire-resistance rating for enclosures of hazardous processes/storage per the section?

a)

1-hour fire-rated with self-closing doors

b)

2-hour fire-rated with self-closing fire doors

c)

3-hour fire-rated without doors

d)

No rating if automatic sprinklers are installed

102.

Smoke control systems are required in certain occupancies. Which set of requirements is accurate for high-rise buildings?

a)

Pressurized stairwells, at least one elevator shaft, zoned smoke control vestibules

b)

Atriums only need natural ventilation; no pressurization

c)

Covered malls require only smoke detection

d)

Underground/windowless facilities never require smoke venting

103.

Elevators in buildings must meet which fire safety criteria? Select all that apply.

a)

Must comply with PMEC

b)

New elevators must meet ASME A17.1 (Firefighters’ Emergency Operations), except in buildings ≤5 stories

c)

Elevators require periodic inspection/testing by building management and BFP

d)

Elevators with Firefighters’ Emergency Operations must be field tested monthly without records

104.

For high-rise buildings, what are the mandated construction and equipment features of the Fire Command Center?

a)

Required for buildings 10 floors or higher, located at the floor of exit discharge, accessible directly from the outside, minimum 2-hour fire-resistive separation, at least 10 m² (min. 1.5 m dimension, 2.4 m ceiling), with emergency voice/alarm, fire department communication unit, fire detection & alarm annunciator, elevator location & operation annunciator, sprinkler valve & water flow panels, and controls for unlocking stairway doors

b)

Required for buildings 6 floors or higher; location optional; 1-hour separation; min. 6 m²; includes only fire alarm panel

c)

Required for any building with elevators; may be inside a tenant space; no separation rating; includes public address system only

d)

Required for buildings 15 floors or higher; located at roof level; 3-hour separation; includes HVAC controls only

105.

In high-rise buildings, smoke control must maintain tolerable smoke levels in protected spaces and ensure accessible egress. Which additional requirement is specifically stated for evacuation and firefighter safety?

a)

Pressurize exterior staircases only

b)

Provide smoke control systems per Sec. 10.2.7.3

c)

Install smoke curtains at all elevator doors

d)

Disable mechanical ventilation during fires

106.

Which statement best describes the sprinkler protection requirement for high-rise buildings?

a)

Install unsupervised sprinklers only in occupied areas

b)

Use approved supervised sprinkler systems per NFPA 13 compliant, covering all areas including concealed spaces

c)

Provide sprinklers only in corridors and lobbies with manual activation

d)

Install sprinklers that operate independently from the Fire Command Center

107.

Select all features required for high-rise sprinkler systems according to the guidance.

a)

Coverage includes closets, concealed spaces, plenums, and areas with combustible materials

b)

Interconnection to the Fire Command Center

c)

Exclusion of areas with ductwork and insulation

d)

Manual-only alarm without supervisory signals

108.

Regarding stairwells in high-rise buildings, which combination aligns with the stated requirements?

a)

Unenclosed stairwells with natural ventilation, doors propped open

b)

Fully enclosed stairwells protected per Division 5, doors kept closed, electronically locked exits auto-unlock during emergencies via FDAS, and interior egress stairwells pressurized

c)

Exterior open stairs with mechanical exhaust and manual door unlocking

d)

Interior stairwells unpressurized to reduce equipment cost

109.

Each floor must have first-aid fire protection. Which configuration matches the specified requirement?

a)

25 mm hose line with spray nozzle connected to wet standpipe and 20 mm supply plus portable extinguishers

b)

38 mm hose line with spray nozzle connected to wet standpipe with 30 mm supply plus portable fire extinguishers

c)

50 mm hose line with fog nozzle connected to dry standpipe with 40 mm supply only

d)

Coiled garden hose connected to potable water and two fire blankets

110.

Which statement reflects the supplementary provisions applicable to high-rise fire protection?

a)

They replace the provisions of RA 9514 and its Implementing Rules and Regulations (IRR)

b)

They are optional unless a local ordinance requires them

c)

They are in addition to all other provisions of RA 9514 and its Implementing Rules and Regulations (IRR)

d)

They apply only to buildings below 10 stories

111.

Identify the correct handling of electronically locked exits in high-rise stairwells during emergencies.

a)

Remain locked to prevent unauthorized access

b)

Auto-unlock via the Fire Detection and Alarm System (FDAS)

c)

Require manual key retrieval from the Fire Command Center

d)

Unlock only after power is restored