1.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 01.Equipment and appliances having an ignition source shall _______________in Group H Occupancies or control areas where open use, handling or dispensing of combustible, flammable or explosive materials occurs.
1. a.not be installed
2. b.be elevated
3. c.be listed as flammable ignition resistant
4. d.be isolated in a separate room
Reference Section(s): 305.2
2.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 02.Appliances having an ignition sources shall be elevated such that the ignition source is not less than ________________ inches above the floor in a private garage.
1. a.12
2. b.18
3. c.6
4. d.30
Reference Section(s): 305.3
3.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 03.Where vehicles are capable of passing under an appliance installed in a public garage, the appliance shall be installed a minimum of ________________ inches higher than the tallest vehicle garage door opening.
1. a.24
2. b.18
3. c.12
4. d.6
Reference Section(s): 305.4
4.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 04.Unless otherwise protected from impact, appliances located in a public garage shall be installed a minimum of ________________ feet above the floor.
1. a.12
2. b.15
3. c.10
4. d.8
Reference Section(s): 305.4
5.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 05.Unless otherwise protected from impact, appliances located in a private garage shall be installed a minimum of ________________ feet above the floor.
1. a.12
2. b.10
3. c.8
4. d.6
Reference Section(s): 305.5
6.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 06.Where the opening dimensions are large enough to allow removal of the largest pieces of equipment installed in an under-floor space, the clear access opening to the under-floor area shall be a minimum of ________________.
1. a.18 inches by 24 inches
2. b.22 inches by 24 inches
3. c.22 inches by 30 inches
4. d.30 inches by 30 inches
Reference Section(s): 306.4
7.
MULTIPLE CHOICE QUESTION
1 min • 1 pt
· 07.Guards are not required for rooftop appliances requiring service where ________________.
1. a.approved fall-restraint devices are installed
2. b.the appliance is at least 8 feet from the roof edge
3. c.the roof slope is less than 3/12
4. d.the roof edge is not greater than 10 feet above grade
Reference Section(s): 306.6, Exception