110 final review 2

110 final review 2

University

19 Qs

quiz-placeholder

Similar activities

Mechatronics Maintenance Specialist Quiz

Mechatronics Maintenance Specialist Quiz

University

15 Qs

CH 36 Week 1 Quiz

CH 36 Week 1 Quiz

University

20 Qs

Introduction to refrigeration 2

Introduction to refrigeration 2

University

14 Qs

Basic Electricity Final Exam CC

Basic Electricity Final Exam CC

University

20 Qs

J194A 2

J194A 2

12th Grade - University

15 Qs

Physics and Its Concepts

Physics and Its Concepts

University

15 Qs

Chapter 10 Agencies

Chapter 10 Agencies

University

20 Qs

Unit 1 Vocab Quiz

Unit 1 Vocab Quiz

10th Grade - University

20 Qs

110 final review 2

110 final review 2

Assessment

Quiz

Physics

University

Medium

Created by

Robert Hemmila

Used 1+ times

FREE Resource

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What is the condition of a relay coil rated to operate on 24 volts if the coil has a resistance of 50 ohms?

Good

Open

Shorted

Grounded

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

If the voltage loss measured across the contacts of a contactor is more than 5% of the line voltage, the contactor __________.

is good

should be replaced

is too large for the application

Has a faulty coil

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What can a technician use to interpret the meaning of the flashing light codes given by the LED on an integrated furnace control board?

Integrated furnace diagnostic module

Diagnostic code legend found on the furnace or online from the manufacturer

Wiring schematic diagram

All of the choices are correct

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following functions is performed by the defrost control during a defrost cycle on a heat pump?

De-energize the outdoor fan motor

Switch the heat pump into the cooling mode of operation by controlling the reversing valve

Energize the supplementary heating

All of the choices are correct

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

What may result if the installation technician does not perform proper and thorough start-up and check procedures on newly installed heating and cooling equipment?

Shortened equipment life

Equipment or structural damage

Inefficient or improper operation

All of the choices are correct

 

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A device used to reverse the flow of refrigerant in a mechanical refrigeration system best describes a ________.

Thermostatic expansion valve

Reversing valve

Check valve

Solenoid valve

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Which of the following choices best represents the common size range, in American Wire Gauge (AWG), of thermostat wire used to make field control wiring connections?

#12 to #16

#18 to #20

#26 to #32

#4 to #8