Unit 33 quiz

Unit 33 quiz

Professional Development

19 Qs

quiz-placeholder

Similar activities

HVAC Recovery EPA 608

HVAC Recovery EPA 608

Professional Development

18 Qs

6035 | Central Heating LO1 Part 2

6035 | Central Heating LO1 Part 2

Professional Development

14 Qs

Phase 2 Exam prep 2

Phase 2 Exam prep 2

Professional Development

20 Qs

Phase 2 Exam prep 1

Phase 2 Exam prep 1

Professional Development

20 Qs

Auxiliary Competency

Auxiliary Competency

Professional Development

20 Qs

Central heating components

Central heating components

Professional Development

20 Qs

6035 Hot Water | LO5

6035 Hot Water | LO5

Professional Development

16 Qs

Radiators and heat emitters level one plumbing

Radiators and heat emitters level one plumbing

Professional Development

14 Qs

Unit 33 quiz

Unit 33 quiz

Assessment

Quiz

Professional Development

Professional Development

Medium

Created by

Robert Hemmila

Used 12+ times

FREE Resource

19 questions

Show all answers

1.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The expansion tank provides a means of removing the air from the system as well as provides ____.

water for the domestic hot water coil

a space for the water expansion and contraction with water temperature changes

a space for excess water from the supply source

All of the above.

2.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A column of water 1 ft high exerts a pressure of ____.

0.277 psig

0.299 psig

0.433 psig

14.696 psig

3.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The more common type of expansion tank is the ____ expansion tank.

compression

standard

restricted

diaphragm-type

4.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

The reason for using zone valves on a hydronic heating system is to ____.

allow different areas of the structure to maintain different temperatures

reduce the chance of a water leak

prevent unused parts of the house from getting warm, and wasting energy

Both a and c.

5.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

Air in a hydronic system can cause ____.

reduced water circulation

increased water concentration

corrosion

Both a and c.

6.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A pressure relief valve is set at 30 psig. The valve is constantly opening and flooding the floor. What is causing the relief valve to constantly open?

The water-regulating valve is broken.

The system is overfiring.

The system needs to be calibrated.

The system requires a new boiler.

7.

MULTIPLE CHOICE QUESTION

30 sec • 1 pt

A high-limit control on a hot water boiler is needed to ____.

regulate the amount of water to each section of baseboard

regulate the water in the supply line to the boiler

balance the water flow rate in the piping system

protect the boiler against excessive water temperatures