1.

A biological indicator is called positive when

a)

the incubation process is complete

b)

there is NO growth in the ampule after incubation

c)

there IS growth in the ampule after incubation

d)

prior to sterilization

2.

to watch, observe, listen to or check over a period of time

a)

record

b)

document

c)

stalk

d)

monitor

3.

record keeping is

a)

fun

b)

mandatory

c)

lame

d)

optional

4.

ultrasonic cleaners use a process called

a)

cavitation

b)

catapult

c)

alkylation

d)

oxidation

5.

documentation of the disinfection process should include

a)

test strip exp date

b)

test strip result

c)

all of these

d)

date

6.

to ensure _____ of the disinfectant, test strips are used

a)

MEC

b)

SAL

c)

TWA

d)

none of these

7.

CI test failure can be caused by (choose all that apply)

a)

Komodo dragons

b)

wrong cycle chosen

c)

incorrect CI used

d)

all of these

8.

the 4 R's

a)

run, read, record, retain

b)

run, read, record, reject

c)

ruin, read, record, retain

d)

run, read, record, refrain

9.

tasks performed by CS techs require specific

a)

time

b)

knowledge and skills

c)

time and temp

d)

work and monitoring

10.

commercially prepared PCD's are currently not available for

a)

EtO

b)

tabletop sterilizers

c)

VHP

d)

H2O2

11.

every load containing implants should be monitored with a PCD containing

a)

a type 5 CI

b)

a BI and a type 5 CI

c)

a BI and a type 6 CI

d)

a BI and a type 4 CI

12.

______ are the most accepted means for providing quality assurance for H2O2 sterilizers

a)

Bowie Dick tests

b)

DUI's

c)

CI's

d)

BI's

13.

how often must room temp and humidity be checked and recorded?

a)

hourly

b)

weekly

c)

daily

d)

every other day

14.

designed to respond with a chemical change to one or more physical conditions

a)

CI

b)

BI

c)

MEC

d)

BUI

15.

internal CI's should be placed

a)

in the least accessible areas

b)

in an incubator

c)

in your shoes

d)

on top of lid

16.

a BI that does not go through the sterilization process

a)

monitor

b)

type 6

c)

control

d)

bacillus atrophaeus

17.

it is important to keep records because

a)

the facility may be involved in a lawsuit

b)

we want support the paper industry

c)

it isn't

d)

the patient may want to see them

18.

why is it important to keep records?

a)

the records could be subpoenaed in a lawsuit

b)

the manager said so

c)

the patient may want them

d)

we don't like trees

19.

processes that should be documented include

a)

sterilization cycles

b)

preventative maintenance

c)

equipment testing

d)

all of these

20.

validation is done by

a)

manufacturers

b)

facilities

c)

biomedical engineering

d)

all of these

21.

in which sterilizer are BI's processed without a PCD?

a)

H2O2

b)

Pre-Vac

c)

EtO

d)

IUSS

22.

monitoring dress codes is

a)

formal monitoring

b)

informal monitoring

c)

official monitoring

d)

unofficial monitoring

23.

Label information on sterilization packages, trays or containers that identifies the sterilizer, cycle run and date of sterilization.

a)

load control number

b)

unit tracking number

c)

julian control data

d)

lot tracking data

24.

DART is a ______ indicator.

a)

Type 1

b)

Type 2

c)

Type 3

d)

Type 4

25.

at least daily

a)

BI test should be run

b)

the cafeteria runs out of fries

c)

autoclaves should be cleaned

d)

Cart washer screens should be cleaned

26.

Continuing _____ records are kept to provide evidence that an employee has kept current and is aware of new best practices.

a)

temperature and humidity

b)

disciplinary

c)

education

d)

felony

27.

A _______ should be run in every sterilizer load that contains an implant.

a)

type 2 CI

b)

BI

c)

type 1 CI

d)

DART

28.

a negative BI proves the load is sterile.

a)

true

b)

false

29.

when using low-level disinfectants it is necessary to document the expiration date of the test strips.

a)

true

b)

false

30.

______ should occur for new employees and those who move to new positions.

a)

formal training

b)

informal training

c)

a fat pay raise

d)

a psyche eval

31.

"Ethylene oxide, hydrogen peroxide gas plasma, and ozone sterilization process do not all need to be monitored using chemical, physical, and biological monitors"

a)

false

b)

true

32.

Before an item can be placed in a liquid chemical sterile processing system it must be

a)

cleaned

b)

heated

c)

sterilized

d)

humiliated

33.

Bowie Dick tests should be run in:

a)

downward displacement sterilizers

b)

Pre-Vac sterilizers

c)

ethylene oxide sterilizers

d)

washer/sterilizers

34.

Laryngoscope blades and anesthesia breathing circuits are examples of______ devices

a)

critical

b)

semi-critical

c)

non-critical

d)

communications

35.

Ethylene Oxide is appropriate for point of use processing because of its long cycle times

a)

true

b)

false

36.

Sterile packages should be stored no lower than 4-8 inches from the floor

a)

true

b)

false

37.

Immediate use sterilization is commonly performed in hospitals

a)

true

b)

false

38.

Wicking materials are used to

a)

allow air removal, steam penetration and facilitate drying

b)

dry instruments before sterilization

c)

allow hydrogen peroxide penetration

d)

aid in the aeration of EtO cycles

39.

Sterilizer recording charts and/or printouts should be checked

a)

by the supervisor at least once a week

b)

by the techs at least once a week

c)

by the tech during and at the end of cycle

d)

by TJC on scheduled audits

40.

Relative humidity is sterile processing should be maintained

a)

between 30% and 60%

b)

between 60% and 65%

c)

above 60%

d)

less 30%