WorksheetsSPT120
Total questions: 40
Worksheet time: 20mins
A biological indicator is called positive when
the incubation process is complete
there is NO growth in the ampule after incubation
there IS growth in the ampule after incubation
prior to sterilization
to watch, observe, listen to or check over a period of time
record
document
stalk
monitor
record keeping is
fun
mandatory
lame
optional
ultrasonic cleaners use a process called
cavitation
catapult
alkylation
oxidation
documentation of the disinfection process should include
test strip exp date
test strip result
all of these
date
to ensure _____ of the disinfectant, test strips are used
MEC
SAL
TWA
none of these
CI test failure can be caused by (choose all that apply)
Komodo dragons
wrong cycle chosen
incorrect CI used
all of these
the 4 R's
run, read, record, retain
run, read, record, reject
ruin, read, record, retain
run, read, record, refrain
tasks performed by CS techs require specific
time
knowledge and skills
time and temp
work and monitoring
commercially prepared PCD's are currently not available for
EtO
tabletop sterilizers
VHP
H2O2
every load containing implants should be monitored with a PCD containing
a type 5 CI
a BI and a type 5 CI
a BI and a type 6 CI
a BI and a type 4 CI
______ are the most accepted means for providing quality assurance for H2O2 sterilizers
Bowie Dick tests
DUI's
CI's
BI's
how often must room temp and humidity be checked and recorded?
hourly
weekly
daily
every other day
designed to respond with a chemical change to one or more physical conditions
CI
BI
MEC
BUI
internal CI's should be placed
in the least accessible areas
in an incubator
in your shoes
on top of lid
a BI that does not go through the sterilization process
monitor
type 6
control
bacillus atrophaeus
it is important to keep records because
the facility may be involved in a lawsuit
we want support the paper industry
it isn't
the patient may want to see them
why is it important to keep records?
the records could be subpoenaed in a lawsuit
the manager said so
the patient may want them
we don't like trees
processes that should be documented include
sterilization cycles
preventative maintenance
equipment testing
all of these
validation is done by
manufacturers
facilities
biomedical engineering
all of these
in which sterilizer are BI's processed without a PCD?
H2O2
Pre-Vac
EtO
IUSS
monitoring dress codes is
formal monitoring
informal monitoring
official monitoring
unofficial monitoring
Label information on sterilization packages, trays or containers that identifies the sterilizer, cycle run and date of sterilization.
load control number
unit tracking number
julian control data
lot tracking data
DART is a ______ indicator.
Type 1
Type 2
Type 3
Type 4
at least daily
BI test should be run
the cafeteria runs out of fries
autoclaves should be cleaned
Cart washer screens should be cleaned
Continuing _____ records are kept to provide evidence that an employee has kept current and is aware of new best practices.
temperature and humidity
disciplinary
education
felony
A _______ should be run in every sterilizer load that contains an implant.
type 2 CI
BI
type 1 CI
DART
a negative BI proves the load is sterile.
true
false
when using low-level disinfectants it is necessary to document the expiration date of the test strips.
true
false
______ should occur for new employees and those who move to new positions.
formal training
informal training
a fat pay raise
a psyche eval
"Ethylene oxide, hydrogen peroxide gas plasma, and ozone sterilization process do not all need to be monitored using chemical, physical, and biological monitors"
false
true
Before an item can be placed in a liquid chemical sterile processing system it must be
cleaned
heated
sterilized
humiliated
Bowie Dick tests should be run in:
downward displacement sterilizers
Pre-Vac sterilizers
ethylene oxide sterilizers
washer/sterilizers
Laryngoscope blades and anesthesia breathing circuits are examples of______ devices
critical
semi-critical
non-critical
communications
Ethylene Oxide is appropriate for point of use processing because of its long cycle times
true
false
Sterile packages should be stored no lower than 4-8 inches from the floor
true
false
Immediate use sterilization is commonly performed in hospitals
true
false
Wicking materials are used to
allow air removal, steam penetration and facilitate drying
dry instruments before sterilization
allow hydrogen peroxide penetration
aid in the aeration of EtO cycles
Sterilizer recording charts and/or printouts should be checked
by the supervisor at least once a week
by the techs at least once a week
by the tech during and at the end of cycle
by TJC on scheduled audits
Relative humidity is sterile processing should be maintained
between 30% and 60%
between 60% and 65%
above 60%
less 30%