WorksheetsRice TransPlanter POST-TEST
Total questions: 20
Worksheet time: 10mins
With ‘Plant pitch adjustment lever’, technician 'A' says that Space between hills can be adjusted. Technician 'B' says, number of seedlings can be adjusted. Who is correct ?
technician 'A'
Technician 'B'
both technician 'A' & technician 'B'
none of them
technician 'A' says that the distance between one row to another row is 20 cm. Technician 'B' says, it is 30 cm. Who is correct ?
Technician 'B'
technician 'A'
both technician 'A' & technician 'B'
none of them
technician 'A' says that with ‘Planting depth’ adjustment, 5 adjustments (shallow to deep) is possible. Technician 'B' says, only 3 adjustments (shallow to deep) is possible. Who is correct ?
technician 'A'
Technician 'B'
both technician 'A' & technician 'B'
none of them
With ‘Seedling quantity adjustments lever’ technician 'A' says that 8 different steps are possible. Technician 'B' says, 9 different steps are possible. Who is correct ?
none of them
both technician 'A' & technician 'B'
Technician 'B'
Technician 'A'
For ‘space between hills’ technician 'A' says that only 3 adjustments (small, medium & large) is possible. Technician 'B' says,only 2 adjustments (small & large) is possible. Who is correct ?
technician 'A'
Technician 'B'
both technician 'A' & technician 'B'
none of them
technician 'A' says that ‘Torque limiter’ is provided to limit the torque of the engine. Technician 'B' says, it is to save Planting unit from damage if it get stuck. Who is correct ?
technician 'B'
Technician 'A'
both technician 'A' & technician 'B'
none of them
With 'L' position of the ‘Plant pitch adjustment lever’, technician 'A' says that the ‘distance between hills’ will be 20 cm. Technician 'B' says, the ‘distance between hills’ will be 200 mm. Who is correct ?
both technician 'A' & technician 'B'
Technician 'A'
technician 'B'
none of them
technician 'A' says that only 2nd gear should be used while ‘transplanting the seedlings’ in field. Technician 'B' says, either 1st gear or 2nd should be used while ‘transplanting the seedlings’ in field. . Who is correct ?
none of them
technician 'B'
Technician 'A'
both technician 'A' & technician 'B'
technician 'A' says that ‘size of nursery cake’ should be 30 cm x 58 cm. Technician 'B' says, 28 cm x 58 cm. Who is correct ?
technician 'B'
Technician 'A'
both technician 'A' & technician 'B'
none of them
technician 'A' says that 8 – 15 cm length of seedlings are called YOUNG seedling. Technician 'B' says that 15 – 25 cm length of seedlings are called MIDDLE seedling. Who is correct ?
both technician 'A' & technician 'B'
technician 'B'
Technician 'A'
none of them
engine oil capacity is being discussed. technician 'A' says it is 0.6 litre. Technician 'B' says it is 0.8 litre. Who is correct ?
Technician 'A'
technician 'B'
both technician 'A' & technician 'B'
none of them
Transmission case (transmission + Hydraulic) oil capacity is being discussed. technician 'A' says it is 2.0 litre. Technician 'B' says it is 0.22 litre. Who is correct ?
none of them
Technician 'A'
technician 'B'
both technician 'A' & technician 'B'
technician 'A' says that Valve Rotator (valve cap) is used for exhaust valve. Technician 'B' says Valve Rotator (valve cap) is used to prevent valve stem digging on rocker arm. Who is correct ?
both technician 'A' & technician 'B'
Technician 'A'
technician 'B'
none of them
Function of ‘Ignition Coil’ is being discussed. technician 'A' says it transforms the low voltage to the thousands of volts. Technician 'B' says that it is one type of transformer. Who is correct ?
both technician 'A' & technician 'B'
Technician 'A'
technician 'B'
none of them
technician 'A' says that there is no liner in this engine. Technician 'B' says that there is direct bore on the crankcase. Who is correct ?
both technician 'A' & technician 'B'
Technician 'A'
technician 'B'
none of them
technician 'A' says that at rated rpm, the speed of the crankshaft inside the engine is 1700 rpm. Technician 'B' says it is 3400 rpm inside the engine. Who is correct ?
technician 'B'
Technician 'A'
both technician 'A' & technician 'B'
none of them
technician 'A' says that the recommended spark plug gap is 0.7 cm. Technician 'B' says that the spark plug gap should be 0.7 mm. Who is correct ?
technician 'B'
Technician 'A'
both technician 'A' & technician 'B'
none of them
technician 'A' says that tappet clearance for Inlet valve is 0.20 mm. Technician 'B' says, tappet clearance for exhaust valve is 0.15 mm. Who is correct ?
none of them
Technician 'A'
technician 'B'
both technician 'A' & technician 'B'
spark plug gap is being discussed. technician 'A' says that spark length (duration) will be less when the gap is less. Technician 'B' says, spark will be too weak when the gap is less. Who is correct ?
technician 'B'
Technician 'A'
both technician 'A' & technician 'B'
none of them
