wayground logo

Free Printable Worksheets

NEW

Font size

S
M
L
XL
Worksheets

Phase 2 Exam prep 1

Total questions: 20

Worksheet time: 15mins

Name
Class
Date
1.

What temperature is 373K in the Celsius scale?

a)

173⁰C

b)

100⁰C

c)

-173⁰C

d)

-200⁰C

2.

The type of non-mechanical backflow prevention used on a domestic washbasin is known as

a)

AUK 1

b)

AUK 2

c)

AUK 3

d)

AUK 4

3.

What is the specific heat capacity for water under atmospheric conditions?

a)

3.14kj/kg/⁰C

b)

4.18kj/kg/⁰C

c)

9.18kj/kg/⁰C

d)

1kj/kg/⁰C

4.

Under Regulation 5 of the Water Regulations, the water undertaker must be informed when which one of the following operations is carried out?

a)

Installation of a bidet without an ascending spray or flexible hose

b)

Installation of a bath with a capacity of fewer than 230 litres

c)

Installation of an RPZ valve to protect against a category 2 fluid

d)

Installation of a pump drawing more than 12 litres per minute

5.

If a hot water appliance has a fault where would you look for guidance?

a)

BSEN 806

b)

Water Regulations

c)

Manufacturer's instructions

d)

Approved Document Part L

6.

Which of the following systems can this appliance be connected to?

a)

Single point water heater

b)

Low pressure system fed from a cold-water storage cistern

c)

Thermal store

d)

Unvented hot water system

7.

An automatic bypass valve is activated by which of the following?

a)

Boiler shutting off

b)

Programmer being switched on

c)

Pressure created within the system

d)

Pressure of the incoming water service

8.

Where should an automatic air vent not be placed?

a)

Highest part of the system

b)

Lowest part of the system

c)

Point where the vent enters the system

d)

Point where the cold feed enters the system

9.

Which port is the cylinder connected to on a mid-position valve

a)

A

b)

B

c)

AB

d)

BA

10.

Condensing boilers are specifically designed to...

a)

Provide stored hot water

b)

Provide hot water at low temeratures

c)

Extract less heat from the flue gases

d)

Extract more heat from the flue gases

11.

Separate space heating zones are created in dwellings when the floor area is greater than

a)

150 m2

b)

180 m2

c)

200 m2

d)

500 m2

12.

Which one of the following Building Regulations discusses the control of heating systems in new-build dwellings?

a)

Part L1a

b)

Part L1b

c)

Part L2a

d)

Part L2b

13.

After disinfection of a cold water system, it is found that the residual chlorine level is 35 ppm. What action should be taken?

a)

The system should be drained and flushed with drinking water

b)

The disinfection process should be repeated to ensure a residual chlorine level of no less than 50 ppm

c)

The system should be flushed with an inhibitor

d)

The disinfection process should be repeated to ensure a residual chlorine level of 70 ppm

14.

Which one of the following mechanical back-flow prevention devices would be used when installing a replacement hose union bib tap?

a)

BA

b)

HUK 1

c)

HA

d)

HC

15.

A kitchen sink relies on what type of air gap between the spillover level and the tap outlet?

a)

AUK 1

b)

AUK 2

c)

AUK 3

d)

AA

16.

Which of the Building Regulations governs the installation of rainwater systems?

a)

Part G

b)

Part H

c)

Part J

d)

Part F

17.

What is the maximum distance allowed from the highest waste connection to the invert of the drain on a stub stack system before ventilation is required?

a)

1.6 m

b)

1.8 m

c)

2.0 m

d)

2.5 m

18.

According to the Water Regulations, what are the maximum flush volumes for a WC?

a)

3 litres short flush and 5 litres long flush

b)

4 litres short flush and 6 litres long flush

c)

9 litres long flush and 6 litres short flush

d)

10 litres long flush and 6 liters short flush

19.

The diagram shows a cross-section of which type of WC pan?

a)

Wash down with double trap

b)

Siphonic with overflow

c)

Washdown with a single trap

d)

Siphonic with a double trap

20.

What is the minimum termination height for the soil stack shown in the diagram?

a)

600 mm

b)

750 mm

c)

800 mm

d)

900 mm