The size indicated for the diameter of copper tubing used for plumbing is the ___.
inside diameter
outside diameter
wall thickness
None of the above.
The size indicated for the diameter of ACR copper tubing is the ___.
inside diameter
outside diameter
wall thickness
None of the above.
The maximum temperature at which soft soldering is done is ___.
212°F
400°F
600°F
842°F
Brazing is done at ___ soldering.
the same temperature as
lower temperatures than
higher temperatures than
temperatures that can be higher or lower than
When soldering or brazing, the solder is ____.
heated directly by the flame of the heat source
heated by the surrounding air
used to oxidize the metal
melted by heat from the tubing and fitting
Molten solder flows between the two base metals being soldered because ____.
the atmospheric pressure pushes it in
of capillary attraction
there are no surface pores in the base metal
the tubing surface melts and the pressure differential forces it in
K-type copper is heavy-duty with a thick tubing wall.
True
False
L-type copper is considered medium weight and is used most frequently.
True
False
M is a lightweight copper and is not commonly used in our industry.
True
False
When tubing is cut with a tubing cutter, a burr is produced in the process. This slight decrease in the inside diameter of the tube can adversely affect the operation of the system.
True
False
When installing a refrigeration system, the piping should be connected with as few joints as possible.
True
False
When soldering, the technician should heat the solder with the torch to allow it to melt.
True
False
An air-acetylene unit usually consists of a B tank of acetylene gas, a regulator, a hose, and a torch.
True
False
ABS and PVC pipe can be used to carry the new blended refrigerants in low temperature applications.
True
False
The copper tubing used in the field piping of refrigeration systems is type (a) .
One reason for insulation on a suction line is to help maintain the proper (a) .
The abbreviation for the plastic pipe used in high pressure systems at low temperature is (a) .
The abbreviation for the plastic pipe that can be used with temperatures up to 180F at 100 psig. It is used for both hot and cold water supply systems is (a) .
When making a swage joint, what should the depth of the enlarged portion of the tube be?
equal diameter of the original tube
less than the diameter of the original tube
more than the diameter of the original tube
none of the above
An operation that causes one end of a copper tube to expand at an angle for flare nut connection to the (a) system.
Operation of heating and cooling tubing to make it softer. (a)
Accomplished at temperatures under 842°F. (a)
Removal of burrs and rough edges from tubing. (a)
Accomplished at temperatures above 842°F. (a)
Caused by excessive bending and straightening of tubing. (a)
Operation that allows two tubes of equal diameter to be joined together. (a)
The best method of leak checking is when the refrigeration system is ____.
in a vacuum
open to the atmosphere
operating with all fans activated
standing with dry nitrogen pressure of 150 psig in the system
When moisture is present in a refrigeration system, it will react with the refrigerant and the oil to form ____.
carbon dioxide
carbon monoxide
carbolic acid
Non-condensable gases ____.
are desirable in a refrigeration system
are undesirable in a refrigeration system
condense readily under normal atmospheric conditions
help in pulling a vacuum
To pull a vacuum means to ____.
lower the pressure in a refrigeration system below atmospheric
raise the pressure in a refrigeration system
allow refrigerant to escape into the atmosphere
condense the gas in the system
A compound gauge ____.
indicates pressures above 14.696 psia
indicates pressures in inches Hg below atmospheric pressure
is one of two gauges on a typical gauge manifold
All of the above.
A micron gauge is used to measure ____.
atmospheric pressures at high altitudes
atmospheric pressures at sea level
absolute pressures below 1 mm Hg
high pressure in a refrigeration system
At what pressure range does the technician valve off the vacuum pump when evacuating to a deep vacuum?
200 to 100 microns.
500 to 200 microns.
300 to 200 microns.
500 to 300 microns.
Which of the following represents the lowest vacuum?
10 psia.
5 in. Hg vacuum.
5 psig.
1000 microns.
A multiple evacuation means that ____.
you connect three vacuum pumps simultaneously to a refrigeration system and pull a vacuum
you pull a vacuum on three different systems at the same time
you pull a vacuum on a refrigeration system more than once, allowing refrigerant or nitrogen into the system between each procedure
there must be more than one system operating before a vacuum can be pulled
Moisture in a liquid state must be ______ before it can be removed with a vacuum pump.
vaporized
condensed
cooled
solidified
To ensure accurate testing, the best material to use for connecting lines to the vacuum pump and gauge set is ____.
light flexible hose
heavy-duty rubber gauge line
copper tube
garden hose
The maximum recommended pressure for leak testing is 150 psig on the low-pressure side of the system.
True
False
Air entering a refrigerant system can eventually lead to compressor failure.
True
False
While under a deep vacuum, any liquid water under the oil in the motor-compressor assembly can be removed by operating the compressor motor for several seconds without any adverse effect on the system.
True
False
After repairing a system that has had an electrical motor failure (compressor burnout), it is good field practice to re-use the recovered refrigerant in that system.
True
False
When using a "standing pressure test" for leak-checking, (a) should never be used since an explosive mixture can be created.
Sludge is produced when moisture, acid, and (a) are present in the system.
There are (a) microns in 1 mm Hg.
A deep vacuum involves reducing the pressure in a refrigeration system to a micron gauge reading of (a) or below.
Why is refrigerant not used for a system standing pressure test?
refrigerant vapor changes pressure too much with temperature change
refrigerant vapor changes acidity too much with temperature change
Why is nitrogen considered a "non-condensable gas"?
nitrogen does not change into a liquid
nitrogen changes into a liquid
A pressure of 100 microns has been reached with the vacuum pump operating. The pump is turned off and the gauge reading rises to 500 microns and stays there. What does this indicate?
The system is leak-tight and moisture free.
The system still has moisture in it.
The system has a leak in it.
none of the above
A pressure of 100 microns has been reached with the vacuum pump operating. The pump is turned off and the gauge reading rises to 5,000 microns and stays there. What does this indicate?
The system still has moisture in it.
The system is leak-tight and moisture free.
The system has a leak in it.
none of the above
A pressure of 100 microns has been reached with the vacuum pump operating. The pump is turned off and the gauge reading rises above 5,000 microns and keeps rising. What does this indicate?
The system has a leak in it.
The system still has moisture in it.
The system is leak-tight and moisture free.
none of the above
How many chlorine atoms does it take to destroy 100,000 ozone molecules in the stratosphere?
a. 1
b. 10
c. 100
d. 1,000
The ______ takes into consideration both the direct and indirect global warming effects of refrigerants.
GWP
GWI
ODP
Which of the following refrigerants is a CFC-type refrigerant?
a. R-22
b. R-123
c. R-134a
d. R-12
Which type of refrigerant has the highest Ozone Depletion Potential (ODP)?
a. HFC
b. HCFC
c. CFC
d. All have the same ODP.
The abbreviation for refrigerants containing chlorine, fluorine, and carbon is ____.
a. HFC
b. HCFC
c. CFC
d. HFAC
As of July 1, 1992, it is illegal to intentionally vent ____ refrigerants into the atmosphere.
CFC
HCFC
Polyvinylether (PVE)
Both a and b
Which of the following is an example of an HCFC refrigerant?
R-12
R-22
R-32
R-134a
Which of the following refrigerants is considered an HFC-type of refrigerant?
R-134a
R-12
R-22
R-11
The abbreviation for refrigerants containing chlorine, fluorine, carbon, and hydrogen is ____.
HFC
HCFC
CFC
HFAC
The abbreviation for refrigerants containing fluorine, carbon, and hydrogen is ____.
HFC
HCFC
CFC
HFAC
Refrigerants that are made up of two or more liquids are called ____.
fluorocarbons
azeotropes
chlorofluorocarbons
isotopes
To process refrigerant to new product specifications is called ____.
recovery
renew
reclaim
recycle
To clean refrigerant by the use of filter dryers is called ____.
recovery
renew
reclaim
recycle
To remove the refrigerant from a system without any testing or processing and to be put back into the same system is called ____.
recovery
renew
reclaim
recycle
Refrigerants that have a low Ozone Depletion Potential (ODP) will, in turn, have a high "Total Equivalent Warming Impact" (TEWI).
True
False
A refrigerant reclaimed from a system may be charged back into the system from which it came.
True
False
The DOT-approved cylinder used for recovering refrigerant is gray and yellow.
True
False
Mechanical refrigerant recovery equipment must meet specifications established by the 1993 AHRI 740 standard.
True
False
Refrigerants that damage the ozone layer contain an element called ________.
hydrogen
sulfur
carbon
The trapping of the Earth's heat in the atmosphere which is causing global warming is called the greenhouse effect.
True
False
Production of CFC refrigerants became illegal on January 1, ________.
2006
1986
2016
The small amount of refrigerant released when removing gauge hoses from the system is called ________.
de maximus releases
none
The DOT-approved cylinder in which refrigerant may be recovered has a mechanism for shutting the recovery system off when it reaches approximately ________% full.
100
90
75
The fastest way to remove refrigerant from a system is to take it out in the ________ state.
vapor
solid
none of the above
Why is stratospheric ozone so important to our environment?
It shields the Earth from ultraviolet (UV-B) radiation.
It shields the Earth from ultraviolet (UV-B) convection.
It shields the Earth from ultraviolet (UV-B) conduction.
None of the above
When did it become illegal to "intentionally" vent CFC refrigerants to the atmosphere? Give the month, day, and year.
July 1, 1992
July 1, 1995
July 1, 1998
July 1, 1991
When did it become illegal to "intentionally" vent HFC refrigerants to the atmosphere? Give the month, day, and year.
November 15, 1995
November 15, 1997
November 15, 1993
November 15, 1996
How are near-azeotropic blends identified?
They are designated as the 400 series refrigerants
They are designated as the 500 series refrigerants
They are designated as the 600 series refrigerants
They are designated as the 200 series refrigerants
On what does universal EPA certification allow a service technician to work?
TYPE I
TYPE II
TYPE III
All of the above
Charging a refrigeration system refers to ____.
removing refrigerant from a system
adding refrigerant to a system
cleaning the refrigerant
vaporizing the refrigerant
Refrigerant in vapor form is normally put into the system through the ____.
liquid line
suction line
hot gas line
liquid return line
When charging a system with vapor refrigerant from a refrigerant cylinder, the cylinder will become ____.
cold
very warm
the same temperature as the ambient air
warm
Refrigerant in liquid form is normally put into the system through the ____.
liquid line
suction line
hot gas line
liquid return line
When charging liquid refrigerant from a single valve supply cylinder, the cylinder is placed ____.
upside down
right side up
on its side
in any position indicated
A graduated cylinder charging device is a device that ____.
measures refrigerant by volume for precise refrigerant charging
has a compensation dial for adjusting for the temperature of the refrigerant
often has a heater to keep the refrigerant temperature from dropping when refrigerant is released into the system
All of the above.
If 22 oz. of refrigerant are to be added to a refrigeration system and the supply cylinder weighs 24 lb. 12 oz. before any is added, what will be the supply cylinder weight after the system has been charged?
23 lb 12 oz
22 lb 12 oz.
23 lb 6 oz.
22 lb 6 oz.
If 30 oz. of refrigerant are to be added to a refrigeration system and the supply cylinder weighs 26 lb. 4 oz. before any is added, what will the supply cylinder weigh after the system has been charged?
22 lb 8 oz.
24 lb 6 oz.
24 lb 8 oz.
22 lb 4 oz.
If a critically charged refrigeration system is overcharged, which of the following is a likely result?
Increased cooling capacity.
Reduced compressor discharge temperature.
Increased system efficiency.
Increased operating pressures.
Fractionation occurs when ____.
some of a blended refrigerant evaporates or condenses before the rest of the blend
when only a fraction of the total charge has been added to a system
the operating pressures of a system increase
Both a and c.
When charging a refrigeration system with a near-azeotropic mixture, what must be done to prevent liquid from entering the system?
Charge only as a vapor through the high side.
Charge only liquid through the high side.
Charge as a liquid through the low side using a restrictor.
Charge as a vapor through the low side using a resistor.
When adding refrigerant in vapor form to an operating refrigeration system, the refrigerant must be added to the low-pressure side of the system.
True
False
When the system pressures are lower than the pressure in the refrigerant tank, such as when the system has just been evacuated or if the system is out of refrigerant, refrigerant can be added to both the high- and low-pressure sides of the system.
True
False
If the tank is a reusable tank, there are no check valves and system refrigerant can enter the tank as long as the system pressure is higher than the pressure in the tank.
True
False
The quickest method to charge a system is to charge only vapor.
True
False
When adding refrigerant in liquid form into the high-side of the system, the system motor/compressor assembly is running.
True
False
Using a restrictor, liquid refrigerant can be charged into the low-side of the system with the system operating.
True
False
One good feature of an electronic charging scale is that it counts upward as refrigerant is removed, to tell the technician how much refrigerant was used.
True
False
A manufacturer's charging chart may be used when available to determine the correct charge for a system.
True
False
Glide is the range of temperatures/pressures in which a blended refrigerant will condense.
True
False
If the pressure in the refrigerant cylinder drops down too low to charge a system (cylinder pressure = low side system pressure), how can the technician increase the cylinder pressure?
Place tank in a bucket of warm water
Place tank in a bucket of ice water
Place tank in a bucket of hot water
none of the above