wayground logo

Free Printable Worksheets

Font size

S
M
L
XL
Worksheets

Quiz on Hot Water Components and Pipe Lengths

Total questions: 44

Worksheet time: 22mins

Name
Class
Date
1.

Domestic immersion heaters are rated at?

a)

3kW

b)

4kW

c)

11kW

d)

10kW

2.

What type of hot water system is this?

a)

A double feed direct system

b)

A single feed indirect system

c)

A double feed indirect system

d)

A single feed direct system

3.

What type of hot water system is this?

a)

Centralised open vented indirect pumped primaries

b)

Indirect system

c)

Centralised unvented indirect gravity system

d)

Modular system

4.

What type of hot water system is this?

a)

A double feed direct system

b)

A single feed indirect system

c)

A double feed indirect system

d)

A single feed direct system

5.

Building Regulations part G now states that?

a)

Stored hot water must never be able to reach 110°C

b)

Stored hot water must never be able to reach 87°C

c)

Stored hot water must never be able to reach 100°C

d)

Stored hot water must never be able to reach 90°C

6.

To prevent Legionella and any waterborne pathogens being present?

a)

Stored hot water temperature must be 60° and above

b)

Stored hot water temperature must be 55° and above

c)

Stored hot water temperature must be 47° and above

d)

Stored hot water temperature must be 90° and above

7.

What type of hot water component is this?

a)

Blending valve

b)

Pressure release valve

c)

Temperature/pressure release valve

d)

Pressure reducing valve

8.

What type of hot water component is this?

a)

Blending valve

b)

Pressure release valve

c)

Temperature/pressure release valve

d)

Pressure reducing valve

9.

What type of hot water component is this?

a)

Tap Stat

b)

Single check valve

c)

Tank connector

d)

Bronze pump

10.

What type of hot water component is this?

a)

Tap Stat

b)

Single check valve

c)

Tank connector

d)

Bronze pump

11.

BS6700 states the maximum length of pipe before it becomes a dead leg?

a)

12mm to 22mm = 16m

b)

12mm to 22mm = 12m

c)

12mm to 22mm = 14m

d)

12mm to 22mm = 18m

12.

BS6700 states the maximum length of pipe before it becomes a dead leg?

a)

22mm to 28mm = 8m

b)

22mm to 28mm = 10m

c)

22mm to 28mm = 12m

d)

22mm to 28mm = 20m

13.

Guidance on the installation procedures for domestic hot water systems can be found in?

a)

Domestic Water Act 2007

b)

Specification of work

c)

Local Authority Regulations

d)

BS6700

14.

The CWSC supplies both the hot and cold water systems. The minimum size of this cistern is?

a)

Equal to 48 hours’ worth of water

b)

230 litres

c)

100 litres

d)

Twice the size of the domestic hot water cylinder

15.

Which appliances is most likely to offer the customer low pressure at a hot water outlet?

a)

Combination boiler

b)

Direct cylinder

c)

Fortic combination hot water unit

d)

Indirect cylinder

16.

What is this item?

a)

Pressure/temperature relief valve

b)

Double check valve

c)

Blending valve

d)

Stop valve

17.

What is the primary function of the open vent on a domestic hot water system?

a)

Take up a hydraulic shunt

b)

Safety relief pipe

c)

To balance the feed from the CWSC

d)

Allow hot water to be distributed at a controlled pressure.

18.

To prevent the risk of legionella forming in a dead leg it should be?

a)

As short as possible

b)

No longer than 2.5 metres, as stated in BS6700

c)

Disinfected annually under a PPM program

d)

Always heated to above 50°C

19.

What type of shower is this?

a)

Instantaneous electric shower

b)

Thermostatic bar mixer type

c)

Gravity fed shower

d)

Bath mixer shower

20.

Identify one advantage of a stored hot water system in a domestic property?

a)

There is a continual supply of hot water

b)

It is cheaper and easier to install

c)

It is suitable for low water pressure areas

d)

It does not require a secondary source of heat.

21.

Which of the following cylinder types is a indirect cylinder?

a)

A.

b)

B.

c)

C.

d)

D.

22.

Which of the following cylinder types is a indirect single feed cylinder?

a)

A.

b)

B.

c)

C.

d)

D.

23.

If a flow switch on a pumped shower does not work, what would be the result?

a)

The water temperature will remain too high

b)

The pump will not be activated by the electrics

c)

The pump will have restrictive water flow

d)

The water temperature will remain too low

24.

Under the Water Regulations, what can category 2 water be described as?

a)

A. Wholesome water

b)

B. Water representing a severe risk to health

c)

C. Wholesome water with its aesthetic qualities impaired

d)

D. Water representing a slight risk to health

25.

When installing an electric shower where should the service valve be located?

a)

As near as possible to the shower unit

b)

On the outlet side of the shower

c)

At least 300 mm from the heater

d)

After the stop valve.

26.

What is the main reason for installing a secondary circulation supply to a hot water tap?

a)

A) To avoid fitting a pump

b)

B) To prevent dead legs

c)

C) To reduce pressure to the taps

d)

D) To improve pressure.

27.

How should the cold feed pipe in a domestic property be sized?

a)

In accordance with your supervisor

b)

In accordance with BS 6700

c)

In accordance with BS 1212

d)

According to the customer’s requirements.

28.

What backflow prevention is required for an over-the-rim bidet without a shower attachment?

a)

A) Double-check valve

b)

B) Single-check valve

c)

C) AUK1 air gap

d)

D) AUK2 air gap

29.

The minimum distance ‘X’ from the cylinder top connection to the vertical open vent pipe is?

a)

250 mm

b)

450 mm

c)

350 mm

d)

150 mm

30.

The pipework arrangement shown is required in order to prevent?

a)

Reverse circulation

b)

Back-siphonage

c)

One pipe circulation

d)

Secondary circulation

31.

The temperature of the hot water from the hot tap can be increased by turning up the?

a)

Room thermostat

b)

Cylinder thermostat

c)

Cold feed valve

d)

Pump setting

32.

What provides the legal requirements for the installation of hot water distribution pipework?

a)

Construction Regulations

b)

Water Regulations

c)

British Standard 6700

d)

Building Regulations

33.

The WRAS provides specific guidance on?

a)

Water Byelaws

b)

Water Regulations

c)

Building Regulations

d)

British Standards

34.

Which one of the following system components is indicated by the British Standard symbol shown?

a)

Float valve

b)

Circulating pump

c)

Pipe reduction

d)

Hot water cylinder

35.

Isolation for an electric shower from the mains supply is normally provided by installing a?

a)

Pull switch outside the room where the shower is installed

b)

Wall mounted switch within reach of the shower

c)

Pull switch inside the room in which the shower is installed

d)

Wall mounted switch in same room out of reach of the shower

36.

Guidance on the requirements for access to hot water pipework is covered by?

a)

BS 8301

b)

BS 6700

c)

BS 1212

d)

BS 1010

37.

Dead legs should be...

a)

15 metres long

b)

As long as possible

c)

10 metres long

d)

As short as possible

38.

What can be fitted to a HWS to prevent dead legs?

a)

Primary circulation

b)

Extra insulation

c)

Secondary circulation

d)

Trace heating

39.

What is A

a)

Thermostat

b)

Breaker fuse

c)

Limit thermostat

d)

re-set button thermostat

40.

Cold pipes should be installed below hot water pipes, why?

a)

Prevents corrosion

b)

Prevents condensation

c)

Prevents heat gain

d)

Prevents heat loss

41.

What type of air gap is required for a sink?

a)

AUK 1

b)

AUK 2

c)

AUK 3

d)

AG

42.

A thermostatic bar mixer must have...

a)

An unbalanced supply

b)

A restricted supply

c)

A balanced supply

d)

Mains fed supply

43.

Brown water coming from hot water outlets fed by a single feed cylinder indicates what?

a)

A build-up of limescale

b)

Loss of the air bubble

c)

A leaking coil

d)

The CWSC needs cleaning.

44.

Excessive hot water at the outlets could mean...?

a)

A build-up of limescale

b)

A faulty thermostat

c)

Too low a flow rate

d)

Air in the system