1.

A building subdrain is located at what level?

a)

Below the level of the public sewer

b)

Above the level of a public sewer

c)

Below the basement floor level

d)

Above the basement floor level

2.

What is the minimum size of fire hose outlet of an interior wet standpipe?

a)

1 inch diameter

b)

1 ¼ in diameter

c)

1 ½ in diameter

d)

¾ in diameter

3.

What is that system of arrangement of venting so installed that one vent will serve two traps?

a)

Relief vent

b)

Unit vent

c)

Common water vent

d)
4.

What is the basic element of a cold water supply in a building?

a)

Downspouts

b)

Subsoil drain lines

c)

Riser run outs

d)

Water closet

5.

Which of the following is NOT a function of all faucets?

a)

Temperature control

b)

Volume control

c)

Level control

d)

On/Off control

6.

What is that controlled outlet in a pipeline used to discharge water or drain of the system?

a)

Blow-off

b)

Dead end

c)

Cleanout

d)

Flush-off

7.

What is the prescribed color coding of piping under Steam Division of a High Pressure pipe?

a)

Black

b)

White

c)

Dirty white

d)

Gray

8.

When heat is applied to water; molecular activity intensified and such particle expand in itself, followed by the change in behavior.

a)

Became abnormal

b)

Increase the volume

c)

Decrease the volume

d)

Became contracted

9.

Pipe materials used inside the buildings and premises shall conform inside the building and premises shall conform to standard specifications set forth this organization?

a)

AWWA

b)

PSC

c)

ASTM

d)

UL

10.

What is that device use to prevent backflow whereby air is admitted to the supply pipe when vacuum occurs?

a)

Gate valve

b)

Air relief valve

c)

Float valve

d)

Vacuum breaker

11.

What do you call that vents for fixtures intended to ventilate the foul odors and remove air from adjacent area?

a)

Local vent

b)

Ventilation pipe

c)

Vapor relief pipe

d)

All of these

12.

The sanitary drainage system for public health reason, must discharge to?

a)

Waterway

b)

Public storm drainage

c)

Public sewer system

d)

Septic tank

13.

A method of installation NOT allowed in a lateral to avoid pressure and retardation of flow of waste water causing deposition of solid is?

a)

Sharp curve

b)

Elbow

c)

Gate valve

d)

Cross-connection

14.

A vent that does not carry liquid or waterborne waste is called?

a)

Wet vent

b)

Dry vent

c)

Local vent

d)

Back vent

15.

A vent which is also serve as a drain is called?

a)

Wet vent

b)

Dry vent

c)

Local vent

d)

Back vent

16.

A bacteria living or active in the absence of free oxygen is called?

a)

Aerobic

b)

Anaerobic

c)

Facultative

d)

All of the above

17.

A secondary pipeline in sewerage a common sewer to which no other sewer is tributary is called?

a)

Interceptor

b)

Lateral

c)

Dead end

d)

Branch

18.

What is that device that operates automatically when refilling the water tank after each discharge and shutting off completely when the tank is already full?

a)

Float valve

b)

Foot valve

c)

Pressure regulating valve

d)

Check valve

19.

What is vertical distance between the dip and crown weir of the trap?

a)

Water trap seal

b)

Air trap seal

c)

Crown weir

d)

Dip

20.

What do you call that process of removing the hardness causing minerals from water?

a)

Water softening

b)

Hardness removal

c)

Demineralization

d)

Dehardnization

21.

Leaching field is categorized as one of the on-site efficient disposal for septic tank. How far should be the minimum distance from shallow well to prevent contamination of water?

a)

25.4 m

b)

1 m

c)

15.2 m

d)

40.2 m

22.

What is the pipe connection in which a ball is held in a cup-like that allows movement in every direction?

a)

Universal joint

b)

Uniform patent

c)

Ball joint

d)

Caulk joint

23.

How is water hardness measured?

a)

Ounce of hardness

b)

Grains per gallon

c)

Parts per million

d)

Soap suds

24.

What is that vent pipe in plumbing that serve the building drain and building sewer?

a)

VSTR

b)

SVTR

c)

Yoke vent

d)

Relief vent

25.

The classification of water when it contains dissolved calcium salts and magnesium?

a)

Soft

b)

Hard

c)

Corrosive

d)

Stain

26.

What is that vent pipe system on plumbing which liquid waste flow through?

a)

Dry vent

b)

Wet vent

c)

Back vent

d)

Stack vent

27.

What is the prescribed distance of vent from trap seal in plumbing installation?

a)

1200 mm

b)

1500 mm

c)

600 mm

d)

300 mm

28.

What is the important advantage of chlorine compared to other water supply treatment?

a)

Control the growth of algae

b)

Effective in the coagulation process

c)

Control taste and odor

d)

Kills bacteria

29.

The difference between a tube and a pipe is that the tube has relatively thin wall and _____.

a)

Straight edge

b)

The listed size correspond to the outside diameter

c)

Relatively square edge

d)

The listed size correspond to the inside diameter

30.

What are the used for disinfections large public water supplies?

a)

Ozone

b)

Sulfur

c)

Chlorine

d)

UV

31.

The jelly like substance being formed in the process of coagulation?

a)

Scum

b)

Sludge

c)

Floe

d)

Alum

32.

The handicapped fixtures are usually designed for people with less physical ability that the general public. For the handicapped, what is the prescribed height of the toilet bowl?

a)

450 mm

b)

400 mm

c)

500 mm

d)

480 mm

33.

What is the pipe fitting with outside thread and projecting square head used for closing the edge of another fitting?

a)

Plug

b)

Cap

c)

Knot

d)

Bushing

34.

What is the process of exposing water in their films to the oxygen of the atmosphere in order to remove neutralize the taste, odor and dissolved oxygen?

a)

Filtration

b)

Screening

c)

Aeration

d)

Sedimentation

35.

What is the type of water closet prescribed for public toilet?

a)

Elongated bowl type

b)

Oval bowl type

c)

Circular bowl type

d)

Egg shape bowl type

36.

What is the process of water supply purification which consists of applying certain chemicals in particles too small to be removed by plain sedimentation?

a)

Coagulation

b)

Sedimentation

c)

Flocculation

d)

Filtration

37.

Size of water piping shall be based on the total __________.

a)

Water consumption

b)

Water demand

c)

Water portability

d)

None of the above

38.

Water closet bowls for ____ use shall be elongated bowl types equipped with open-front seats.

a)

Public

b)

Private

c)

Government

d)

None of the above

39.

Wastewater drain for ____ cupsink at church altar & baptisteries front outlet shall discharge direct to the ground & not connected to any sanitary or drainage system.

a)

Holy sink

b)

Lavatory

c)

Baptismal shrine

d)

Sacrarium

40.

Tunnels shall have the following except

a)

A clear height of 0.6 m above the pipe shall be limited in length to ½ the depth of the trench.

b)

Driven pipes shall have at least one pipe size larger than the pipe to be laid.

c)

Shall be back-filled in thin layers of 0.3 m above the top of the pipe with clean earth which shall not contain stones, boulders, cinders or other materials which can damage or break the pipes or cause corrosive actions.

d)

None of the above

41.

The minimum cross-sectional area at the seat of the control valve or the supply pipe or tubing which feeds the device outlet. If two or more lines supply one outlet, the effective opening shall be the sum of the cross-sectional areas of the individual supply lines of the area or the single outlet, whichever is smaller

a)

Effective opening

b)

Effective depth

c)

Effective area

d)

Effective invert

42.

Suspended cast iron soil pipe shall be supported at not more than ___ m intervals, except that pipe exceeding 1.5 m length may be supported at not more than ___ m intervals. Support shall be adequate to maintain alignment & to prevent sagging & shall be placed within 0.45 of the hub or joint.

a)

1.5 / 3

b)

1.5 / 4

c)

3 / 1.5

d)

4 / 1.5

43.

No water closet or bidet shall be set closer than ___ m from its center to any side of the wall or obstruction or closer than ___ m center to center to any similar fixture.

a)

0.375 / 0.75

b)

0.375 / 0.7

c)

0.4 / 0.7

d)

0.5 / 0.6

44.

Lead pipe shall be supported at by ___ for entire length with hangers properly spaced.

a)

Stiff aluminum or wooden backing

b)

Stiff metal or wooden backing

c)

Stiff plastic or metal sheet

d)

None of the above

45.

Fixtures having concealed slip joint connections shall be provided with an access panel or utility at least ___ m in its least dimension for inspection & repair.

a)

0.30

b)

0.20

c)

0.10

d)

0.40

46.

Excessive water pressure – water pressure greater than ___ Kpa.

a)

551

b)

552

c)

553

d)

554

47.

Drains shall have a waterway equivalent area of the “tailpiece” – meaning, the sum of all areas of the perforation of the strainer is

a)

Strainers serving bathtub

b)

Strainers serving shower

c)

Strainer serving lavatory

d)

None of the above

48.

Copper tubing shall be supported at approximately ___ m intervals for piping 38 mm diameter & smaller & ___ m intervals for piping 51 mm & larger in dia.

a)

1.8 / 3.0

b)

1.9 / 3.5

c)

1.5 / 2.5

d)

None of the above

49.

Continuous waste fixture tailpiece connections were exposed or accessible may be of seamless drawn brass not less than Ga. 20 B & S or ___ mm thk.

a)

0.90

b)

0.80

c)

0.70

d)

0.60

50.

All porcelain enamel surfaces on plumbing fixtures shall be ____.

a)

Mold resistant

b)

Acid resistant

c)

Corrosion resistant

d)

None of the above

51.

All pipe determinations shall be based on eighty percent (___) the reduced pressure.

a)

70%

b)

60%

c)

80%

d)

90%

52.

Must be supported at least every other point except that when the developed length between supports exceeds 1.2 m, that shall be provided at each joint.

a)

Couplings and compression joints

b)

Hubless or compression gasket joints

c)

Caps and plugs

d)

None of the above

53.

Shall be supported by stiff metal or wood backing with hangers in its entire length for small size tubings up to 38 mm dia. & without backings but with spaced metal hangers at approved spacing for larger-size tubing.

a)

Steel tube

b)

Plastic tube

c)

Aluminum tube

d)

Concrete tube

54.

Maximum length of supply piping in meters.

a)

61

b)

62

c)

63

d)

64

55.

If water closets or other plumbing fixtures are installed in the buildings where there is no sewer within a reasonable distance, suitable provision shall be made for disposing of the building sewage by some accepted method of sewage treatment and disposal, such as;

a)

Waste tank

b)

Septic tank

c)

Sewage disposal system

d)

None of the above

56.

Drainage pipes shall be run in practical alignments and at a uniform slope between manholes of not less than ___ toward the point of disposal.

a)

20 mm / m or 2%

b)

30 mm / m or 3%

c)

40 mm / m or 4%

d)

10 mm / m or 1%

57.

Changes in direction of piping shall be made by the use of approved pipe fittings & shall be the angles presented by the following except

a)

22 ½ degrees bend

b)

45 degrees bend

c)

60 degrees bend or other approved fittings of longer sweeps

d)

30 degrees bend

58.

All piping of plumbing systems shall be of durable ____ approved materials free from workmanship, designed and constructed by Registered Master Plumber to ensure satisfactory service.

a)

NAMPAP

b)

DILG

c)

DPWH

d)

DENR

59.

A physical separation, which may be a low inlet into the indirect waste receptor from the fixture, appliance or device indirectly connected

a)

air separation

b)

air break

c)

Air divisor

d)

None of the above

60.

A length of soil or waste stack corresponding in the general to a storey height, but in no case less than 2.43 m within which the horizontal branches from one floor or storey of a building are connected to the stack.

a)

Branch interval

b)

Interval

c)

Branch

d)

Length

61.

Each family dwelling unit on premises abutting on a sewer or with a private sewer disposal system shall have at least ___ water closet and ___ kitchen type sink.

a)

1 , 2

b)

1 , 1

c)

2 , 1

d)

2 , 3

62.

al system shall have at least ___ water closet and ___ kitchen type sink.

a)

1 , 2

b)

1 , 1

c)

2 , 1

d)

2 , 3

63.

Horizontal drainage lines connecting to a vertical stack shall enter through the following except:

a)

45 wye branches

b)

Combination wye & 1/8 bend branches

c)

Or other approved fittings of longer sweeps

d)

30 wye bend

64.

Horizontal drainage lines connecting to other horizontal drainage lines shall enter through the following given below except:

a)

45 wye branches

b)

Combination wye & 1/8 bend branches

c)

Or other approved fittings of longer sweeps

d)

30 wye bend

65.

Birth of plumbing profession in the Philippines.

a)

Intramuros

b)

Barasoain

c)

Bataan

d)

Cebu

66.

Vertical drainage lines connecting to other horizontal drainage line shall enter through?

a)

45 wye branches

b)

Or other approved fittings of longer sweeps

c)

60 degree branches or effects (only for pipes installed in the vertical position

d)

45 degree branches

67.

No drainage fitting shall use:

a)

Double hub fitting for leak-caulked joint in vertical position

b)

Single or double tee branch

c)

Side inlet quarter bend, running thread, band or saddle

d)

All of the above

68.

May be used on vertical lines as a fixture connection. (approved stainless steel bands with neoprene gaskets for jointing hubless cast iron soil pipes are acceptable for use).

a)

Single hub sanitary tapped tee

b)

Double hub sanitary tapped tee

c)

Triple hub sanitary tapped tee

d)

None of the above

69.

A minimum standard quantity of plumbing fixtures that discharges waste into a plumbing installation.

a)

Plumbing unit

b)

Plumbing fixtures

c)

Plumbing system

d)

Plumbing minimum

70.

In prohibited fitting and practices under this rule no ____ shall be threaded.

a)

G.I soil pipe

b)

Cast iron soil pipe

c)

Pvc soil pipe

d)

None of the above

71.

Further, a ____ and bathtubs or shower shall be installed to meet the basic requirements of sanitation and personal hygiene.

a)

Sink

b)

Lavatory

c)

Basin

d)

None of the above

72.

Fixture directly connected to the drainage system shall be equipped with a ____.

a)

Ventilating system

b)

Water sealed trap

c)

Soil pipes

d)

Waste pipes

73.

Any such pipe or piping ____ mm or larger in diameter may have a slope of 10 mm / m or 1 % provided it is approved by Administrative Authority.

a)

100 mm

b)

102 mm

c)

101 mm

d)

104 mm

74.

Water pipes & fittings with a lead content that exceed ____ shall be prohibited & shall not be used in potable piping systems.

a)

8%

b)

9%

c)

10%

d)

11%

75.

Water closet & urinal tanks shall be equipped with a listed ____ & shall be installed with the critical level at least 25 mm above the full opening of the overflow pipe.

a)

Corporation cock

b)

Gate valve

c)

Ball cock

d)

None of the above

76.

The total numbers of set of sanitary / plumbing plans required by the building official when applying for permit are;

a)

4

b)

5

c)

3

d)

6

77.

The sanitary and plumbing permit will be revoke if the project has been abandoned or suspended for how many days?

a)

120

b)

60

c)

30

d)

100

78.

The quantity of water required to be supplied to every plumbing fixture shall be represented by ____.

a)

Fixture units

b)

Fixture drain fd

c)

Fixture trap ft

d)

None of the above

79.

The minimum air gap for effective openings not greater than 25 mm in diameter affected by walls.

a)

2 times diameter of effective opening

b)

4 times diameter of effective opening

c)

5 times diameter of effective opening

d)

3 times diameter of effective opening

80.

The minimum air gap for effective openings not greater than 25 mm in diameter not affected by walls.

a)

3 times diameter of effective opening

b)

2 times diameter of effective opening

c)

4 times diameter of effective opening

d)

5 times diameter of effective opening

81.

The maximum height required from finished grade line the Siamese inlet connection of a stand pipe.

a)

2.0 m

b)

1.2 m

c)

1.5 m

d)

2.5 m

82.

The minimum air gap for over rim bath filters & other fixtures with effective openings not greater than 25 mm in diameter affected by walls.

a)

76 mm

b)

77 mm

c)

78 mm

d)

79 mm

83.

The minimum air gap for over rim bath filters & other fixtures with effective openings not greater than 25 mm in diameter not affected by walls.

a)

54 mm

b)

53 mm

c)

52 mm

d)

51 mm

84.

The minimum air gap for lavatories & other fixtures with effective openings not greater than 13 mm in diameter if not affected by wall.

a)

25

b)

24

c)

23

d)

22

85.

The minimum air gap for lavatories & other fixtures with effective openings not greater than 13 mm in diameter if affected by wall.

a)

36 mm

b)

37 mm

c)

38 mm

d)

39 mm

86.

The minimum air gap for sink, laundry trays, goosenecks bath faucets & other fixtures with effective openings not greater than 19 mm in diameter if not affected by wall.

a)

40 mm

b)

39 mm

c)

38 mm

d)

37 mm

87.

The minimum air gap for sinks, laundry trays, gooseneck bath faucets & other fixtures with effective openings not greater than 19 mm in diameter if affected by wall.

a)

56 mm

b)

57 mm

c)

58 mm

d)

59 mm

88.

The expiration of the permit for sanitary / plumbing will be expired after how many years from the date of issuance?

a)

2

b)

1

c)

1.5

d)

3

89.

The drawings, specification, calculations and etc for plumbing / sanitary permit will be signed by a registered and licensed,

a)

Drainage engineer

b)

Master plumber

c)

Sanitary engineer

d)

Architect

90.

Restaurant kitchen & other special-use sink may be made of approved-type sheet steel not less than Ga. 16 U.S B & S or 1.6 mm thick.

a)

Bonderized & galvanized

b)

Aluminum

c)

Steel

d)

None of the above

91.

No urinal shall be set closer than ____ m center to center

a)

0.70

b)

0.60

c)

0.50

d)

0.65

92.

No building sewer or other drainage pipings or part thereof, constructed of materials other than that approved for use under or within the building shall be installed under or within ____ m of any building or structure, nor less than 0.3 m below the finished ground surface.

a)

0.60

b)

0.50

c)

0.30

d)

0.20

93.

The building shall be installed under or within ____ m of any building or structure, nor less than 0.3 m below the finished ground surface.

a)

0.60

b)

0.50

c)

0.30

d)

0.20

94.

No building water service pipe shall be less than ____ mm in diameter.

a)

21

b)

20

c)

25

d)

19

95.

Inadequate water pressure – water pressure less than ____ kPa.

a)

103

b)

104

c)

105

d)

106

96.

In screwed pipe – IPS shall be supported at approximately ____ m intervals for piping 19 mm diameter & smaller & ____ m intervals for piping 25 mm & larger in diameter.

a)

3.5 / 3.0

b)

3.0 / 3.5

c)

3.6 / 3.0

d)

3.0 / 3.6

97.

In ground-piping buried on the ground shall be laid on the ____ for its entire length, except where concrete support is provided which is adequate & approved by the Administrative Authority.

a)

Firm bed

b)

Strata

c)

Compacted earth

d)

None of the above

98.

For excreta drainage system, no vitrified clay pipes or fittings for building drain or sewer shall be used above ground or whenever piping is pressurized by a pump or ejector. They shall be kept ____ m below finish ground level.

a)

0.30

b)

0.40

c)

0.50

d)

0.60

99.

For excreta drainage system, no galvanized wrought iron or galvanized steel pipe shall be used underground & shall be kept at least ____ mm above ground.

a)

155

b)

152

c)

153

d)

154

100.

For vertical piping, screwed pipe - iron pipe size (IPS) shall be supported at not less than every other storey.

a)

Drift

b)

Height

c)

Level

d)

Dimension

101.

For vertical piping, ____ shall be supported at each storey or at a maximum interval of 3 m o.c.

a)

Lead tubing

b)

Copper tubing

c)

Steel tubing

d)

G.I tubing

102.

For vertical piping, cast iron pipes – Bell & Spigot & hubless pipe shall be supported at ____ or closer.

a)

Every 2 storey

b)

Every storey

c)

Every 3 storey

d)

Every 4 storey

103.

For the set of sanitary / plumbing plans required by the building official when applying for permit, how many set/s of drawing will be returned on the applicant?

a)

1

b)

2

c)

3

d)

4

104.

For the set of sanitary / plumbing plans required by the building official when applying for permit, how many sets/s of drawing will be provided for the administration authority?

a)

1

b)

4

c)

3

d)

2

105.

Fixture unit Lawn Sprinkler (standard type, each head).

a)

1

b)

2

c)

1.5

d)

2.0

106.

Fixture unit Water closet (economical flush) private use.

a)

5

b)

4

c)

3

d)

2.5

107.

Which of the following types of traps allowed?

a)

Traps which depend upon moving parts to maintain a seal

b)

P-traps

c)

Crown vented trap

d)

Bell traps

108.

Fixture unit of Urinal (stall & wall).

a)

5

b)

4

c)

3

d)

2

109.

Fixture unit of Urinal (pedestal or similar type).

a)

10

b)

15

c)

12

d)

9

110.

Fixture unit of Urinal (flush tank).

a)

2

b)

3

c)

4

d)

5

111.

Fixture unit of Water Closet (flush tank & flushometer tank), hose bibb or sill cock (standard type) private use.

a)

2

b)

3

c)

4

d)

5

112.

Fixture unit of Water Closet (flush tank & flushometer tank), hose bibb or sill cock (standard type) public use.

a)

5

b)

4

c)

3

d)

2

113.

Fixture unit of Water Closet (economical flush) public use.

a)

5

b)

4

c)

3

d)

2

114.

Fixture unit of Mobile Home (each) – temporary facilities.

a)

5

b)

6

c)

7

d)

8

115.

Fixture unit of Bidet, bathtub (with or without shower over), laundry tub or clothes washer (each pair of faucets), shower (each head), sink or dishwasher private use.

a)

2

b)

3

c)

4

d)

5

116.

Fixture unit of Bidet, bathtub (with or without shower over), laundry tub or clothes washer (each pair of faucets), shower (each head), sink or dishwasher public use.

a)

2

b)

3

c)

4

d)

5

117.

Fixture unit Bar sink, drinking fountain, lavatory private use.

a)

1

b)

2

c)

1.5

d)

2.5

118.

Fixture unit Bar sink, drinking fountain, lavatory public use.

a)

1

b)

2

c)

1.5

d)

2.5

119.

In excreta drainage system, what piping installations shall be used in high rise buildings?

a)

ABS Acrylonitrile-Butadiene-Styrene

b)

PVC (Polyvinyl Chloride)

c)

Vitrified clay pipe

d)

ABS Acrylonitrile-Butadiene-Styrene & PVC (Polyvinyl Chloride)

120.

Consists of two (2) independently acting internally or externally loaded check valves, four (4) properly located test cocks with connectors & two (2) isolation gate valves.

a)

Atmospheric vacuum breaker (avb)

b)

Double check valve backflow prevention assembly

c)

Pressure vacuum breaker backflow prevention assembly

d)

None of the above

121.

Consists of two (2) independently acting internally loaded check valves, differential pressure relief valve, four (4) properly located test cocks & two (2) isolation gate valves.

a)

Pressure vacuum breaker backflow prevention assembly

b)

Reduced pressure principle backflow prevention assembly

c)

Atmospheric vacuum breaker (avb)

d)

Double check valve backflow prevention assembly

122.

Consists of a loaded air inlet valve, an internally loaded check valve, two (2) properly located test cocks & two (2) isolation gate valves.

a)

Atmospheric vacuum breaker (avb)

b)

Double check valve backflow prevention assembly

c)

Pressure vacuum breaker backflow prevention assembly

d)

None of the above

123.

Consist of a body, a checking member & an atmospheric opening.

a)

Atmospheric vacuum breaker (avb)

b)

Double check valve backflow prevention assembly

c)

Pressure vacuum breaker backflow prevention assembly

d)

None of the above

124.

All pipings passing under or through walls shall be protected from breakage with embedded ____.

a)

Concrete pipe metal sleeves

b)

PVC pipe sleeves

c)

Metal pipe sleeves

d)

None of the above

125.

All pipes passing through or under cinders or other corrosive materials shall be protected from external corrosion by encasing same with ____ or in any other approved manner.

a)

Metal sheath

b)

Polybutane sheath

c)

Polyethylene sheath

d)

Plastic sheath