Font size
WorksheetsMP F1 SP3
Total questions: 109
Worksheet time: 55mins
Plumbing permit shall be invalid if works not commenced after a period of,
120 days
1 year
2 years
360 days
Efficient but moderately noisy and its reasonably low cost. Most of the bowl surface is covered with water.
Wash down
Reverse trap
Siphon jet
Siphon vortex
Expensive, flushing is very noisy and large water surface and large trap way size make this model efficient and suitable for commercial use.
Reverse trap
Pressure/tankless
Pressure/tank
Siphon jet
Least efficient, most noisy type but lowest in cost.
Wash down
Reverse trap
Siphon jet
Siphon vortex
Model is mostly of one piece construction with low profile, expensive and the large water surface provides a very efficient and clean process and the flushing is extremely quiet.
Siphon jet
Siphon vortex
Reverse trap
Wash down
Quiet flushing, have moderate cost and most popular residential model.
Siphon jet
Siphon wash down
Siphon vortex
Reverse trap
What type of material used for the base of a septic tank.
Mass concrete
Reinforced concrete
Earth base
Light weight concrete
When water comes out as soon as the fire sprinkler is activated, the system is.
Wet standpipe
Dry standpipe
Pre-action
Deluge
What is used to unclog a toilet?
Hand auger
Closet auger
Straight auger
Darsho’s auger
The date when Sanitation Code is issued.
August 22, 1991
May 25, 1973
June 27, 1956
August 22, 1955
Provincial Water Utilities Act.
RA 1378
PD 198
PD 1152
PD 1067
Is a receptacle used to catch surface drained from cemented courts, driveways, and yards.
Yard Catch Basin
Yard Drain
Garage Catch Basin
Exterior Basin
The date when the Philippine Environment Code is signed.
August 20, 1971
May 25, 1973
June 6, 1977
June 22, 1975
What is the maximum number of fixture units that may be connected to a 75 mm diameter house drain pipe under 4% slope?
18
21
25
34
A piping arrangement in which a drain from a fixture, appliance, or device discharge indirectly into a fixture, receptacle, or interceptor at a point below the flood level rim of the receptacle so installed as to prevent backflow or siphonage.
Air break
Pressure
Air stop
Air gap
Consists of a running trap installed under the basement floor to protect it from freezing.
Floor drain
Oversize house drain
Area drain
Floor basin
What is the slope of a 100 mm diameter house drainpipe with 100 fixture units?
2%
3%
4%
5%
The following back of used, contaminated or polluted water from plumbing or vessel into a water supply pipe due to negative pressure in such pipe.
Backflow connection
Back-siphonage
Back pressure backflow
Back-vent pipe
The house drain should be sized correctly to have a flow of about of the pipe diameter.
45%
50%
55%
60%
Environment Code of the Philippines.
RA 1378
PD 196
PD 1152
PD 1067
What is the slope of a 100 mm diameter house drain pipe with 114 fixture units?
2%
3%
4%
5%
What is the slope of a 125 mm diameter house drain pipe with 203 fixture units?
2%
3%
4%
5%
The date when the Provincial Water Utilities Act is signed.
August 22, 1991
May 25, 1973
June 27, 1970
August 22, 1955
Fixture unit value of a Public or Hotel Sink.
1
1.5
2
3
It is not preferred to discharge into the septic tank.
Combined drain
Storm drain
Industrial drain
Sanitary drain
Water Code of the Philippines.
RA 1378
PD 198
PD 1152
PD 1067
It is a receptacle used to receive water to be drained from the floor into the plumbing system.
House drain
Oversize house drain
Floor drain
Catch basin
What is the maximum number of fixture units that may be connected to a 75 mm diameter house drain pipe under 2% slope?
18
21
25
34
A type of pipe connection in which a ball-shaped end is held in a cuplike shell and allows movement in any direction.
Ball valve
Ball cock
Ball joint
Ball cup
What is the maximum number of fixture units that may be connected to a 125 mm diameter house drain pipe under 3% slope?
162
216
264
275
A sink designed primarily to receive wastes from bedpans and having a flush rim, an integral trap with a visible trap seal, and the same flushing and cleansing characteristics as a water closet.
Blow-off sink
Hotel sink
Clinic sink
Sanitary sink
It is adopted when the street drainage is higher in elevation than the basement floor of the building.
Overhead storm drain
Outside storm drain
Overhead feed drain
Inside storm drain
Sanitary sewage is also known as,
Soil
Plumbing waste
Domestic sewage
Pipe sewage
Fixture unit value of 1 bathroom consisting of 1 water closet, lavatory, bathtub and overhead shower or water closet, lavatory and shower compartment.
3
5
6
8
Civil Code of the Philippines.
RA 1378
RA 1364
RA 386
PD 1067
The unobstructed vertical distance through the free atmosphere between the outlet of water pipe and the flood level rim of the receptacle into which it is discharging.
Air break
Pressure gap
Air stop
Air gap
What is the slope of a 125 mm diameter house drain pipe with 150 fixture units?
2%
3%
4%
5%
A device or means to prevent flow of liquid from returning to source of supply and also called vacuum breaker.
Backwater valve
Back-siphonage
Backflow preventer
Back-vent preventer pipe
A device installed in a drainage system to prevent reverse flow.
Backwater valve
Back-siphonage
Backflow preventer
Back-vent pipe
Appropriate fittings for a storm drain.
Wye, 1/8 bend, long radius
Tee, 1/8 bend, long radius
Wye, 1/4 bend, long radius
Wye, 1/8 bend, short radius
The date when the Water Code is signed.
December 20, 1971
May 25, 1973
May 25, 1975
December 31, 1976
The most preferred type of back flow valve because it has the characteristics of noninterferences in the movement of air inside the drainage system.
Interference valve
Unbalanced valve
Non-interference valve
Balance valve
Reduces the action scouring in the pipe, thus the solid waste are carried along the bottom of the pipe.
Undersize house sewer
Oversize house drain
Domestic sewage drain
Sanitary sewer
Storm drain is installed provided a slope of not more than per meter run.
0.5 %
1%
1.5%
2%
It occurs due to an increased reverse pressure above the supply pressure.
Back pressure backflow
Back-vent pipe
Backflow connection
Back pressure siphonage
It is a device installed in a house drain immediately inside the foundation wall of the building.
Soil trap
Main trap
House trap
Sewer trap
It is also known as the collection line of a plumbing system.
House drain
Soil drain
Waste drain
Main drain
A room equipped with a shower stall or bathtub.
Bathroom group
Bathroom
Shower room
Half bathroom
Fixture unit value for every 15 sq. foot of roof drain.
1
1.5
2
3
An act to regulate the trade of Master Plumber in the Philippines.
RA 1378
RA 1364
RA 1478
PD 1067
Sanitation Code of the Philippines.
PD 1378
PD 856
PD 857
PD 568
A loop of pipe rising approximately 35 feet, at its top most point above the highest fixture it supplies.
Sanitary loop
Plumbing loop
Barometric loop
Manometric loop
Is a device used in kitchen serving hotels, dining rooms, clubhouses and restaurants.
Grease basin
Grease interceptor
Oil interceptor
Oil catch basin
Fixture unit value of a Shower Bath.
1
1.5
2
3
A condition or any arrangement whereby reverse flow can occur.
Backflow connection
Back-siphonage
Back pressure backflow
Backflow pipe
Revised Fire Code of the Philippines 2008.
RA 9514
RA 1364
RA 386
PD 1182
It is sometimes located under the basement floor or when the walls of the buildings.
Overhead storm drain
Outside storm drain
Splash pan
Inside storm drain
Clean Water Act.
RA 8749
RA 9275
PD 1067
PD 198
Clean Air Act.
RA 8749
RA 9275
PD 1067
PD 198
Clean Air Act
RA 8749
RA 9275
PD 1067
PD 198
An act to regulate the practice of Sanitary Engineering in the Philippines.
RA 1378
RA 1364
RA 386
PD 1067
A part of the vent line, which connects directly with an individual trap underneath or behind the fixture and extends to the branch or main vent pipe at any point higher than fixture or fixture traps it serves.
Back-vent pipe
Circuit vent pipe
Yoke vent pipe
Loop vent
The date when the Sanitary Engineering Law and Plumbing Law are approved.
A. January 18, 1955
B. June 18, 1955
C. June 27, 1956
D. September 16, 1955
It collects water coming from the downspout leading the accumulated water away from the house at a relatively low rate of flow.
Overhead storm drain
Roof leader
Catch basin
Splash pan
Not preferred type of backflow valve because of its poor performance
Interference valve
Non-interference valve
Unbalanced valve
Balance valves
Civil Code of the Philippines.
RA 386
PD 1152
RA 9514
PD 856
Grease can be disposed in the kitchen sink?
Always
Never
Sometimes
Not sure
Your toilet should be running all the time?
Always
Never
Sometimes
Not sure
Teflon tape can be used when leaking occurs at which location.
Tub Spout
Shower Valve
Drain
Shower Head
Where is the cold water valve located?
Left side
Right side
center
bottom
What do all toilets have built into them?
Anti-siphon valve
P-trap
TP valve
Water
What can never be re-used when replacing toilet?
Tissue
Flange Bolts
Wax Rings
Water
What fits between a closet flange and toilet bowl?
O-ring
Wax Ring
Bolt Ring
Flange Ring
What type of adhesive is used to caulk around wet surfaces?
Elmers glue
Silicone
Rugby
Non-sag A
The safety valve on a water heater is called what?
Drain valve
Angle valve
TP valve
Gate valve
A faucet with a pullout spout, sometimes called a?
easy-touch
magic-touch
one-touch
sensorized
How many single compartment fixtures of sinks, lavatory or laundry tubs that can be connected to a single trap?
2
3
4
5
What is the proper way to wind a Teflon on a pipe thread?
clockwise with the pipe facing you
counter-clockwise with the pipe facing you
clockwise with the pipe facing the traverse side
none of the above
A water treatment processes designed to destroy disease-causing microorganisms. Is often assessed by measuring the coliform group of indicator organisms.
Chlorination
Disinfection
Detoxification
Dissolution
Caulk joint shall be firmly packed with oakum or hemp and powered received with pure load what that depth of lead over oakum?
25 mm (1”)
32 mm (1 ¼”)
38 mm (1 ½”)
13 mm (½”)
A vertical enclosure with a removable cover providing access to a curb cock.
Shutoff valve
Curb box
Corporation stop
Manhole
A type of nipple having both ends externally threaded and the midsection unthreaded.
nipple
open nipple
shoulder nipple
tapped nipple
Vertical installation of double sanitary tees maybe used when the barrel of the fitting is at least than the largest side inlet.
1 pipe size larger
2 pipe size larger
3 pipe size larger
None of the above
The vertical distance from the centerline of the pump (this would be the shaft on a horizontal pump) to the level in the discharge vessel.
Discharge head
Suction head
Suction lift
Pressure head
A type of material made from mild steel that is drawn through a die and welded. It is dipped in bath of zinc, which treatment serves to some degree the pipe against the effect of acids.
Galvanized steel pipe
Galvanized wrought iron pipe
Cast iron pipe
Acid resistance cast iron pipe
A fitting with a projecting collar along the edge used on installation requiring increased area coverage for added mechanical strength.
Union
Flange
Union
Bushing
A form extracted metallurgy, its main use is to produce iron from ore.
Tuberculation
Carbonation
Smelting
Coagulation
Assuming the waste pipe of a fixture is 50 mm, what should be the size of its vent pipe?
32 mm
25 mm
38 mm
50 mm
A cast iron pipe in which the carbon is reformed by magnesium inoculation, resulting in a material having high strength without otherwise changing its basic properties. Good corrosion resistance makes this type of pipe especially useful in underground installations.
Acid Resistance Cast Iron Pipe
Galvanize Steel Pipes
Galvanize Wrought Iron Pipe
Ductile Iron Pipe
How many gallons do an average daily consumption of a Bathtub?
5 gallons
30 gallons
40 gallons
100 gallons
Can be constructed with hand tools or power tools-depth of about 15 meters (50 ft)-can have the greatest diameter that a space may allow.
Dug well
Drive well
Bored well
Deep well
A device used to control an incoming high water pressure into the water distribution system by mechanical means so as to bring it to a working pressure of 80 psi.
Pressure relief valve
Pressure reducer
Pressure reducing valve
Pressure regulator
A residence with 12 family members requires 3.6 cu. meters of cold water daily with peak demand. What is the maximum hot water probable hourly demand?
110 liters
100 liters
120 liters
140 liters
A term used for a pipe extension of not more than 2 feet in length, installed at any stack or branch of plumbing rough-in for the purpose future tap.
tail piece
Branch
clean out
stub out
A type of water pump with its pump motor installed on the surface attached to a lift and push rod to activate a submerged piston.
reciprocating pump
sump pump
jack pump
centrifugal pump
A vent used in a battery of plumbing fixtures where the vent is installed in front of the last fixture of the battery.
yoke vent
circuit vent
stack vent
relief vent
In a water distribution system, locations such as supply pipe to every water heater requires a full open valve. Which of the following in the list is a full open valve?
check valve
ball valves
globe valve
angle valve
Minimum water delivery in liters per minute for an outlet of a wet standpipe at a residual pressure or 1.8 kilos per sq. mts.
132 liters per minute
112 liters per minute
155 liters per minute
126 liters per minute
Single lever valves used in kitchen sink and lavatory faucets or at shower valves has gain popularity in plumbing installation today. This is because these valves are beautiful and are maintenance-free. These valves work by the principle of a:
gate valve
angle valve
ball valve
globe valve
The maximum height of a fire service connection from the grade line is cms.
120 cms.
130 cms.
122 cms
102 cms.
The maximum horizontal developed length between the trap seal and the vertical vent inlet at the trap arm.
6 feet
5 feet
4 feet
3 feet
The minimum height of fire service connection from the grade line is cms.
50 cms.
100 cms.
46 cms.
35 cms.
The standard size of an outlet of a dry standpipe located for each floor is mm. diameter.
51 mm (2”)
76 mm (3”)
38 mm (1 1/2”)
64 mm (2 1/2”)
Water as delivered by NAWASA is no longer safe for drinking because of several contaminants from the water source present in the environment. It is now therefore imperative that water to be safe for drinking has to undergo water purification in several stages. Because of several contaminants, water undergoes several stages. What is a stage in water purification, which removes mineral deposits, salts, heavy metal, totally dissolves solids while some useful minerals are retained?
carbon filtration
Aeration
ultraviolet radiation
reverse osmosis
What is a device installed on top of a pressure tank used to protect against hydrostatic collapse due to suction or negative pressure resulting from backsiphonage in a downfeed water distribution system?
pressure reducing valve
vacuum breaker valve
air volume control valve
pressure relief valve
What is a type of vent applied on installations with multi-branch interval where the vertical vent pipe takes off in front of the first fixture and connects to a main vent stack?
Relief vent
Yoke vent
Loop vent
Circuit vent
What is the size of supply inlet for flush tank type water closet?
3/4”
1/2”
3/8”
1”
Where are dampers installed to regulate the amount of cool air for an even distribution to outlets?
at the trunk ducts
at a practical location at angles and elbows
at the branch supply duct as far as practical from the outlet
at the air boot fitting
A kind of G.I. fitting used as a reducer from a bigger diameter to a lesser diameter.
Bushing
Reducer
Fitting
Union