WorksheetsARCH 501: LONG QUIZ 1
Total questions: 30
Worksheet time: 17mins
Minimum clear width of doors in BP344?
900 mm
800 mm
850 mm
950 mm
According to BP344, the door closer device pressure on an interior door shall not exceed how many kilogram (kg)?
3.0 kg
5.0 kg
6.0 kg
4.0 kg
TRUE OR FALSE.
Absolutely no abutments are allowed at any property line for any R-1 lot type/location.
FALS
TRUE
The Minimum Front Setback for R-1 (Residential) Structures.
4.50 meters
5.50 meters
5.00 meters
4.00 meters
TRUE OR FALSE.
Firewalls are absolutely not prohibited for R-1 lots.
TRUE
FALSE
What is R-1?
Low density residential zone, characterized mainly by townhouses, row houses, and duplexes intended for compact living with limited shared open spaces.
Low density residential zone, characterized mainly by low-rise apartment buildings and condominium clusters designed for multi-family occupancy.
Low density residential zone, characterized mainly by single family, single detached dwellings with the usual community ancillary uses on a neighborhood scale, such as executive subdivisions and relatively exclusive residential communities which are not subdivisions.
Low density residential zone, characterized mainly by mixed-use housing where residential dwellings are integrated with small commercial and institutional facilities.
BP 344 (Batas Pambansa Bilang 344) is also known as?
Accessibility Law
National Building Code of the Philippines
Fire Code of the Philippines
National Plumbing Code of the Philippines
BUILDING HEIGHT LIMIT (BHL) is the maximum height to be allowed for buildings/structures
based on their proposed use or occupancy.
For R-1, what is the Building Height Limit?
1 storey (bungalow)
2 storey/s
3 storeys/
1 storey with loft
In BP344, entrance/s and exit/s of the building shall be provided with what to protect all the PWDs as well as on-PWDs from rain.
Arcade
Polycarbonate roofs
Trellises
Overhanging Roof (canopy)
Minimum hallway width in BP344?
1500 mm
1300 mm
1100mm
1200 mm
(BP344) For doors with peepholes, provide a secondary peephole at a height of ___ from the finish floor for wheelchair users.
1.10 m
1.20 m
900 mm
1500 mm
(BP344) Doors along major circulation routes should be provided with ______ made of durable materials at a height of 300 mm to 400 mm.
Strong Plates
Louver Plates
Door Stopper
Kick Plates
Minimum width of Side Setback for R-1?
4.50 m
5.50 m
3.00 m
2.00 m
Minimum sizes of rooms for human habitations?
3.00 sqm
9.00 sqm
6.00 sqm
10 sqm
Mezzanine floors shall have a clear ceiling height not less than ___ above and below it.
2.70 meters
2.50 meters
2.00 meters
1.80 meters
Minimum sizes of courts and yards and their least dimensions shall be governed by the use, type of
construction, and height of the building as provided hereunder, provided that the minimum horizontal
dimension of said courts and yards shall be not less than __ meters.
1.20 m
1.50 m
2.00 m
2.20 m
Eaves, canopies, awnings (or media agua) over required windows shall not be less than ____
millimeters from the side and rear property lines.
650
750
850
950
TRUE OR FALSE.
There shall absolutely be no openings on/at/within/through all types of abutments (such as
firewalls) erected along property lines except for permitted vent wells.
TRUE
FALSE
Minimum Lot Sizes in sqm for R1 if it is an Interior Lot?
548 sqm
365 sqm
301 sqm
300 sqm
Minimum Lot Sizes in sqm for R1 if it is an Corner Lot or Through Lot?
548 sqm
365 sqm
301 sqm
300 sqm
The minimum clear level space of ____________ shall be provided before and extending beyond a door
1800 mm x 1800 mm
1600 mm x 1600 mm
1700 mm x 1700 mm
1500 mm x 1500 mm
Clear openings shall be measured from the face of a fully open door at _______ and the door jamb
90 degrees
80 degrees
70 degrees
60 degrees
According to BP 344, which of the following statements is correct
In cases where frameless transparent glass doors and any other vertical transparent glass panels are provided, such glass panels should be provided with horizontal or graphical patterns with contrasting gray value color against adjacent and background colors, between 800 mm and 1.50 m above the floor to prevent PWDs from bumping against it.
In cases where frameless transparent glass doors and any other vertical transparent glass panels are provided, such glass panels should be provided with horizontal or graphical patterns with contrasting gray value color against adjacent and background colors, between 900 mm and 1.50 m above the floor to prevent PWDs from bumping against it.
In cases where frameless transparent glass doors and any other vertical transparent glass panels are provided, such glass panels should be provided with horizontal or graphical patterns with contrasting gray value color against adjacent and background colors, between 800 mm and 2.50 m above the floor to prevent PWDs from bumping against it.
In NBCP, Entrance or Exit, the minimum
number of steps shall be two (2) with risers not exceeding ________
400 mm
300 mm
100 mm
200 mm
Under Table VIII. G.6 of NBCP, The minimum percentage of open space of R-1 Inside Lots without Firewalls or Abutments.
20 %
30 %
40 %
50 %
Under Table VIII. G.6 of NBCP, The minimum percentage of open space of R-1 Interior Lots without Firewalls or Abutments.
20 %
30 %
40 %
50 %
Under Table VIII. G.6 of NBCP, The minimum percentage of open space of R-1 Corner or Through Lots without Firewalls or Abutments.
20 %
30 %
40 %
50 %
In case entrances are not on the same level of the site arrival grade, what should be provided as access to the entrance level?
Accessible Elevators
Accessible Stairs
Accessible Doors
Accessible Ramps
Habitable rooms provided with artificial ventilation shall have ceiling heights not less than _____
measured from the floor to the ceiling;
2.10 m
2.40 m
2.70 m
1.80 m
According to the Building Code, rooms intended for any use that are not provided with artificial ventilation systems must have windows with a total free area of openings equal to at least what percentage of the floor area of the room?
5%
20%
10%
15%