Font size
WorksheetsChemical Reagents and Laboratory Supplies
Total questions: 76
Worksheet time: 39mins
It is suitable for use in most analytic procedure.
Ultrapure
Chemically pure
Technical or Commercial grade
Analytic Reagent
It is not recommended for use in the clinical laboratories for reagent preparation.
Analytic reagent
Chemically Pure
Technical or Commercial grade
National Formulary
What is a highly purified chemical that can be measured directly to produce a substance of exact known concentration and purity?
Primary standard
Secondary standard
Tertiary standard
Quaternary standard
What is a substance of lower purity with concentration determined by comparison with a primary standard?
Primary standard
Secondary standard
Tertiary standard
Quaternary standard
What type of reagent grade water is used for methods requiring minimum interference?
Type I
Type II
Type III
What type of reagent grade water is acceptable for most analytic requirements?
Type I
Type II
Type III
What type of reagent grade water is used for washing and rinsing glassware?
Type I
Type II
Type III
This is routinely expressed as "parts per 100".
Percent
Molarity
Molality
Normality
This is expressed as number of moles per 1 liter of solution.
Percent
Molarity
Molality
Normality
This is expressed as amount of solute per 1 kilogram of solvent.
Percent
Molarity
Molality
Normality
This is often used in chemical titration.
Percent
Molarity
Molality
Normality
What is the unit for normality?
mol/L
mol/kg
equivalents/L
%
It has a relatively low solute.
Dilute
Concentrated
Saturated
Supersaturated
It has an even greater concentration of undissolved solute particles than a saturated solution of the same substance.
Dilute
Concentrated
Saturated
Supersaturated
It has a large quantity of solute in solution.
Dilute
Concentrated
Saturated
Supersaturated
It is a solution with an excess of undissolved solute particles.
Dilute
Concentrated
Saturated
Supersaturated
It refers to the pressure at which the liquid solvent is in equilibrium with water vapor.
Vapor pressure
Freezing point
Boiling point
Osmotic pressure
It is the temperature at which the vapor pressure of the solvent reaches the atmosphere.
Vapor pressure
Freezing point
Boiling point
Osmotic pressure
It is the temperature at which the vapor pressure of the solid and liquid phases are the same.
Vapor pressure
Freezing point
Boiling point
Osmotic pressure
It is the pressure that allows solvent to flow through a semi-permeable membrane.
Vapor pressure
Freezing point
Boiling point
Osmotic pressure
It has the ability to accept electrons.
Reducing agent
Oxidizing agent
It has the ability to lose electrons.
Reducing agent
Oxidizing agent
It is a measure of how well electricity passes through a solution.
Conductivity
Resistivity
It is a measure of a substance's resistance to the passage of electric current.
Conductivity
Resistivity
These are weak acids and bases which minimizes change in pH.
Buffers
Salts
Reducing agent
Oxidizing agent
What substance is present in a liquid-in-glass thermometer in place of mercury?
Distilled water
Gallium
Cesium
Francium
It is a type of thermometer that can measure temperature in millisecond and is expensive.
Liquid-in-glass
Thermistor probe
Digital thermometers
Tachometer
Which option does not belong to the group?
Liquid-in-glass
Tachometer
Thermistor probe
Digital thermometer
It is an all-purpose glass. It can tolerate heating and sterilization for lengthy periods of time to 510 degrees Celsius.
Vycor
Corex
Pyrex/Kimax
What is the type of material present in Corex?
Borosilicate with low alkaline content
Aluminosilicate
95% silica
It is used in ashing and ignition techniques. It can withstand very high temperature (900-1200 degrees Celsius), as well as drastic temperature change.
Pyrex/Kimax
Corex
Vycor
It is the type of material that is used to make cuvettes and thermometers and is optically pure.
Borosilicate with low alkaline content
Aluminosilicate
95% silica
It is the type of material that can be used with strong alkali and suffer minimal attack.
Borosilicate with low alkaline content
Aluminosilicate
95% silica
This substance is used to rinse micropipettes with blood clot.
Distilled water
Acetone
Sodium hypochlorite
Sodium hydroxide
It contains slightly more than the designated "to deliver" volume because it is impossible to drain a burette, pipette, or flask completely.
To deliver glassware
To contain glassware
A TD pipette which does not have a frosted ring/band close to the mouthpiece.
drainage delivery
blowout delivery
A TD pipette which contains a frosted ring/band and the last few drops are blown out after free drainage is complete.
drainage delivery
blowout delivery
"Deliver the amount"
To deliver glassware
To contain glassware
"Do not deliver the same volume"
To deliver glassware
To contain glassware
It has a continuous etched ring or two small, continuous rings located near the top of the pipette.
To blow-out
Self-draining
It does not have markings or etched ring and the user allows the contents of the pipette to drain by gravity.
To blow-out
Self-draining
It is calibrated to hold one exact volume of liquid.
Graduated cylinders
Erlenmeyer flasks
Volumetric flasks
Griffin beakers
It is used to measure volumes of liquid.
Graduated cylinders
Erlenmeyer flasks
Griffin beakers
Volumetric flasks
It is designed to hold different volumes rather than one exact amount.
Graduated cylinders
Erlenmeyer flasks
Griffin beakers
Volumetric flasks
It is a self-draining pipette with no graduations at the tip, the tip is not allowed to touch the vessel while the pipette is draining and full volume should be used to achieve proper accuracy.
Mohr pipette
Micropipette
Serologic pipette
Otswald-Folin pipette
It is a blown-out pipette that has a calibration mark to the tip.
Mohr pipette
Serologic pipette
Micropipette
Otswald-Folin pipette
It has a total holding volume of less than 1mL.
Otswald-Folin pipette
Micropipette
Serologic pipette
Volumetric pipette
It is a blow-out pipette used in viscous liquids.
Micropipette
Mohr pipette
Serologic pipette
Otswald-Folin pipette
It is a self-draining pipette that is designed to transfer aqueous solutions.
Mohr pipette
Serologic pipette
Otswald-Folin pipette
Volumetric pipette
It is designed to dispense one volume without further subdivisions.
Volumetric pipette
Transfer pipette
Otswald-Folin pipette
Mohr pipette
It is used to transfer solutions or biologic fluids without considerations of a specific volume.
Mohr pipette
Otswald-Folin pipette
Volumetric pipette
Pasteur pipette
It is the most frequently used pipette in the clinical chemistry laboratory.
Pasteur pipette
Automatic pipette
Otswald-Folin pipette
Serologic pipette
Which of the following is not a type of automatic pipette?
Air displacement pipette
Positive displacement pipette
Negative displacement pipette
Dispenser pipette
It relies on a piston for suction creation to draw the sample into a disposable tip that must be changed after each use.
Air displacement pipette
Positive displacement pipette
Negative displacement pipette
Dispenser pipette
It operates by moving the piston in the pipette tip or barrel and does not require a different tip for each use, but rinsing and blotting may be required.
Air displacement pipette
Positive displacement pipette
Negative displacement pipette
Dispenser pipette
It is used to obtain the liquid from a common reservoir and dispense it repeatedly.
Air displacement pipette
Positive displacement pipette
Negative displacement pipette
Dispenser pipette
It is used during titration process.
Pipettes
Burettes
Syringes
Dessicators
It is used for blood gas analysis.
Burettes
Pipettes
Syringes
Dessicators
It is primarily used to prevent moisture absorption.
Burettes
Pipettes
Syringes
Dessicators
It is used in calibrating centrifuges.
Thermometer
Barometer
Tachometer
Speedometer
It is a process in which centrifugal force is used to separate solid matter from a liquid suspension.
Centrifugation
Decantation
Filtration
Dialysis
It is the calibrating medium for TD pipettes.
Mercury
Distilled water
Acetone
10% sodium hypochlorite solution
It is the calibrating medium for TC pipettes.
Mercury
Distilled water
Acetone
10% sodium hypochlorite solution
It is used to verify pipette volume accuracy and precision.
Gravimetric methods
Fluorometric methods
Spectrometric methods
Colorimetric methods
It is used to compare the reproducibility of brands of the pipette.
0.1% phenol red solution in distilled water
0.5% phenol red solution in distilled water
0.2% phenol red solution in distilled water
0.9% phenol red solution in distilled water
What class of pipette does not require calibration?
Class D
Class C
Class B
Class A
It is a cleaning solution for glassware.
Acetone
Distilled water
Sodium hypochlorite
Acid dichromate
Plastic pipette tips are made primarily of
Polyethylene
Polystyrene
Polypropylene
1 lambda is equal to
1 milligram
1 microliter
1 milliliter
1 cubic mm
This refers to all samples loaded at the same time, and a single test is conducted on each sample.
Batch testing
Parallel testing
Random access testing
Sequential testing
It refers to more than one test that is analyzed concurrently on a given clinical specimen.
Batch testing
Parallel testing
Random access testing
Sequential testing
It refers to any test that can be performed on any sample in any sequence.
Batch testing
Parallel testing
Random access testing
Sequential testing
It refers to multiple tests analyzed one after another on a given specimen.
Batch testing
Parallel testing
Random access testing
Sequential testing
It is a system other than the manufacturer's reagent that can be utilized for measurement.
Batch reagent system
Sequential reagent system
Open reagent system
Closed reagent system
It is a system where the operator can only use the manufacturer's reagent.
Batch reagent system
Sequential reagent system
Open reagent system
Closed reagent system
It relies on a piston for suction creation to draw the sample into a disposable tip that must be changed after each use.
Air displacement pipette
Positive displacement pipette
Negative displacement pipette
Dispenser pipette
