1.

Current-carrying conductors used in the AC system of an RV are required to be of the

a)

low voltage type

b)

solid copper type

c)

stranded copper type

d)

flexible copper type

2.

In determining wire size by gauge, the larger the gauge number ,the

a)

longer the wire length required

b)

more over current provided

c)

larger the wire

d)

the smaller the wire

3.

When measured with an ohmmeter , an unfailed overcurrent protection device will have

a)

zero resistance

b)

very high resistance

c)

12 VDC

d)

120 VAC

4.

In the following schematic diagram (edit the graphics S1=A R1=B R2=C C1=D C2=E T1=F

a)

D and E are batteries

b)

A is closed

c)

F is a relay

d)

B and C are resistors

5.

The distribution panel image would require

a)

50 amp shoreline

b)

65 amp shoreline

c)

30 amp shoreline

d)

15 shoreline

6.

The following symbol is

a)

closed contact

b)

open contact

c)

inductor(coil)

d)

fixed resistor

7.

The following symbol is a

a)

single pole , single throw

b)

single pole double throw

c)

double pole double throw

d)

double pole single throw

8.

If resistance is added to a series circuit , the current flow

a)

increases

b)

remains the same

c)

decreases

d)

none of the above

9.

An ohm is a measurement of

a)

power

b)

current

c)

resistance

d)

voltage

10.

Determine the wattage of an AC circuit that draws 15 amps at 120 VAC

a)

8 watts

b)

18 watts

c)

180 watts

d)

1800 watts

11.

Which bulb will use the least amperage

a)

115V,60 w

b)

115V,100w

c)

12V ,60W

d)

12V , 100w

12.

Arefrigerator is not functioning properly in the electrical mode (no cooling) The resistance of the heating element reveals that it has 20.75 ohms of resistance. The data plate indicates that the refrigerator heating element should draw 325 W on 120VAC . The technician should

a)

check for 120 on the heating element

b)

replace with a higher wattage element

c)

check the size of circuit breaker

d)

replace the heating element

13.

when raising the voltage of a 120 VAC resistive load, its amperage draw will

a)

increase

b)

remain the same

c)

decrease

d)

increase 1 amp for every 10 volts

14.

the ground and neutral wires from the 120 VAC shoreline power should be attached

a)

to a separate buss bar

b)

in the same buss bar

c)

to the converter case

d)

to the circuit breaker case

15.

What color wire is present in the 50 amp shore cord that is not present in a 30 amp shore cord

a)

blue

b)

red

c)

yellow

d)

black

16.

If a 50 amp distribution center ,when plugged into a 50amp shore power , what is the voltage between Leg 1 and neutral as measured in the coach distribution panel?

a)

0 VAC

b)

12VAC

c)

120VAC

d)

240VAC

17.

the neutral in the distribution panel board of an RV must

a)

always be connected to the ground buss bar

b)

always remain isolated from ground

c)

always be of stranded wire

d)

never be connected to a breaker

18.

The neutral wire connected to the 120 VAC shore line power should be ungrounded

a)

in all 120 VAC RV wiring

b)

only in RVs employing more than 3 more branch circuits

c)

only when 30 amp service is used

d)

only in Class A motor homes

19.

How does an RV get an earth ground

a)

from the tires on the ground

b)

from shoreline attached to pedestal

c)

from buss bar in distribution panel

d)

from grounding RV chassis

20.

On a motor home with a 50 amp power supply cord , the total AC amp capacity available to that coach would be

a)

50 amp

b)

100 amp

c)

dependent on the number of circuit

d)

dependent on the length of the cord

21.

A 50 amp shore power outlet has how many watts of power ?

a)

3000

b)

3600

c)

5500

d)

12000

22.

In the following image the white wire should be connected at the distribution panel to

a)

an isolated neutral buss bar

b)

to ground buss bar

c)

to circuit breaker

d)

to the metal of the panel

23.

In the following image the black wires should be connected at the distribution panel

a)

an isolated neutral buss bar

b)

to ground buss bar

c)

to circuit breaker

d)

to the metal of the panel

24.

What is the voltage reading between A and B

a)

12 VAC

b)

12 VDC

c)

120 VAC

d)

120VDC

25.

When replacing a distribution panel board , what electrical cabling is typically used on the AC side

a)

service jr (SJ) wire

b)

romex or nm electrical cable

c)

stranded

d)

extension cable

26.

While troubleshooting an intermittent voltage drop on the AC system , a possible cause is

a)

a loose or faulty connection in the distibution panel

b)

improper wire size

c)

intermittent converter output

d)

incorrect generator frequency

27.

If a customer complains of low voltage at the AC panel , the technician should FIRST

a)

recalibrate his/her meter

b)

check voltage at the pedestal

c)

check the polarity indicator

d)

replace the overcurrent protection device

28.

A technician needs to install a 13500 BTU/hr air conditioner. what is the minimum gauge of non metallic sheathed cable required ?

a)

14/3

b)

12/3

c)

14/2

d)

12/2

29.

All of the following can be causes of low voltage conditions EXCEPT

a)

undersized conductor

b)

bad connections

c)

Undersized overcurrent protection

d)

discharged batteries

30.

A voltmeter must always be connected

a)

in series with the source

b)

on the positive side

c)

in parallel with the circuit or load

d)

in relationship to the component

31.

To manually discharge an air conditioner's run capacitor , a technitian should set the AC voltmeter to

a)

highest AC scale

b)

120 VAC

c)

12VDC

d)

240VDC

32.

If a 15 amp breaker continues to blow after you have verified a 9 amp load you should replace

a)

heat spring

b)

contacts

c)

heat bar

d)

breaker

33.

If a 120 VAC circuit breaker will not reset the technician should

a)

disassemble and clean the contacts

b)

disassemble and replace the contacts

c)

replace the breaker with one of the same amperage

d)

replace the breaker with one of higher amperage

34.

When installing a new circuit breaker , the hot wire(black) should be

a)

hand tightende

b)

tightened half past contact

c)

torqued to specification

d)

as tight as tool can be without stripping

35.

An exterior 120 VAC receptacale is on a CGIF protected circuit with multiple outlets. There is no voltage present at only one of the receptacles in the bathroom. what is the possible cuase

a)

GFCI test button is tripped in the bathroom

b)

GFCI is incorrectly wired in the bathroom

c)

GFCI breaker is tripped

d)

the main circuit breaker is off

36.

A GFCI on a 120 VAC circuit operates by sensing an imbalance of

a)

voltage between hot and ground

b)

voltage between hot and neutral

c)

current between hot and ground

d)

current between hot and neutral

37.

The connector on a GFCI receptacle that is labeled LOAD is

a)

the same as line input

b)

the power coming into the receptacle

c)

the outlet that is downstream of the GFCI

d)

should never have wiring connected

38.

GFCI protection can be provided though specific GFCI receptacles or GFCI

a)

circuit breakers

b)

diodes

c)

capacitors

d)

conductors

39.

Which of the following likely contributes to a hot skin condition?

a)

incorrect polarity of the battery system

b)

incorrect polarity of the shore cord

c)

shore cord voltage too high

d)

converter voltage feedback

40.

What is the most common hot skin problems in RVs

a)

blown fuses

b)

tripped breakers

c)

high resistance shorts

d)

dead shorts

41.

What is the correct meathod for performing a hot skin test on an RV

a)

unplug the RV from shore power and use a VOM to check for voltage between a bare metal surface on the RV and the neutral grounding bar

b)

with a generator running use a VOM to check for voltage between a bare metal surface on the RV and a known earth ground

c)

with batteries fully charged use aVOM to check for voltage between a bare metal surface on the RV and the neutral grounding bar

d)

plug the RV into shore power and use a VOM to check for voltage between a bare metal surface on the RV and a known earth ground

42.

On a hot skin test the RV breakers must be

a)

off

b)

open

c)

on

d)

removed

43.

Technician A says that a generator's neutral and ground must be tied together when the generator is supplying AC power . Tech B says that they must always be kept isolated. which tech is correct

a)

tech A

b)

techB

c)

both

d)

neither

44.

A customer reports that the generator will not start from either the remote control panel .

All of the following are likely causes except

a)

low battery voltage

b)

bad starter solenoid

c)

faulty start switch on the remote panel

d)

loose or poor connections

45.

When the generator is running and supplying power but there is no power to the distribution panel , what is the possible cuase

a)

improper speed of generator

b)

weak converter

c)

faulty transfer switch

d)

inverter turned off

46.

A typical RV transfer switch is activated whenever

a)

the coach is plugged into shore power

b)

the inverter is plugged in

c)

the generator is started

d)

the batteries need changing

47.

An inverter is used to convert

a)

AC to AC power

b)

DC to AC power

c)

AC to DC power

d)

DC to DC power

48.

Before replacing an inverter the technician should always

a)

turn the branch breaker on

b)

disconnect the battery isolator

c)

disconnect battery and AC connection

d)

short across battery terminal + to ground to discharge filters

49.

For inverter installation it is important to do all of the following except

a)

adequately size inverter output for connected loads

b)

provide AC overcurrent circuit protection

c)

provide DC overcurrent protection

d)

use large cranking batteries

50.

It is recommended that inverters be installed

a)

in the generator compartment

b)

in a protective box

c)

in the forward hanging locker

d)

near the batteries

51.

When moving a 120 VAC outlet and the wire is short you should

a)

splice the wire with scotch locks

b)

replace the wire with a new one of the proper length

c)

use only crimping connectors and splice

d)

replace the outlet with a larger one

52.

According to NFPA where cable connections or clamps are used , the cables need to be secured and supported within

a)

6" of the outlet boxes junction boxes and panel boards

b)

12" of outlet boxes , junction boxes and panel boards

c)

not necessary if installed inside a cabinet or wall

d)

not necessary

53.

Relating to RV wiring , any area accessible to the RV owner for storage or in a traffic area is considered to be

a)

acceptable for uncovered RV wiring

b)

acceptable for RV wiring as long as it is covered and protected

c)

unacceptable if RV wiring is present

d)

subject to physical damage in outside compartments only

54.

Which of the following is NOT a protection for non metallic sheathed cable

a)

rigid metal conduit

b)

intermediate metal conduit

c)

rubber hose conduit

d)

liquid tight flexible conduit

55.

Exterior receptacals are required to

a)

only have a weather proof cover

b)

be protected by a GFCI device

c)

be on an isolated circuit

d)

to be the only recepticale

56.

Exterior receptacles must have

a)

a cover that opens up

b)

a cover that opens down

c)

a wet location cover

d)

a weather proof gasket

57.

What is the function of an energy managment system

a)

optimize generator efficiency

b)

optimize 12VDC distribution

c)

optimize 120VAC distribution

d)

optimize inverter efficiency

58.

If an RV with a 30 amp power supply ha smore than two 120 VAC thermostatically controlled appliances what must be done

a)

an extra circuit breaker must be installed

b)

an energy management system must be installed

c)

nothing no action needed

d)

only one of the controlled appliances can be used at a time

59.

Which of the following is not a type of energy management system (EMS)

a)

manual

b)

automatic

c)

programable

d)

on- demand

60.

The principle function of an EMS is to

a)

balance AC loads in distibution panels

b)

boost the available power

c)

shed load

d)

protect the appliences from over current

61.

Prior to adding new electrical device the technician should identify all of the following except

a)

voltage amperage wattage required

b)

circuit and devices attached to the circuit

c)

manufacturer of the device

d)

capacity of circuit to accommodate the new device

62.

When adding a new device and no receptacle is provided the equipment cannot exceed _______of branch cicuit

a)

50%

b)

25%

c)

75%

d)

100%

63.

When there are six or more circuits in a RV the minimum power supply assembly is a

a)

30 amp without an energy management system

b)

50 amp distibution panel

c)

two 120 volt circuits

d)

30 amp with energy management system