L3 YR2 revision 5 (Heating)

Total questions: 60

Worksheet time: 30mins

Name
Class
Date
1.

Part L1b of the Building Regulations covers

a)

The Water Supply (Water Fittings) Regulations 1999

b)

Conservation of fuel and power in new dwellings

c)

Conservation of fuel and power in existing dwellings

d)

Conservation of fuel and power in new commercial dwellings

2.

Heat producing appliances come under which part of the Building Regulations?

a)

Part F

b)

Part C

c)

Part J

d)

Part L

3.

What is the maximum floor area of a dwelling before separate zones have to be introduced?

a)

120M squared

b)

100M squared

c)

130M squared

d)

150M squared

4.

Which British Standard covers Heating systems in buildings?

a)

BS EN 12828:2003

b)

BS EN 442:2003

c)

BS EN 806

d)

Part G Building Regulations

5.

Which of the following documents offers compliance advice and best practice for the installation of central heating systems?

a)

Domestic Building Services Guide

b)

CIPHE Heating Guide

c)

BS EN 7593

d)

Central Heating System Specifications (CHeSS) 2008

6.

What type of valve should be fitted to the cold feed to an open vented heating system?

a)

Gate valve

b)

Stop valve

c)

Lever operated valve

d)

No valve to be fitted

7.

If the flow temperature from a condensing boiler is 80 degrees. What temperature would you expect on the return when commissioning?

a)

50 degrees

b)

60 degrees

c)

70 degrees

d)

80 degrees

8.

The S plan system has the following:

a)

Room stat, cylinder stat, programmer 3 x two port valves

b)

Room stat, cylinder stat, programmer 1 x two port valve

c)

Room stat, cylinder stat, programmer 2 x two port valves

d)

Room stat, cylinder stat, programmer 4 x two port valves

9.

The function of a bypass is required for what?

a)

Overheat protection of the hot water circuit

b)

Overheat protection of the boiler

c)

Overheat protection of the bi metallic strip

d)

Overheat protection of the solonoid

10.

What is the function of a wiring centre?

a)

A technical help line

b)

To order electrical cable and accessories

c)

To enable all component wiring to be linked together

d)

To make a spur connection to a system

11.

Open vented systems contain a feed and expansion cistern which fulfills two functions which are:

a)

It allows for overheat protection and temperature control for the heating boiler

b)

It is to allow for a good flow and pressure to a thermostatic mixer valve

c)

It allows space for the system water to expand to when it is heated and a means by which water enters the system for filling and top-up

d)

It allows the water to overflow when fill valve fails and protects against system corrosion

12.

What is the recommended capacity of an F & E cistern?

a)

5 litres

b)

18 litres

c)

10 litres

d)

32 litres

13.

What is the purpose of an "Open vent" in regard to heating systems?

a)

Provide a safety outlet should system overheat and ensures system remains at atmospheric pressure limiting boiling point to 100 degrees

b)

Provide a safety outlet should system overheat and ensures system remains at atmospheric pressure limiting boiling point to 80 degrees

c)

Provide a safety outlet should system overheat and ensures system remains at atmospheric pressure limiting boiling point to 50 degrees

d)

Provide a safety outlet should system overflow and ensures system remains an intensity of pressure of 9.81 Kn/M2

14.

In a fully pumped system the height of the open vent should be a minimum of ....? from the water level in the cistern to the top of the open vent pipe.

a)

250mm

b)

350mm

c)

450mm

d)

550mm

15.

What is the name of the motor in a motorised valve?

a)

Stirling

b)

Syncron

c)

Microswitch

d)

Hybrid

16.

Three port valve provide separate hot water and heating circuits, they include a mid position which allows...

a)

Constant hot water demand

b)

Reverse circulation

c)

Reversed circuits

d)

Shared flow

17.

Under Part L Building Regulations heating systems must be

a)

Fully Primed

b)

Fully connected

c)

Fully Pumped

d)

Fully constricted

18.

To convert an open system to a sealed system the following additional controls are required

a)

Filling loop, pressure gauge, expansion vessel,

b)

filling loop, expansion cistern, pressure gauge

c)

expansion cistern, expansion vessel, pressure gauge

d)

filling loop shock arrester, expansion vessel

19.

Boiler interlock can be described as

a)

Boiler on/off switch

b)

Associated controls which prevents boiler firing when there is no demand

c)

Associated controls which prevents boiler firing when there is high demand

d)

Associated controls which prevents boiler firing when there is low demand

20.

Time clocks are devices which are

a)

Suitable for switching on multiple circuit

b)

Suitable for switching on two circuit

c)

Suitable for switching on one circuit

d)

Suitable for switching on all circuits

21.

The flow from a boiler is connected to which port on a three port valve

a)

B

b)

AB

c)

A

d)

CA

22.

The B port of a three port valve is connected to which circuit?

a)

Hot water

b)

Heating

c)

Boiler

d)

Secondary circuit

23.

A room thermostat should be fitted at a height of ....? from the floor

a)

1m

b)

1.5m

c)

2m

d)

2.5m

24.

What is the function of a weather compensator?

a)

As external temp rises the compensator increases the circulation temp of the flow from the boiler. The reverse occurs if weather gets warmer.

b)

As external temp rises the compensator reduces the circulation temp of the flow from the boiler. The reverse occurs if weather gets colder.

c)

It increase flow temp due to thermostats calling for heat.

d)

It reduces the emissions from the twin walled flue

25.

Which of the following is NOT an advanced heating control?

a)

Optimum start

b)

Delayed start

c)

Weather complicator

d)

Weather compensator

26.

Choosing the correct controls is vital. Which of the following is NOT an advantage.

a)

Reduced fuel bills

b)

Improved energy efficiency

c)

Improved boiler efficiency

d)

Lower CO2 emissions

27.

A good system of controls must ensure that the boiler does not operate unless there is a demand. This is known as

a)

Boiler interlink

b)

Boiler intergas

c)

Boiler intercity

d)

Boiler interlock

28.

The open vent and cold feed pipe should be positioned on the flow from the boiler on the suction side of the pump with a maximum of ____mm between them.

a)

100mm

b)

120mm

c)

140mm

d)

150mm

29.

What is meant by the neutral point?

a)

A point in the system which remains positive

b)

A point in the system which is neither positive nor negative

c)

A point in the system which remains negative

d)

A point in the system which is neither alkaline nor acidic

30.

What is meant by the index circuit in a heating system?

a)

The circuit with the least resistance

b)

The circuit with the most resistance

c)

The circuit with no resistance

d)

The circuit with the most resilience

31.

To which terminal does the grey wire connect from a mid position valve to a wiring centre?

a)

3

b)

5

c)

7

d)

9

32.

What is the use of a proving unit?

a)

To check the correct operation of hydraulic test equipment

b)

To check the correct operation of hydrostatic test equipment

c)

To check the correct operation of electrical test equipment

d)

To check the correct operation of dynamic test equipment

33.

A low loss header allows the creation of two separate circuits. These are:

a)

Primary flow and primary return

b)

Primary circuit and secondary circuit

c)

Primary gravity flow and secondary return

d)

To reduce system pressure and recharge

34.

Why should an expansion vessel be fitted onto the return pipe?

a)

Water is generally cooler and prevents legionella

b)

Water is generally flowing faster and places less stress on the vessel

c)

Water is generally warmer than flow and places more stress on the vessel

d)

Water is generally cooler than flow and places less stress on the vessel

35.

What is the function of a Schrader valve?

a)

Allows air in or out with an air tight seal

b)

Allows water in or out with an air tight seal

c)

Allows the motorised valve to open when heat is called for

d)

Allows the motorised valve to close when heat is called for

36.

What is the name of the device which can be used to permanently connect heating systems to mains cold water?

a)

Type EB backflow prevention device

b)

Type BA backflow prevention device

c)

Type CA backflow prevention device

d)

Type CB backflow prevention device

37.

What is the correct fluid category for central heating water?

a)

Fluid category 1

b)

Fluid category 2

c)

Fluid category 3

d)

Fluid category 4

e)

Fluid category 5

38.

A system by-pass is fitted to avoid?

a)

overheat protection of the pump

b)

overheat protection of the plate heat exchanger

c)

overheat protection of the boiler

d)

overheat protection of the boiler multifunctional valve

39.

Which of the following is not a solid fuel?

a)

Coal

b)

Coke

c)

Biomass

d)

Natural gas

40.

The appliance which extracts heat from one medium at a low temperature and transfers it to another at a high temperature is a

a)

Heat pump

b)

Water pump

c)

Slave cylinder

d)

Heat primer

41.

A multi-functional gas valve incorporates the following components

a)

thermoelectric safety shut off, reactor, solenoid valve, inlet test point.

b)

filter, thermoelectric safety shut off, regulator, solenoid valve, inlet test point, burner test point pilot adjuster.

c)

filter, thermometer, safety shut off, regulator, solenoid valve, inlet test point, flue test point, pilot adjuster.

d)

filter, regulator, solenoid valve, outlet test point, burner test point pilot adjuster.

42.

Which radiator connections are used in most domestic applications?

a)

BBOE

b)

BBA

c)

TBOE

d)

TBBO

43.

What is the definition of "viscosity" when referring to heating oil?

a)

The amount of heat given of per millilitre

b)

The running time of the oil using Boyles law

c)

How long a litre of oil will burn for

d)

Means thickness of oil and time it takes for oil to flow over a set distance.

44.

What are the three parts of an open flue?

a)

Primary flow, birds nest, secondary flow

b)

Secondary flue, terminal, primary flue

c)

Liner, closure plate, cowl

d)

Copex, backgutter, terminal

45.

Which of the following is NOT a type of heat emitter?

a)

Panel radiator

b)

Column radiator

c)

LST radiator

d)

LAP radiator

46.

Where would you recommend to fit a kick-space heater?

a)

Bedroom

b)

Utility room

c)

Kitchen

d)

Bathroom

47.

Which of the following is NOT a common mechanical control used on domestic heating systems?

a)

Wheel-head radiator valve

b)

Thermostatic radiator valve

c)

Auto air vent

d)

Anti gravity valve

e)

HepvO valve

48.

What is velocity?

a)

The measurement of the height (head) at which an object changes its position

b)

The measurement of the rate at which an object changes its position

c)

The SI unit to measure flow

d)

The SI unit to measure pressure

49.

What is the function of an anti-gravity valve?

a)

Prevents unwanted deadlegs

b)

Prevents unwanted gravity circulation to upstairs radiators

c)

Prevents unwanted gravity circulation to downstairs radiators

d)

Prevents unwanted flashbacks

50.

What are the correct design temperatures for underfloor heating under concrete floors and timber floor construction?

a)

40-45 degrees for concrete and 50-60 degrees for timber floors

b)

20-35 degrees for concrete and 40-50 degrees for timber floors

c)

30-35 degrees for concrete and 40-45 degrees for timber floors

d)

50-60 degrees for concrete and 60-70 degrees for timber floors

51.

When designing an underfloor heating system consideration needs to be given to the thermal resistivity of floor coverings. This is expressed as _______ rating.

a)
TOG
b)

LOG

c)

COG

d)

BOG

52.

Which would be the ideal method of laying underfloor heating pipes under hardwood floors or vinyl tiles?

a)

Snail pattern

b)

Series pattern

c)

Parallel Pattern

d)

Plumbers Pattern

53.

Hot flushing of a heating system is to remove what?

a)

installation debris

b)

jointing compound, flux residue and oils

c)

silicone compound, sawdust and oils

d)

medicine compound, plumbers mait and debris

54.

A heating system is balanced to ensure what?

a)

Flow and return temperatures are the same

b)

Even pressure distribution to all heat emitters

c)

Flow and return temperatures have a minimum differential of 50 degrees

d)

Even, heat distribution of heat to all heat emitters

55.

Fault: system discharging water from the feed and expansion cistern overflow when heating up. Find the solution.

a)

Increase the water level and reset the FOV to shut off at a higher level.

b)

Bend arm of FOV until water stops discharging

c)

Lower the water level and reset the FOV to shut off at a lower level.

d)

Reduce flow to FOV by closing service valve slightly

56.

Which of the following is NOT a sealed heating system component?

a)

Expansion vessel

b)

Expansion relief valve

c)

Type CA disconnector

d)

Pressure gauge

e)

Type AA non mechanical backflow prevention device

57.

Which is the correct configuration for an open vented system pipework?

a)

Thumb air vent, filling loop, air separator and expansion vessel

b)

Vent, feed, pump, by-pass and motorized valve

c)

Automatic air vent, feed and expansion cistern, motorized valve

d)

Feed, pump, vent, motorized valve and by-pass

58.

Every radiator MUST be fitted with a thermostatic radiator valve.

a)

True

b)

False

59.

Where would a low loss header typically be used?

a)

On emitters that contain multiple zones and different system layouts

b)

To compensate for water loss within the system

c)

On systems that contain zones and different sized heat emitters

d)

On systems that contain multiple zones and different heat emitters

60.

What does the acronym ChESS stand for?

a)

Central Heating System Specification

b)

Careful handling every system size

c)

Coal heating equals system sort

d)

Charles heat every solid substance