CT Scan Quiz

Total questions: 50

Worksheet time: 25mins

Name
Class
Date
1.

CT stands for:

a)

Contrast Tomography

b)

Computed Tomography

c)

Conventional Tomography

d)

Cranial Tomography

2.

The inventor of CT scan was:

a)

Wilhelm Roentgen

b)

Godfrey Hounsfield

c)

Marie Curie

d)

Wilhelm Weber

3.

The year in which the first clinical CT scanner was introduced:

a)

1965

b)

1972

c)

1980

d)

1950

4.

The unit used to measure CT numbers is:

a)

Gray

b)

Roentgen

c)

Hounsfield Unit

d)

Sievert

5.

The X-rays used in CT scanning are produced by:

a)

Gamma rays

b)

Radioactive isotopes

c)

X-ray tube

d)

Laser beams

6.

The primary advantage of CT over conventional radiography is:

a)

Higher dose

b)

Cross-sectional imaging

c)

Lower resolution

d)

Simpler operation

7.

The part of CT scanner that detects transmitted X-rays is:

a)

Gantry

b)

Detector array

c)

Collimator

d)

Couch

8.

The CT number for water is:

a)

0

b)

100

c)

-1000

d)

+1000

9.

The CT number for air is approximately:

a)

+1000

b)

0

c)

-1000

d)

+500

10.

The CT number for bone is approximately:

a)

-1000

b)

+1000

c)

0

d)

+500

11.

Slice thickness in CT affects:

a)

Spatial resolution

b)

Image contrast

c)

Both A and B

d)

None

12.

The CT image is composed of:

a)

Pixels only

b)

Voxels

c)

Lines

d)

Frames

13.

The mathematical process used in image reconstruction in CT is:

a)

Differentiation

b)

Integration

c)

Fourier Transform

d)

Filtration

14.

The CT gantry houses:

a)

Patient couch

b)

X-ray tube and detectors

c)

Computer

d)

Monitor

15.

In helical CT, the X-ray tube:

a)

Rotates in steps

b)

Rotates continuously

c)

Is fixed

d)

Moves up and down

16.

The pitch in helical CT refers to:

a)

Slice thickness

b)

Table movement per rotation

c)

Tube voltage

d)

Filter width

17.

The typical kVp range used in CT scanning is:

a)

50–70 kVp

b)

80–120 kVp

c)

140–160 kVp

d)

30–50 kVp

18.

The function of the collimator in CT is to:

a)

Filter noise

b)

Shape the X-ray beam

c)

Increase detector sensitivity

d)

Reduce scatter

19.

The matrix size of a standard CT image is:

a)

64×64

b)

128×128

c)

512×512

d)

1000×1000

20.

The slice thickness in CT is measured in:

a)

mm

b)

cm

c)

inches

d)

meters

21.

The X-ray tube in CT rotates around the:

a)

Table

b)

Detector

c)

Patient

d)

Room

22.

The main limitation of CT is:

a)

Long time

b)

High radiation dose

c)

Poor resolution

d)

No 3D capability

23.

The first generation CT scanner used:

a)

Multiple detectors

b)

Single detector

c)

Fan beam

d)

Spiral beam

24.

The reconstruction algorithm most commonly used is:

a)

Back projection

b)

Filtered back projection

c)

Simple addition

d)

Linear regression

25.

The contrast media used in CT are usually:

a)

Barium-based

b)

Iodine-based

c)

Gadolinium-based

d)

Saline

26.

The gantry tilt in CT is measured in:

a)

Degrees

b)

Radians

c)

cm

d)

mm

27.

The CT dose index (CTDI) measures:

a)

Image resolution

b)

Radiation dose

c)

Scan time

d)

Slice thickness

28.

The main purpose of filters in X-ray tubes is to:

a)

Reduce low-energy photons

b)

Increase intensity

c)

Focus beam

d)

Reduce scatter

29.

The discovery of X-rays was made by:

a)

Marie Curie

b)

Wilhelm Roentgen

c)

Ernest Rutherford

d)

William Coolidge

30.

X-rays are part of:

a)

Infrared radiation

b)

Visible light

c)

Electromagnetic spectrum

d)

Sound waves

31.

X-rays are produced when:

a)

Electrons hit the target anode

b)

Protons collide

c)

Neutrons decay

d)

Light is refracted

32.

The filament in an X-ray tube is made of:

a)

Copper

b)

Tungsten

c)

Silver

d)

Lead

33.

The target in the X-ray tube is made of:

a)

Iron

b)

Tungsten

c)

Aluminum

d)

Copper

34.

The anode angle in X-ray tubes affects:

a)

Beam quality

b)

Field size

c)

Both A and B

d)

None

35.

The protective housing of an X-ray tube prevents:

a)

Beam scatter

b)

Leakage radiation

c)

Electrical loss

d)

Cooling

36.

The function of the collimator in X-ray is to:

a)

Increase resolution

b)

Restrict beam size

c)

Increase exposure

d)

Produce contrast

37.

The unit of radiation exposure is:

a)

Gray

b)

Sievert

c)

Roentgen

d)

Becquerel

38.

The unit of absorbed dose is:

a)

Sievert

b)

Gray

c)

Roentgen

d)

Curie

39.

The unit of dose equivalent is:

a)

Sievert

b)

Gray

c)

Roentgen

d)

Becquerel

40.

The main advantage of digital radiography is:

a)

Longer exposure

b)

Immediate image viewing

c)

Poor image quality

d)

No contrast

41.

The kVp in X-ray controls:

a)

Quantity of X-rays

b)

Quality (penetration)

c)

Exposure time

d)

Filtration

42.

The mA in X-ray controls:

a)

Beam penetration

b)

Quantity of X-rays

c)

Patient dose

d)

Image contrast

43.

Scatter radiation can be reduced by using:

a)

Filter

b)

Grid

c)

Higher kVp

d)

Large field

44.

The focal spot size affects:

a)

Image sharpness

b)

Exposure

c)

Patient dose

d)

Beam filtration

45.

A higher kVp results in:

a)

More contrast

b)

Less contrast

c)

No effect

d)

Lower penetration

46.

The anode heel effect is due to:

a)

Filtration

b)

Geometry of the anode

c)

Scatter

d)

Reflection

47.

The photoelectric effect is dominant in:

a)

Low kVp range

b)

High kVp range

c)

Ultrasound

d)

MRI

48.

In X-ray imaging, the main form of noise is caused by:

a)

Quantum mottle

b)

Electric current

c)

Tube heating

d)

Beam hardening

49.

Beam hardening artifact is common in:

a)

X-ray

b)

CT

c)

Ultrasound

d)

MRI

50.

The primary control of patient dose in CT is:

a)

kVp

b)

mA and scan time

c)

Collimator

d)

Gantry tilt