WorksheetsAirbus A320 Electricals
Total questions: 74
Worksheet time: 37mins
The engine generators and APU generator are rated at _____ KVA.
50
70
90
110
The number 1 AC bus channel normally supplies power to _____ and to the _____ bus which supplies power to the _____ bus.
TR2 / AC ESS SHED / DC ESS SHED
TR1 / AC ESS SHED / DC ESS
TR1 / AC ESS / AC ESS SHED
TR1 / AC ESS / DC ESS SHED
The normal priority for supplying electrical power to the AC busses is:
External power, engine generators then APU
External power, APU, then engine generators
APU, external power then engine generators
Engine generators, external power then APU
The BATTERY BUS is normally powered by:
DC BUS 2
DC BUS 1 and DC BUS 2
DC bus 1 through a DC tie control relay.
DC bus 2 through a DC tie control relay.
An AC ESS FEED switch located on the overhead panel shifts the power source for the AC ESS bus from:
AC bus1 to AC bus 2
AC bus 1 to AC Grnd/Flt bus
AC bus 2 to AC bus 1
Which of the following AC busses can be powered by the emergency generator?
AC bus 1
AC bus 2
AC ESS bus / AC ESS SHED bus
The RAT is connected directly (mechanically) to the Emergency Generator
True
False
The emergency generator supplies power as long as:
The landing gear is down.
The RAT is deployed.
The RAT is deployed and the landing gear is down
The landing gear is up.
The BAT FAULT light will illuminate when:
Battery voltage is low
Charging current increases at an abnormal rate
Charging current decreases at an abnormal rate.
The IDG Fault light indicates:
An IDG oil overheat
IDG low oil pressure.
IDG low oil pressure or IDG oil overheat
IDG has been disconnected
If normal electrical power is lost; essential cockpit lighting is maintained for the:
Captain’s instrument panel.
Standby compass
Right dome light (provided the dome selector is not off).
All of the above.
You enter a dark cockpit, what action is necessary before checking the battery voltages?
You have to check that the external power is on.
You have to ensure that at least one battery is on.
You have to ensure that both batteries are on.
You have to verify that both batteries are off.
Having started the APU, how can you get the APU generator to power the electrical system?
The APU generator must be switch on.
By pushing the EXT PWR pushbutton thus disconnecting the external power.
By pushing the BUS TIE pushbutton.
Are there any limitations associated with disconnecting an IDG?
Never disconnect an IDG in flight, or push the IDG disconnect push button for more than 30 seconds.
There is no limitation
Never disconnect an IDG in flight, or push the IDG disconnect push button for more than 5 seconds.
Never disconnect an IDG unless the engine is running, nor push the IDG disconnect push button for more than 3 seconds.
Which voltage requires recharging or replacing the batteries?
20 volts or less.
24 volts or less.
25 volts or less.
26 volts or less.
The APU is supplying the electrical system. What is the order of priority for the different generators?
Engines, external power, APU.
APU, engines, external power.
External power, engines, APU.
APU, external power, engines.
The significance of the green collared circuit breakers is:
Green colored circuit breakers are monitored by ECAM
Green colored circuit breakers are not to be reset
Green colored circuit breakers are AC powered
Green colored circuit breakers are pulled when flying on battery power only
Green collared circuit breakers are pulled when flying on battery power only.
Green collared circuit breakers are pulled when flying on battery power only.
Green collared circuit breakers are monitored by the ECAM.
Green collared circuit breakers are not to be reset.
Green collared circuit breakers are AC powered.
With the EMER EXIT LT selector in the ARM position, which situation will activate the emergency lights and exit signs?
AC SHED bus unpowered
AC bus #1 unpowered
DC ESS SHED bus unpowered
DC bus #2 unpowered
If batteries are the only source of power in flight, how long will battery power be available?
Between 22 and 30 minutes depending on equipment in use.
Until the APU is started.
Two hours and 30 minutes dependent on equipment in use.
45 minutes dependent on equipment in use.
What is the minimum voltage when conducting a BATTERY CHECK?
28 volts.
Less than 60 amps in 10 seconds.
Greater than 24 volts.
Greater than 25 volts.
A battery fault light will illuminate when:
The batteries have auto disconnected due to low voltage
Battery voltage drops below a predetermined level
Battery charging current increases at an abnormal rate.
Which flight control computer will be inoperative with gear extension while in the Emergency Electrical Configuration?
FAC 1 and ELAC 1.
SEC 1
SEC 1 and ELAC 1
FAC 1
If the battery voltages are below the minimum, how do you charge them?
You have to call a mechanic because the batteries can only be charged by maintenance.
I have to check that the BAT pushbuttons are on and switch the external power on.
I have to switch the external power to ON and switch the batteries off.
I have to start the APU as the batteries can only be charged by the APU generator.
What is the function of APU GEN push button located on the overhead electrical panel?
Push this button to automatically start the APU.
When selected to OFF the APU generator field is de-energized.
Both are correct.
It is possible to parallel generators.
Yes, it is possible to parallel generators.
No, generators cannot be paralleled.
Generators can only be used in series, not in parallel.
Parallel operation of generators is unsafe and not recommended.
While operating on Emergency Electrical Power with the landing gear lowered which of the following control laws is in effect?
Backup.
Direct.
Alternate.
Backup or alternate
What cockpit lighting is available during an emergency electrical situation?
Emergency path lighting only.
Right side Dome light, main panel flood lights (left two columns only), and the standby compass light.
Located on normal circuit breaker panels.
Right side dome light, main panel flood lights, and the standby compass light.
What is the function of the GEN 1 LINE push button?
When selected OFF the avionics compartment isolation valves close.
When selected OFF the #1 generator powers all AC busses.
When selected OFF generator #1 is removed from all busses but continues to power one fuel pump in each wing.
During a routine flight, which of the following would result after the loss of Gen #2 and the subsequent start of the APU?
The APU would now power both sides of the electrical system.
All systems return to normal and the RAT must be restowed.
Eng gen #1 continues to power AC bus #1 and downstream systems. The APU powers AC bus #2 and downstream systems.
When does the RAT automatically deploy?
With the loss of two hydraulic systems.
Electrical power to both AC BUS #1 & #2 is lost and the aircraft speed is above 100 knots.
Both are correct.
During the five seconds it takes for the RAT to extend:
The BATTERIES power both BATT HOT busses, ESS DC SHED, and ESS AC SHED through the STATIC INVERTER.
The BATTERIES power both BATT HOT busses, ESS DC, and ESS AC through the STATIC INVERTER.
The STATIC INVERTER powers both BATT HOT busses, ESS DC, and ESS AC through the ESS AC SHED busses.
The BATTERIES power both BATT HOT busses.
The purpose of the AUTO BUS TIE is to allow either engine-driven IDG to automatically power both main AC buses in the event of a generator loss until either ground power or the APU generator is activated.
True
False
When will the RAT & EMER GEN red FAULT light illuminate?
When the EMER GEN is not supplying electrical power, AC busses #1 & #2 are unpowered and the nose gear is up.
When the RAT is deployed using hydraulic RAT MAN ON push button.
Both are correct.
What is the significance of the circuit breakers on the overhead panel?
They are not monitored by ECAM.
Cannot be reset.
They may be operational in the Emergency Electrical Configuration.
They are mainly AC powered.
If both engine generators are powering the system, and one subsequently fails, are any busses unpowered?
Only the AC ESS shed bus.
No, but some loads are shed in both main galleys.
Yes, those associated with the failed generator.
How many times can you reset a circuit breaker?
Once.
Once, if authorized by the procedures.
Twice.
Twice, if authorized by the procedures.
On the cockpit overhead panel, there is a three position EMERGENCY EXIT Light switch. What lights are associated with this switch?
Exit signs, emergency lights, and escape path lighting.
Exit signs, emergency lights, main panel flood lights, and escape path lighting.
Exit signs, emergency lights, dome lights, main panel flood lights, and the standby compass light.
Which flight control computers are operational in the Emergency Electrical Power configuration (gear down and batteries powering the system)?
All are operational.
ELAC 1, SEC 1, and FAC 1.
ELAC 1 and 2, SEC 1 and 2, FAC 1.
ELAC 1 and SEC 1.
Which radios are inoperative with gear extension while in the emergency electrical configuration?
DME 1 and transponder 1.
DME 1, DDRMI, and transponder 1.
DME, and transponder 1.
ILS 2, DME, and ADF.
While operating on Emergency Electrical Power with the landing gear lowered which of the following statements is correct?
If the APU is not operating it should be started at this time
The APU will not start until the aircraft has come to a complete stop and all power has been removed for 15 seconds
On the ground at 100 knots, the DC BATTERY BUS automatically reconnects to the batteries allowing APU start
At 70 knots ESS AC is disconnected from the batteries
If during a normal flight the BUS TIE push button is depressed to “OFF”, what effect would this have on power to the busses?
None.
All power would be lost and the aircraft would be powered by the batteries until the RAT was up to speed.
The power transfer would switch to the opposite bus.
This is not possible as the bus tie contactors are locked out during flight.
While operating on Emergency Electrical Power (EMER GEN powering the system, FAC #1 reset) which of the following control laws are in effect?
Manual
Alternate.
Backup
Manual and backup
Can you reconnect an IDG in flight?
Yes, but only after contacting maintenance control.
Yes, push and hold the IDG pb until the GEN fault light is no longer illuminated.
No, it is not possible.
Which communication and navigation radios are operational in the Emergency Electrical Configuration with the EMER GEN powering the system?
ACP 1 and 2, VHF 1, HF, RMP 1, VOR 1, and ILS 1.
VHF 1, RMP 1, VOR 1.
RMP #1 & #2, VHF #1, HF (if equipped), ACP #1, VOR #1 and ILS #1.
All radios are lost.
Which condition will automatically illuminate the escape lights?
AC ESS SHED bus not powered.
Loss of power to the AC bus 1.
DC ESS BUS not powered.
DC ESS SHED bus not powered.
What is the meaning of the green AVAIL light?
External power is plugged in and parameters are normal. You must push the external power to connect it
External power is available to the batteries only.
The external power panel door has been opened
External power is supplying the aircraft systems
What does the blue EXT PWR ON light mean?
External power is plugged in and parameters are normal
External power is supplying the aircraft’s electrical system.
There is a fault with the external power.
If EXTERNAL power is available and within limits:
It will automatically close the bus tie contactors’s when connected by the ground crew.
The green AVAIL light will illuminate on the EXT PWR push button.
The BUS TIE push button illuminates.
Is it possible to determine the source of power for aircraft busses
It is indicated on the electrical schematic overhead.
No it is not possible.
Yes, press the ECAM ELEC push button and view the electrical schematic on the ECAM
Only when operating in the Emergency Electrical Configuration.
Both batteries are charged by the external power unit. Approximately how long does the charging process take?
10 minutes.
20 minutes.
30 minutes.
Between 30 and 45 minutes.
While operating on Emergency Electrical Power (EMER GEN powering the system), the crew should accomplish which of the following prior to lowering the landing gear?
Ensure the RAT is deployed and electrical power is stable
Activate the alternate hydraulic system
Switch to manual gear extension
Verify cabin pressure is within limits
The GALLEY FAULT light illuminates when any generator is exceeding 80% of its rated output.
True.
False.
If the source of power for the ESS AC bus is lost, does another source of power automatically power the bus?
Yes, transfer is automatic.
Yes, only if AUTO was selected on the AC ESS FEED push button.
No, this must be done by the crew.
What would cause the GALLEY fault light to illuminate?
The flight attendants have all the coffee makers and ovens on at once.
The Main Galley has shed.
The load on any generator is above 100% of its rated output.
The Aft Galley has shed.
While operating on Emergency Electrical Power (EMER GEN powering the system), how is it possible to properly complete the ECAM checklist with only an upper display?
Depress and hold the specific ECAM page push button on the ECAM control panel.
Transfer occurs automatically.
This is not possible. Use the cockpit operating manual.
After IDG disconnection why do you get a GALLEY SHED indication on the SD?
It is a reminder to push the GALLEY pushbutton to manually shed the main galley.
It is a reminder to get the flight attendants to switch off galley equipment to decrease the load on the remaining generator.
It is a reminder that the main galley has been shed automatically following the loss of one generator.
Which busses will be powered after the RAT is extended and the EMER GEN begins producing power?
BATT HOT busses, ESS DC, ESS DC SHED, ESS AC and ESS AC SHED.
The STATIC INVERTER would power both HOT BATT busses, ESS DC and ESS AC through the ESS AC SHED busses.
The BATTERIES would power both HOT BATT busses, ESS DC and ESS AC through the STATIC INVERTER.
ESS DC, ESS DC SHED, ESS AC and ESS AC SHED.
Engine #1 has just been started and the APU is inoperative. The EXT PWR push button blue ON light is illuminated. Which of the statements below is correct?
External power is supplying all electrical needs.
Engine Gen #1 is supplying AC bus #1 and the downstream systems, and AC bus #2 through the bus tie contactors.
Gen #1 supplies AC bus #1 and (generally) the downstream systems; Ext power supplies AC bus #2 .
In cruise, you have suddenly a Master Warning and caution comes on with ELEC EMER CONFIG and APP OFF. You notice a red FAULT light on the RAT & EMER GEN pushbutton. What do you think of this indication?
The EMER GEN is not yet supplying the system.
The RAT has failed. You will have to turn the batteries to ON.
The FAULT light is always on when are in ELEC EMER CONFIG.
The RAT has failed, you have to try to reconnect both IDG’s.
When are the Essential Shed buses powered by the battery?
Never. The purpose of the shed buses is to reduce the load on the batteries.
In case of double generator failure.
After every IDG connection
The AC Essential bus is powered by the battery at speed above 50 kt.
True
False
In normal electrical configuration, how is DC ESS bus supplied:
From TR 1 via DC Bus 1 and DC Bat Bus
From ESS TR
From TR 2
From Bat 2
What happens in case of total loss of main generators?
The RAT is automatically extended and powers the yellow system which drives the emergency generator
The RAT is automatically extended and powers the blue system which drives the emergency generator
The RAT has to be manually extended
The RAT is extended and mechanically connected to the emergency generator.
DC Bat Bus can be supplied by:
DC Bus 1 or batteries
DC Bus 1, DC Bus 2 or batteries
DC Bus 2 or batteries
DC Bus 1 only
Normal minimum battery voltage before APU start is:
No minimum
27.5 Volts
25.5 Volts
22.5 Volts
When disconnecting the IDG, the button should be pressed:
for longer than 3 seconds
For no more than 3 seconds
No more than 5 seconds
Until the fault light goes out
For how long should the fault light be pressed?
For no more than 5 seconds
Until the fault light goes out
For longer than 3 seconds
For no more than 3 seconds
Where can the battery voltage be checked?
On the ECAM elec. Page only
On the elec. overhead panel and ECAM E/WD
On the elec. overhead panel only
On the elec. overhead panel and ECAM elec. Page
In flight on batteries only, the AC ESS Shed bus and DC ESS Shed bus are lost.
Yes
No
Only A/C ESS Shed Bus is lost
Only D/C ESS Shed Bus is lost
The static inverter works:
Always
When aircraft speed is > 50 kt and on batteries only.
When one main generator fails
Only when generator 2 fails
If a TR fails:
The other TR automatically replaces the faulty one and the ESS TR supplies the DC Ess Bus
The static inverter replaces the faulty TR
The DC Bus on the faulty side is lost
In flight in case of loss of all main generators, emergency generator not running, the DC ESS Bus is supplied by:
Hot bus 2
ESS TR
Hot Bus and ESS TR
Hot Bus 1
If AC Bus 1 fails the AC ESS bus is supplied by:
Emer Gen.
The RAT
Static Inverter
AC Bus 2